Starting Time for Induction Motor under No Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
Starting Time For Induction motor on No Load = (-Mechanical Time Constant of Motor/2)*int((Slip/Slip at Maximum Torque+Slip at Maximum Torque/Slip)*x,x,1,0.05)
ts = (-τm/2)*int((s/sm+sm/s)*x,x,1,0.05)
This formula uses 1 Functions, 4 Variables
Functions Used
int - The definite integral can be used to calculate net signed area, which is the area above the x -axis minus the area below the x -axis., int(expr, arg, from, to)
Variables Used
Starting Time For Induction motor on No Load - (Measured in Second) - The Starting Time for Induction Motor on No Load is the duration required for the motor to accelerate from standstill to its rated speed when no mechanical load is applied to the motor shaft.
Mechanical Time Constant of Motor - (Measured in Second) - Mechanical Time Constant of Motor is defined as the time taken by motor to reach its synchronous speed from standstill under constant accelerating torque equal to the maximum torque of the motor.
Slip - Slip energy recovery is one of the methods of controlling the speed of an induction motor.
Slip at Maximum Torque - Slip at Maximum Torque refers to the slip value at which the motor produces its highest torque while still maintaining a stable operating condition.
STEP 1: Convert Input(s) to Base Unit
Mechanical Time Constant of Motor: 2.359 Second --> 2.359 Second No Conversion Required
Slip: 0.83 --> No Conversion Required
Slip at Maximum Torque: 0.67 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ts = (-τm/2)*int((s/sm+sm/s)*x,x,1,0.05) --> (-2.359/2)*int((0.83/0.67+0.67/0.83)*x,x,1,0.05)
Evaluating ... ...
ts = 1.2036324512228
STEP 3: Convert Result to Output's Unit
1.2036324512228 Second --> No Conversion Required
FINAL ANSWER
1.2036324512228 1.203632 Second <-- Starting Time For Induction motor on No Load
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Siddharth Raj
Heritage Institute of Technology ( HITK), Kolkata
Siddharth Raj has created this Calculator and 10+ more calculators!
Verifier Image
Verified by Dipanjona Mallick
Heritage Insitute of technology (HITK), Kolkata
Dipanjona Mallick has verified this Calculator and 50+ more calculators!

Electric Traction Drives Calculators

Torque of Squirrel Cage Induction Motor
​ LaTeX ​ Go Torque = (Constant*Voltage^2*Rotor Resistance)/((Stator Resistance+Rotor Resistance)^2+(Stator Reactance+Rotor Reactance)^2)
DC Output Voltage of Rectifier in Scherbius Drive Given Rotor RMS Line Voltage
​ LaTeX ​ Go DC Voltage = (3*sqrt(2))*(RMS Value of Rotor Side Line Voltage/pi)
DC Output Voltage of Rectifier in Scherbius Drive Given Maximum Rotor Voltage
​ LaTeX ​ Go DC Voltage = 3*(Peak Voltage/pi)
DC Output Voltage of Rectifier in Scherbius Drive Given Rotor RMS Line Voltage at Slip
​ LaTeX ​ Go DC Voltage = 1.35*Rotor RMS Line Voltage with Slip

Starting Time for Induction Motor under No Load Formula

​LaTeX ​Go
Starting Time For Induction motor on No Load = (-Mechanical Time Constant of Motor/2)*int((Slip/Slip at Maximum Torque+Slip at Maximum Torque/Slip)*x,x,1,0.05)
ts = (-τm/2)*int((s/sm+sm/s)*x,x,1,0.05)

How does the Starting Time of an Induction Motor on No Load differs under Load Conditions?

The starting time of an induction motor on no load is typically shorter than its starting time under loaded conditions. This is because there is minimal resistance to the rotor's motion when starting on no load, allowing the motor to reach its rated speed more quickly. Conversely, starting under loaded conditions involves additional inertia and mechanical resistance, requiring more torque and time to overcome the load and reach the rated speed.


How to Calculate Starting Time for Induction Motor under No Load?

Starting Time for Induction Motor under No Load calculator uses Starting Time For Induction motor on No Load = (-Mechanical Time Constant of Motor/2)*int((Slip/Slip at Maximum Torque+Slip at Maximum Torque/Slip)*x,x,1,0.05) to calculate the Starting Time For Induction motor on No Load, The Starting Time for Induction Motor under No Load refers to the duration it takes for the motor to accelerate from rest to its rated speed when there is no mechanical load applied to the shaft. It characterizes the time required for the motor to reach its operating speed under no load conditions. Starting Time For Induction motor on No Load is denoted by ts symbol.

How to calculate Starting Time for Induction Motor under No Load using this online calculator? To use this online calculator for Starting Time for Induction Motor under No Load, enter Mechanical Time Constant of Motor m), Slip (s) & Slip at Maximum Torque (sm) and hit the calculate button. Here is how the Starting Time for Induction Motor under No Load calculation can be explained with given input values -> 1.203632 = (-2.359/2)*int((0.83/0.67+0.67/0.83)*x,x,1,0.05).

FAQ

What is Starting Time for Induction Motor under No Load?
The Starting Time for Induction Motor under No Load refers to the duration it takes for the motor to accelerate from rest to its rated speed when there is no mechanical load applied to the shaft. It characterizes the time required for the motor to reach its operating speed under no load conditions and is represented as ts = (-τm/2)*int((s/sm+sm/s)*x,x,1,0.05) or Starting Time For Induction motor on No Load = (-Mechanical Time Constant of Motor/2)*int((Slip/Slip at Maximum Torque+Slip at Maximum Torque/Slip)*x,x,1,0.05). Mechanical Time Constant of Motor is defined as the time taken by motor to reach its synchronous speed from standstill under constant accelerating torque equal to the maximum torque of the motor, Slip energy recovery is one of the methods of controlling the speed of an induction motor & Slip at Maximum Torque refers to the slip value at which the motor produces its highest torque while still maintaining a stable operating condition.
How to calculate Starting Time for Induction Motor under No Load?
The Starting Time for Induction Motor under No Load refers to the duration it takes for the motor to accelerate from rest to its rated speed when there is no mechanical load applied to the shaft. It characterizes the time required for the motor to reach its operating speed under no load conditions is calculated using Starting Time For Induction motor on No Load = (-Mechanical Time Constant of Motor/2)*int((Slip/Slip at Maximum Torque+Slip at Maximum Torque/Slip)*x,x,1,0.05). To calculate Starting Time for Induction Motor under No Load, you need Mechanical Time Constant of Motor m), Slip (s) & Slip at Maximum Torque (sm). With our tool, you need to enter the respective value for Mechanical Time Constant of Motor, Slip & Slip at Maximum Torque and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!