What type of winding is used in a transformer?
In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.
How to Calculate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side?
Secondary Leakage Reactance given Equivalent Reactance from Secondary Side calculator uses Secondary Leakage Reactance = Equivalent Reactance from Secondary-Primary Leakage Reactance*Transformation Ratio^2 to calculate the Secondary Leakage Reactance, The Secondary Leakage Reactance given Equivalent Reactance from Secondary Side formula is defined as the reactance that is in the secondary winding. Secondary Leakage Reactance is denoted by XL2 symbol.
How to calculate Secondary Leakage Reactance given Equivalent Reactance from Secondary Side using this online calculator? To use this online calculator for Secondary Leakage Reactance given Equivalent Reactance from Secondary Side, enter Equivalent Reactance from Secondary (X02), Primary Leakage Reactance (XL1) & Transformation Ratio (K) and hit the calculate button. Here is how the Secondary Leakage Reactance given Equivalent Reactance from Secondary Side calculation can be explained with given input values -> 0.9628 = 2.23-0.88*1.2^2.