Sewage Flow given MLSS Solution

STEP 0: Pre-Calculation Summary
Formula Used
Sewage Flow = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD)
Q = (BOD*X*V)/(Mt*Qi)
This formula uses 6 Variables
Variables Used
Sewage Flow - (Measured in Cubic Meter) - Sewage Flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
Daily BOD - (Measured in Kilogram) - Daily BOD load measures the amount of oxygen that microorganisms will consume while decomposing organic matter in a water sample over a 24-hour period.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process.
Volume of Tank - (Measured in Cubic Meter) - Volume of Tank is defined as the capacity of flocculation and mixing tank.
Total Microbial Mass - (Measured in Kilogram) - Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes.
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
STEP 1: Convert Input(s) to Base Unit
Daily BOD: 3 Milligram --> 3E-06 Kilogram (Check conversion ​here)
MLSS: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion ​here)
Volume of Tank: 1.5 Cubic Meter --> 1.5 Cubic Meter No Conversion Required
Total Microbial Mass: 3 Gram --> 0.003 Kilogram (Check conversion ​here)
Influent BOD: 0.0009 Milligram per Liter --> 9E-07 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = (BOD*X*V)/(Mt*Qi) --> (3E-06*0.002*1.5)/(0.003*9E-07)
Evaluating ... ...
Q = 3.33333333333333
STEP 3: Convert Result to Output's Unit
3.33333333333333 Cubic Meter --> No Conversion Required
FINAL ANSWER
3.33333333333333 3.333333 Cubic Meter <-- Sewage Flow
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Food is to Microorganism Ratio or F is to M Ratio Calculators

BOD Load applied to Aeration System
​ Go BOD Load applied to Aeration System = Sewage Flow*Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
​ Go Total Microbial Mass = Daily BOD/Food to Microorganism Ratio
Daily BOD Load given Food to Microorganism Ratio
​ Go Daily BOD = Food to Microorganism Ratio*Total Microbial Mass
Food to Microorganism Ratio
​ Go Food to Microorganism Ratio = Daily BOD/Total Microbial Mass

Sewage Flow given MLSS Formula

Sewage Flow = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD)
Q = (BOD*X*V)/(Mt*Qi)

What is Sewage?

Sewage, or domestic/municipal wastewater, is a type of wastewater that is produced by a community of people. ... Sewage usually travels from a building's plumbing either into a sewer, which will carry it elsewhere, or into an onsite sewage facility (of which there are many kinds).

How to Calculate Sewage Flow given MLSS?

Sewage Flow given MLSS calculator uses Sewage Flow = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD) to calculate the Sewage Flow, The Sewage Flow given MLSS formula is defined as the calculation of sewage flow when we have prior information of MLSS. Sewage Flow is denoted by Q symbol.

How to calculate Sewage Flow given MLSS using this online calculator? To use this online calculator for Sewage Flow given MLSS, enter Daily BOD (BOD), MLSS (X), Volume of Tank (V), Total Microbial Mass (Mt) & Influent BOD (Qi) and hit the calculate button. Here is how the Sewage Flow given MLSS calculation can be explained with given input values -> 20 = (3E-06*0.002*1.5)/(0.003*9E-07).

FAQ

What is Sewage Flow given MLSS?
The Sewage Flow given MLSS formula is defined as the calculation of sewage flow when we have prior information of MLSS and is represented as Q = (BOD*X*V)/(Mt*Qi) or Sewage Flow = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD). Daily BOD load measures the amount of oxygen that microorganisms will consume while decomposing organic matter in a water sample over a 24-hour period, MLSS is the concentration of suspended solids in the mixed liquor within an aeration tank during the activated sludge process, Volume of Tank is defined as the capacity of flocculation and mixing tank, Total Microbial Mass is the cumulative mass of microorganisms present in a given sample or system. This includes bacteria, fungi, protozoa, and other microbes & Influent BOD is the total amount of BOD which is present in the incoming sewage.
How to calculate Sewage Flow given MLSS?
The Sewage Flow given MLSS formula is defined as the calculation of sewage flow when we have prior information of MLSS is calculated using Sewage Flow = (Daily BOD*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD). To calculate Sewage Flow given MLSS, you need Daily BOD (BOD), MLSS (X), Volume of Tank (V), Total Microbial Mass (Mt) & Influent BOD (Qi). With our tool, you need to enter the respective value for Daily BOD, MLSS, Volume of Tank, Total Microbial Mass & Influent BOD and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Sewage Flow?
In this formula, Sewage Flow uses Daily BOD, MLSS, Volume of Tank, Total Microbial Mass & Influent BOD. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Sewage Flow = Daily BOD/Influent BOD
  • Sewage Flow = (Food to Microorganism Ratio*Volume of Tank*MLSS)/Influent BOD
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!