Specific Capacity per unit Well Area for Discharge from Open Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Specific Capacity = Flow Discharge/(Area of the Well*Depression Head)
Ks = Qf/(A*H)
This formula uses 4 Variables
Variables Used
Specific Capacity - The Specific Capacity is referred as amount of water furnished under a standard unit head.
Flow Discharge - (Measured in Cubic Meter per Second) - The Flow Discharge refers to the volume of water passing through a particular cross-section of a river or stream per unit of time. It is typically measured in (m³/s) or cubic feet per second (cfs).
Area of the Well - (Measured in Square Meter) - The Area of the Well is referred as land area around a well that is influenced by pumping.
Depression Head - (Measured in Meter) - The Depression Head is defined as height of the bottom of a well above the datum.
STEP 1: Convert Input(s) to Base Unit
Flow Discharge: 30 Cubic Meter per Second --> 30 Cubic Meter per Second No Conversion Required
Area of the Well: 20 Square Meter --> 20 Square Meter No Conversion Required
Depression Head: 7 Meter --> 7 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ks = Qf/(A*H) --> 30/(20*7)
Evaluating ... ...
Ks = 0.214285714285714
STEP 3: Convert Result to Output's Unit
0.214285714285714 --> No Conversion Required
FINAL ANSWER
0.214285714285714 0.214286 <-- Specific Capacity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

Recuperation Test Calculators

Proportionality Constant per unit Well Area of Aquifer
​ LaTeX ​ Go Proportionality Constant = Area of the Well*((1/Time Interval)*ln(Drawdown at the Start of Recuperation/Drawdown at a Time))
Equation for Time Interval
​ LaTeX ​ Go Time Interval = (Area of the Well/Proportionality Constant)*ln(Drawdown at the Start of Recuperation/Drawdown at a Time)
Area of Well given Time Interval
​ LaTeX ​ Go Area of the Well = Proportionality Constant*Time Interval/ln(Drawdown at the Start of Recuperation/Drawdown at a Time)
Discharge from Open Well under Depression Head
​ LaTeX ​ Go Yield from an Open Well = Specific Capacity*Area of the Well*Depression Head

Specific Capacity per unit Well Area for Discharge from Open Well Formula

​LaTeX ​Go
Specific Capacity = Flow Discharge/(Area of the Well*Depression Head)
Ks = Qf/(A*H)

What is Discharge In Hydrology?

Discharge is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material in addition to the water itself.

How to Calculate Specific Capacity per unit Well Area for Discharge from Open Well?

Specific Capacity per unit Well Area for Discharge from Open Well calculator uses Specific Capacity = Flow Discharge/(Area of the Well*Depression Head) to calculate the Specific Capacity, The Specific Capacity per unit Well Area for Discharge from Open Well formula is defined as an essential parameter of the aquifer representing discharge per unit drawdown. Specific Capacity is denoted by Ks symbol.

How to calculate Specific Capacity per unit Well Area for Discharge from Open Well using this online calculator? To use this online calculator for Specific Capacity per unit Well Area for Discharge from Open Well, enter Flow Discharge (Qf), Area of the Well (A) & Depression Head (H) and hit the calculate button. Here is how the Specific Capacity per unit Well Area for Discharge from Open Well calculation can be explained with given input values -> 0.214286 = 30/(20*7).

FAQ

What is Specific Capacity per unit Well Area for Discharge from Open Well?
The Specific Capacity per unit Well Area for Discharge from Open Well formula is defined as an essential parameter of the aquifer representing discharge per unit drawdown and is represented as Ks = Qf/(A*H) or Specific Capacity = Flow Discharge/(Area of the Well*Depression Head). The Flow Discharge refers to the volume of water passing through a particular cross-section of a river or stream per unit of time. It is typically measured in (m³/s) or cubic feet per second (cfs), The Area of the Well is referred as land area around a well that is influenced by pumping & The Depression Head is defined as height of the bottom of a well above the datum.
How to calculate Specific Capacity per unit Well Area for Discharge from Open Well?
The Specific Capacity per unit Well Area for Discharge from Open Well formula is defined as an essential parameter of the aquifer representing discharge per unit drawdown is calculated using Specific Capacity = Flow Discharge/(Area of the Well*Depression Head). To calculate Specific Capacity per unit Well Area for Discharge from Open Well, you need Flow Discharge (Qf), Area of the Well (A) & Depression Head (H). With our tool, you need to enter the respective value for Flow Discharge, Area of the Well & Depression Head and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.