Solids Processed given Actual Solid Loading Rate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Solid Processed = (Solid Loading Rate*Surface Area)
Sp = (SLr*SA)
This formula uses 3 Variables
Variables Used
Solid Processed - (Measured in Kilogram per Second) - Solid Processed is the total quantity or volume of solids treated, settled, or removed from the wastewater over a specific period, typically measured in kilograms, tons, or cubic meters.
Solid Loading Rate - (Measured in Kilogram per Second Square Meter) - Solid Loading Rate is the amount of solids applied per unit area of a treatment process, such as a clarifier, typically measured in kilograms per square meter per day (kg/m²/day).
Surface Area - (Measured in Square Meter) - Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
STEP 1: Convert Input(s) to Base Unit
Solid Loading Rate: 20 kilogram per Day Square Meter --> 0.000231481481481481 Kilogram per Second Square Meter (Check conversion ​here)
Surface Area: 4 Square Meter --> 4 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Sp = (SLr*SA) --> (0.000231481481481481*4)
Evaluating ... ...
Sp = 0.000925925925925924
STEP 3: Convert Result to Output's Unit
0.000925925925925924 Kilogram per Second -->79.9999999999998 Kilogram per Day (Check conversion ​here)
FINAL ANSWER
79.9999999999998 80 Kilogram per Day <-- Solid Processed
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Design of a Circular Settling Tank Calculators

Design Surface Loading Rate given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Loading Rate = (Peak Discharge/Surface Area)
Peak Discharge given Surface Area of Circular Settling Tank
​ LaTeX ​ Go Peak Discharge = (Surface Area*Surface Loading Rate)
Surface Area of Circular Settling Tank
​ LaTeX ​ Go Surface Area = (Peak Discharge/Surface Loading Rate)
Peak Discharge in Circular Settling Tanks
​ LaTeX ​ Go Peak Discharge = Average Daily Load*Peaking Factor

Solids Processed given Actual Solid Loading Rate Formula

​LaTeX ​Go
Solid Processed = (Solid Loading Rate*Surface Area)
Sp = (SLr*SA)

What is Solids Loading Rate?

Solids Loading Rate (SLR) SLR is the number of solids per day that can be removed per square foot of surface area by a clarifier (lbs/day/ft²).

How to Calculate Solids Processed given Actual Solid Loading Rate?

Solids Processed given Actual Solid Loading Rate calculator uses Solid Processed = (Solid Loading Rate*Surface Area) to calculate the Solid Processed, The Solids Processed given Actual Solid Loading Rate is defined as the total quantity or volume of solids that have been treated, settled, or removed from the wastewater over a specific period, typically measured in units such as kilograms, tons, or cubic meters. Solid Processed is denoted by Sp symbol.

How to calculate Solids Processed given Actual Solid Loading Rate using this online calculator? To use this online calculator for Solids Processed given Actual Solid Loading Rate, enter Solid Loading Rate (SLr) & Surface Area (SA) and hit the calculate button. Here is how the Solids Processed given Actual Solid Loading Rate calculation can be explained with given input values -> 6.9E+6 = (0.000231481481481481*4).

FAQ

What is Solids Processed given Actual Solid Loading Rate?
The Solids Processed given Actual Solid Loading Rate is defined as the total quantity or volume of solids that have been treated, settled, or removed from the wastewater over a specific period, typically measured in units such as kilograms, tons, or cubic meters and is represented as Sp = (SLr*SA) or Solid Processed = (Solid Loading Rate*Surface Area). Solid Loading Rate is the amount of solids applied per unit area of a treatment process, such as a clarifier, typically measured in kilograms per square meter per day (kg/m²/day) & Surface Area is the horizontal area available for sedimentation, impacting the tank's capacity to separate solids, typically measured in square meters (m²).
How to calculate Solids Processed given Actual Solid Loading Rate?
The Solids Processed given Actual Solid Loading Rate is defined as the total quantity or volume of solids that have been treated, settled, or removed from the wastewater over a specific period, typically measured in units such as kilograms, tons, or cubic meters is calculated using Solid Processed = (Solid Loading Rate*Surface Area). To calculate Solids Processed given Actual Solid Loading Rate, you need Solid Loading Rate (SLr) & Surface Area (SA). With our tool, you need to enter the respective value for Solid Loading Rate & Surface Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!