Storage Coefficient given Rate of Change of Volume Solution

STEP 0: Pre-Calculation Summary
Formula Used
Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area)
S = δVδt/(-(-δhδt)*Aaq)
This formula uses 4 Variables
Variables Used
Storage Coefficient - Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Rate of Change of Volume - (Measured in Cubic Centimeter per Second) - Rate of Change of Volume is the ratio of change in volume to change in time.
Rate of Change of Height - (Measured in Meter per Second) - Rate of Change of Height is the ratio of change in height to change in time.
Aquifer Area - (Measured in Square Meter) - Aquifer Area is the saturated area beneath the water table.
STEP 1: Convert Input(s) to Base Unit
Rate of Change of Volume: 0.92 Cubic Centimeter per Second --> 0.92 Cubic Centimeter per Second No Conversion Required
Rate of Change of Height: 0.05 Meter per Second --> 0.05 Meter per Second No Conversion Required
Aquifer Area: 15.33 Square Meter --> 15.33 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
S = δVδt/(-(-δhδt)*Aaq) --> 0.92/(-(-0.05)*15.33)
Evaluating ... ...
S = 1.20026092628832
STEP 3: Convert Result to Output's Unit
1.20026092628832 --> No Conversion Required
FINAL ANSWER
1.20026092628832 1.200261 <-- Storage Coefficient
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Storage Coefficient Calculators

Storage Coefficient given Radius of Elementary Cylinder
​ LaTeX ​ Go Storage Coefficient = Rate of Change of Volume/(-(-2*pi*Radius of Elementary Cylinder*Change in Radius of Elementary Cylinder*Rate of Change of Height))
Storage Coefficient given Rate of Change of Volume
​ LaTeX ​ Go Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area)

Storage Coefficient given Rate of Change of Volume Formula

​LaTeX ​Go
Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area)
S = δVδt/(-(-δhδt)*Aaq)

What is Aquifer?

An aquifer is a body of rock and/or sediment that holds groundwater. Groundwater is the word used to describe precipitation that has infiltrated the soil beyond the surface and collected in empty spaces underground.

How to Calculate Storage Coefficient given Rate of Change of Volume?

Storage Coefficient given Rate of Change of Volume calculator uses Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area) to calculate the Storage Coefficient, Storage Coefficient given Rate of Change of Volume formula is defined as a dimensionless quantity that characterizes the ability of an aquifer to release or absorb water in response to changes in head, providing valuable insights into the aquifer's properties and behavior during unsteady flow conditions. Storage Coefficient is denoted by S symbol.

How to calculate Storage Coefficient given Rate of Change of Volume using this online calculator? To use this online calculator for Storage Coefficient given Rate of Change of Volume, enter Rate of Change of Volume (δVδt), Rate of Change of Height (δhδt) & Aquifer Area (Aaq) and hit the calculate button. Here is how the Storage Coefficient given Rate of Change of Volume calculation can be explained with given input values -> 1.200261 = 9.2E-07/(-(-0.05)*15.33).

FAQ

What is Storage Coefficient given Rate of Change of Volume?
Storage Coefficient given Rate of Change of Volume formula is defined as a dimensionless quantity that characterizes the ability of an aquifer to release or absorb water in response to changes in head, providing valuable insights into the aquifer's properties and behavior during unsteady flow conditions and is represented as S = δVδt/(-(-δhδt)*Aaq) or Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area). Rate of Change of Volume is the ratio of change in volume to change in time, Rate of Change of Height is the ratio of change in height to change in time & Aquifer Area is the saturated area beneath the water table.
How to calculate Storage Coefficient given Rate of Change of Volume?
Storage Coefficient given Rate of Change of Volume formula is defined as a dimensionless quantity that characterizes the ability of an aquifer to release or absorb water in response to changes in head, providing valuable insights into the aquifer's properties and behavior during unsteady flow conditions is calculated using Storage Coefficient = Rate of Change of Volume/(-(-Rate of Change of Height)*Aquifer Area). To calculate Storage Coefficient given Rate of Change of Volume, you need Rate of Change of Volume (δVδt), Rate of Change of Height (δhδt) & Aquifer Area (Aaq). With our tool, you need to enter the respective value for Rate of Change of Volume, Rate of Change of Height & Aquifer Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Storage Coefficient?
In this formula, Storage Coefficient uses Rate of Change of Volume, Rate of Change of Height & Aquifer Area. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Storage Coefficient = Rate of Change of Volume/(-(-2*pi*Radius of Elementary Cylinder*Change in Radius of Elementary Cylinder*Rate of Change of Height))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!