Sewage Flow Rate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration)
Qs = ((CR-C)*Qstream)/(C-Cs)
This formula uses 5 Variables
Variables Used
Sewage Discharge - (Measured in Cubic Meter per Second) - Sewage discharge is the flow rate of sewage when it is being discharged in the river.
River Concentration - River Concentration is the concentration of river parameters like bod, do etc.
Mixing Concentration - Mixing Concentration is the concentration obtained after sewage gets mixed in the river stream.
Discharge in Stream - (Measured in Cubic Meter per Second) - Discharge in Stream referred as the volumetric flow rate of water that is transported through a given cross-sectional area.
Sewage Concentration - Sewage Concentration refers to the concentration of various constituents in wastewater, including organic and inorganic substances, suspended solids, nutrients, pathogens, and other contaminants.
STEP 1: Convert Input(s) to Base Unit
River Concentration: 1.3 --> No Conversion Required
Mixing Concentration: 1.2 --> No Conversion Required
Discharge in Stream: 100 Cubic Meter per Second --> 100 Cubic Meter per Second No Conversion Required
Sewage Concentration: 0.2 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qs = ((CR-C)*Qstream)/(C-Cs) --> ((1.3-1.2)*100)/(1.2-0.2)
Evaluating ... ...
Qs = 10
STEP 3: Convert Result to Output's Unit
10 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
10 Cubic Meter per Second <-- Sewage Discharge
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Disposing of the Sewage Effluents Calculators

River Stream Flow Rate
​ LaTeX ​ Go Discharge in Stream = ((Sewage Concentration*Sewage Discharge)-(Mixing Concentration*Sewage Discharge))/(Mixing Concentration-River Concentration)
River Stream Concentration
​ LaTeX ​ Go River Concentration = (Mixing Concentration*(Sewage Discharge+Discharge in Stream)-(Sewage Concentration*Sewage Discharge))/Discharge in Stream
Sewage Concentration
​ LaTeX ​ Go Sewage Concentration = (Mixing Concentration*(Sewage Discharge+Discharge in Stream)-(River Concentration*Discharge in Stream))/Sewage Discharge
Sewage Flow Rate
​ LaTeX ​ Go Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration)

Sewage Flow Rate Formula

​LaTeX ​Go
Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration)
Qs = ((CR-C)*Qstream)/(C-Cs)

What is Discharge?

Discharge referred as the amount of depth of water flow out from the river or reservoir in mm or liters with respect to time.

How to Calculate Sewage Flow Rate?

Sewage Flow Rate calculator uses Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration) to calculate the Sewage Discharge, The Sewage Flow Rate formula is defined as the volume of sewage passing through a system per unit time, usually expressed in liters per second (L/s), cubic meters per hour (m³/h), or million gallons per day (MGD). Sewage Discharge is denoted by Qs symbol.

How to calculate Sewage Flow Rate using this online calculator? To use this online calculator for Sewage Flow Rate, enter River Concentration (CR), Mixing Concentration (C), Discharge in Stream (Qstream) & Sewage Concentration (Cs) and hit the calculate button. Here is how the Sewage Flow Rate calculation can be explained with given input values -> 6 = ((1.3-1.2)*100)/(1.2-0.2).

FAQ

What is Sewage Flow Rate?
The Sewage Flow Rate formula is defined as the volume of sewage passing through a system per unit time, usually expressed in liters per second (L/s), cubic meters per hour (m³/h), or million gallons per day (MGD) and is represented as Qs = ((CR-C)*Qstream)/(C-Cs) or Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration). River Concentration is the concentration of river parameters like bod, do etc, Mixing Concentration is the concentration obtained after sewage gets mixed in the river stream, Discharge in Stream referred as the volumetric flow rate of water that is transported through a given cross-sectional area & Sewage Concentration refers to the concentration of various constituents in wastewater, including organic and inorganic substances, suspended solids, nutrients, pathogens, and other contaminants.
How to calculate Sewage Flow Rate?
The Sewage Flow Rate formula is defined as the volume of sewage passing through a system per unit time, usually expressed in liters per second (L/s), cubic meters per hour (m³/h), or million gallons per day (MGD) is calculated using Sewage Discharge = ((River Concentration-Mixing Concentration)*Discharge in Stream)/(Mixing Concentration-Sewage Concentration). To calculate Sewage Flow Rate, you need River Concentration (CR), Mixing Concentration (C), Discharge in Stream (Qstream) & Sewage Concentration (Cs). With our tool, you need to enter the respective value for River Concentration, Mixing Concentration, Discharge in Stream & Sewage Concentration and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.