Roof Live Load when Tributary Area Les in Range 200 to 600 square feet Solution

STEP 0: Pre-Calculation Summary
Formula Used
Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof
Lf = 20*(1.2-0.001*At)*R2
This formula uses 3 Variables
Variables Used
Roof Live Load - (Measured in Newton) - Roof Live Load is the load to which roof is subjected in addition to its own weight.
Tributary Area - (Measured in Square Meter) - Tributary Area is the area contributing load to the structural member.
Reduction Factor for Slope of Roof - The Reduction Factor for Slope of Roof is the factor by which the slope of the roof reduces.
STEP 1: Convert Input(s) to Base Unit
Tributary Area: 2182.782 Square Foot --> 202.787083458903 Square Meter (Check conversion ​here)
Reduction Factor for Slope of Roof: 0.9 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lf = 20*(1.2-0.001*At)*R2 --> 20*(1.2-0.001*202.787083458903)*0.9
Evaluating ... ...
Lf = 17.9498324977397
STEP 3: Convert Result to Output's Unit
17.9498324977397 Newton --> No Conversion Required
FINAL ANSWER
17.9498324977397 17.94983 Newton <-- Roof Live Load
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Roof Live Loads Calculators

Roof Live Load
​ LaTeX ​ Go Roof Live Load = 20*Reduction Factor for Size of Tributary Area*Reduction Factor for Slope of Roof
Tributary Area given Roof Live Load
​ LaTeX ​ Go Tributary Area = 1000*(1.2-(Roof Live Load/(20*Reduction Factor for Slope of Roof)))
Roof Live Load when Tributary Area Les in Range 200 to 600 square feet
​ LaTeX ​ Go Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet Formula

​LaTeX ​Go
Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof
Lf = 20*(1.2-0.001*At)*R2

What is Live Load?

Live load is the load to which a structure is subjected in addition to its own weight. In other words, it is the extra weight put on a structure apart from the weight of structure itself .

How to Calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?

Roof Live Load when Tributary Area Les in Range 200 to 600 square feet calculator uses Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof to calculate the Roof Live Load, The Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is defined as the live load on roof when the tributary area is more than 200 square feet but less than 600 square feet. Roof Live Load is denoted by Lf symbol.

How to calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet using this online calculator? To use this online calculator for Roof Live Load when Tributary Area Les in Range 200 to 600 square feet, enter Tributary Area (At) & Reduction Factor for Slope of Roof (R2) and hit the calculate button. Here is how the Roof Live Load when Tributary Area Les in Range 200 to 600 square feet calculation can be explained with given input values -> 17.94983 = 20*(1.2-0.001*202.787083458903)*0.9.

FAQ

What is Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?
The Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is defined as the live load on roof when the tributary area is more than 200 square feet but less than 600 square feet and is represented as Lf = 20*(1.2-0.001*At)*R2 or Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof. Tributary Area is the area contributing load to the structural member & The Reduction Factor for Slope of Roof is the factor by which the slope of the roof reduces.
How to calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet?
The Roof Live Load when Tributary Area Les in Range 200 to 600 square feet is defined as the live load on roof when the tributary area is more than 200 square feet but less than 600 square feet is calculated using Roof Live Load = 20*(1.2-0.001*Tributary Area)*Reduction Factor for Slope of Roof. To calculate Roof Live Load when Tributary Area Les in Range 200 to 600 square feet, you need Tributary Area (At) & Reduction Factor for Slope of Roof (R2). With our tool, you need to enter the respective value for Tributary Area & Reduction Factor for Slope of Roof and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Roof Live Load?
In this formula, Roof Live Load uses Tributary Area & Reduction Factor for Slope of Roof. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Roof Live Load = 20*Reduction Factor for Size of Tributary Area*Reduction Factor for Slope of Roof
Let Others Know