Service Correction Factor given Power transmitted by Synchronous Belt Solution

STEP 0: Pre-Calculation Summary
Formula Used
Service Correction Factor = Standard Capacity of Belt/Power Transmitted by Belt
Cs = Ps/Pt
This formula uses 3 Variables
Variables Used
Service Correction Factor - Service correction factor or simply service factor is defined as the ratio of maximum torque to the rated torque.
Standard Capacity of Belt - (Measured in Watt) - Standard Capacity of Belt is the power capacity of the belt from which the power needs to be transmitted to the other end.
Power Transmitted by Belt - (Measured in Watt) - Power Transmitted by Belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
STEP 1: Convert Input(s) to Base Unit
Standard Capacity of Belt: 8.38 Kilowatt --> 8380 Watt (Check conversion ​here)
Power Transmitted by Belt: 6.45 Kilowatt --> 6450 Watt (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cs = Ps/Pt --> 8380/6450
Evaluating ... ...
Cs = 1.29922480620155
STEP 3: Convert Result to Output's Unit
1.29922480620155 --> No Conversion Required
FINAL ANSWER
1.29922480620155 1.299225 <-- Service Correction Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Indian Institute of Technology (IIT (ISM) ), Dhanbad, Jharkhand
Aditya Prakash Gautam has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Synchronous Belt Drives Calculators

Transmission Ratio of Synchronous belt drive given no. of teeth in smaller and larger pulley
​ LaTeX ​ Go Transmission Ratio of Belt Drive = Number of Teeth on Larger Pulley/Number of Teeth on Smaller Pulley
Transmission Ratio of Synchronous belt drive given Speed of smaller and larger pulley
​ Go Transmission Ratio of Belt Drive = Speed of Smaller Pulley/Speed of Larger Pulley
Speed of smaller pulley given Transmission ratio of Synchronous belt drive
​ Go Speed of Smaller Pulley = Speed of Larger Pulley*Transmission Ratio of Belt Drive
Speed of larger pulley given Transmission ratio of Synchronous belt drive
​ Go Speed of Larger Pulley = Speed of Smaller Pulley/Transmission Ratio of Belt Drive

Service Correction Factor given Power transmitted by Synchronous Belt Formula

​Go
Service Correction Factor = Standard Capacity of Belt/Power Transmitted by Belt
Cs = Ps/Pt

What is the significance of Service factor ?

In practical applications, the torque developed by the source of power varies during the work cycle. Similarly, the torque required by the driven machine also varies. The two sides are balanced by means of a flywheel. In gear design, the maximum force
(due to maximum torque) is the criterion. This is
accounted by means of a service factor. The service factor is defined as the ratio of maximum torque to the rated torque.

How to Calculate Service Correction Factor given Power transmitted by Synchronous Belt?

Service Correction Factor given Power transmitted by Synchronous Belt calculator uses Service Correction Factor = Standard Capacity of Belt/Power Transmitted by Belt to calculate the Service Correction Factor, The Service Correction Factor given Power transmitted by Synchronous Belt formula is defined as the standard capacity of the belt divided by the power transmitted by the synchronous belt. Service Correction Factor is denoted by Cs symbol.

How to calculate Service Correction Factor given Power transmitted by Synchronous Belt using this online calculator? To use this online calculator for Service Correction Factor given Power transmitted by Synchronous Belt, enter Standard Capacity of Belt (Ps) & Power Transmitted by Belt (Pt) and hit the calculate button. Here is how the Service Correction Factor given Power transmitted by Synchronous Belt calculation can be explained with given input values -> 1.299225 = 8380/6450.

FAQ

What is Service Correction Factor given Power transmitted by Synchronous Belt?
The Service Correction Factor given Power transmitted by Synchronous Belt formula is defined as the standard capacity of the belt divided by the power transmitted by the synchronous belt and is represented as Cs = Ps/Pt or Service Correction Factor = Standard Capacity of Belt/Power Transmitted by Belt. Standard Capacity of Belt is the power capacity of the belt from which the power needs to be transmitted to the other end & Power Transmitted by Belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
How to calculate Service Correction Factor given Power transmitted by Synchronous Belt?
The Service Correction Factor given Power transmitted by Synchronous Belt formula is defined as the standard capacity of the belt divided by the power transmitted by the synchronous belt is calculated using Service Correction Factor = Standard Capacity of Belt/Power Transmitted by Belt. To calculate Service Correction Factor given Power transmitted by Synchronous Belt, you need Standard Capacity of Belt (Ps) & Power Transmitted by Belt (Pt). With our tool, you need to enter the respective value for Standard Capacity of Belt & Power Transmitted by Belt and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!