Short Circuit Current given Fill Factor of Cell Solution

STEP 0: Pre-Calculation Summary
Formula Used
Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell)
Isc = (Im*Vm)/(Voc*FF)
This formula uses 5 Variables
Variables Used
Short Circuit Current in Solar cell - (Measured in Ampere) - Short Circuit Current in Solar Cell is the current through the solar cell when the voltage across the solar cell is zero.
Current at Maximum Power - (Measured in Ampere) - Current at Maximum Power is the current at which maximum power occurs .
Voltage at Maximum Power - (Measured in Volt) - Voltage at Maximum Power is the voltage at which maximum power occurs.
Open Circuit Voltage - (Measured in Volt) - Open Circuit Voltage is the difference of electrical potential between two terminals of a device when disconnected from any circuit. There is no external load connected.
Fill Factor of Solar Cell - Fill Factor of Solar Cell is a measure of how closely the I-V characteristic of the cell approaches being a rectangle.
STEP 1: Convert Input(s) to Base Unit
Current at Maximum Power: 0.11 Ampere --> 0.11 Ampere No Conversion Required
Voltage at Maximum Power: 0.41 Volt --> 0.41 Volt No Conversion Required
Open Circuit Voltage: 0.191 Volt --> 0.191 Volt No Conversion Required
Fill Factor of Solar Cell: 0.0029 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Isc = (Im*Vm)/(Voc*FF) --> (0.11*0.41)/(0.191*0.0029)
Evaluating ... ...
Isc = 81.4226394656075
STEP 3: Convert Result to Output's Unit
81.4226394656075 Ampere --> No Conversion Required
FINAL ANSWER
81.4226394656075 81.42264 Ampere <-- Short Circuit Current in Solar cell
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by ADITYA RAWAT
DIT UNIVERSITY (DITU), Dehradun
ADITYA RAWAT has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Photovoltaic Conversion Calculators

Load current in Solar cell
​ LaTeX ​ Go Load Current in Solar cell = Short Circuit Current in Solar cell-(Reverse Saturation Current*(e^(([Charge-e]*Voltage in Solar cell)/(Ideality Factor in Solar Cells*[BoltZ]*Temperature in Kelvin))-1))
Short Circuit Current given Fill Factor of Cell
​ LaTeX ​ Go Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell)
Fill Factor of Cell
​ LaTeX ​ Go Fill Factor of Solar Cell = (Current at Maximum Power*Voltage at Maximum Power)/(Short Circuit Current in Solar cell*Open Circuit Voltage)
Voltage given Fill Factor of Cell
​ LaTeX ​ Go Voltage at Maximum Power = (Fill Factor of Solar Cell*Short Circuit Current in Solar cell*Open Circuit Voltage)/Current at Maximum Power

Short Circuit Current given Fill Factor of Cell Formula

​LaTeX ​Go
Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell)
Isc = (Im*Vm)/(Voc*FF)

How are Solar Cells used in Real Life?

Solar energy from photovoltaic cells is used for commercial power generation, road signs, calculators, satellites, and in many other applications. Rooftop collectors use solar power to directly heat water without converting it to electricity first.

How to Calculate Short Circuit Current given Fill Factor of Cell?

Short Circuit Current given Fill Factor of Cell calculator uses Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell) to calculate the Short Circuit Current in Solar cell, Short Circuit Current given Fill Factor of Cell formula is defined as a measure of the maximum current that can be drawn from a photovoltaic cell under short-circuit conditions, which is influenced by the maximum power point, open-circuit voltage, and fill factor of the cell. Short Circuit Current in Solar cell is denoted by Isc symbol.

How to calculate Short Circuit Current given Fill Factor of Cell using this online calculator? To use this online calculator for Short Circuit Current given Fill Factor of Cell, enter Current at Maximum Power (Im), Voltage at Maximum Power (Vm), Open Circuit Voltage (Voc) & Fill Factor of Solar Cell (FF) and hit the calculate button. Here is how the Short Circuit Current given Fill Factor of Cell calculation can be explained with given input values -> 181.6351 = (0.11*0.41)/(0.191*0.0029).

FAQ

What is Short Circuit Current given Fill Factor of Cell?
Short Circuit Current given Fill Factor of Cell formula is defined as a measure of the maximum current that can be drawn from a photovoltaic cell under short-circuit conditions, which is influenced by the maximum power point, open-circuit voltage, and fill factor of the cell and is represented as Isc = (Im*Vm)/(Voc*FF) or Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell). Current at Maximum Power is the current at which maximum power occurs , Voltage at Maximum Power is the voltage at which maximum power occurs, Open Circuit Voltage is the difference of electrical potential between two terminals of a device when disconnected from any circuit. There is no external load connected & Fill Factor of Solar Cell is a measure of how closely the I-V characteristic of the cell approaches being a rectangle.
How to calculate Short Circuit Current given Fill Factor of Cell?
Short Circuit Current given Fill Factor of Cell formula is defined as a measure of the maximum current that can be drawn from a photovoltaic cell under short-circuit conditions, which is influenced by the maximum power point, open-circuit voltage, and fill factor of the cell is calculated using Short Circuit Current in Solar cell = (Current at Maximum Power*Voltage at Maximum Power)/(Open Circuit Voltage*Fill Factor of Solar Cell). To calculate Short Circuit Current given Fill Factor of Cell, you need Current at Maximum Power (Im), Voltage at Maximum Power (Vm), Open Circuit Voltage (Voc) & Fill Factor of Solar Cell (FF). With our tool, you need to enter the respective value for Current at Maximum Power, Voltage at Maximum Power, Open Circuit Voltage & Fill Factor of Solar Cell and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Short Circuit Current in Solar cell?
In this formula, Short Circuit Current in Solar cell uses Current at Maximum Power, Voltage at Maximum Power, Open Circuit Voltage & Fill Factor of Solar Cell. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Short Circuit Current in Solar cell = Load Current in Solar cell+(Reverse Saturation Current*(e^(([Charge-e]*Voltage in Solar cell)/(Ideality Factor in Solar Cells*[BoltZ]*Temperature in Kelvin))-1))
  • Short Circuit Current in Solar cell = (Power of Photovoltaic Cell/Voltage in Solar cell)+(Reverse Saturation Current*(e^(([Charge-e]*Voltage in Solar cell)/([BoltZ]*Temperature in Kelvin))-1))
  • Short Circuit Current in Solar cell = (Maximum Power Output of Cell*((1+([Charge-e]*Voltage at Maximum Power)/([BoltZ]*Temperature in Kelvin))/(([Charge-e]*Voltage at Maximum Power^2)/([BoltZ]*Temperature in Kelvin))))-Reverse Saturation Current
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!