RMS Voltage using Load Current (3 Phase 4 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Root Mean Square Voltage = (2*Power Transmitted/3*Current Underground AC*cos(Phase Difference))
Vrms = (2*P/3*I*cos(Φ))
This formula uses 1 Functions, 4 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Root Mean Square Voltage - (Measured in Volt) - Root Mean Square Voltage is the square root of the time average of the voltage squared.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Current Underground AC - (Measured in Ampere) - Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
Current Underground AC: 9 Ampere --> 9 Ampere No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vrms = (2*P/3*I*cos(Φ)) --> (2*300/3*9*cos(0.5235987755982))
Evaluating ... ...
Vrms = 1558.84572681199
STEP 3: Convert Result to Output's Unit
1558.84572681199 Volt --> No Conversion Required
FINAL ANSWER
1558.84572681199 1558.846 Volt <-- Root Mean Square Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Power and Power Factor Calculators

Power Transmitted using Volume of Conductor Material (3 Phase 4 Wire US)
​ LaTeX ​ Go Power Transmitted = sqrt(Line Losses*Volume Of Conductor*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(7*Resistivity*(Length of Underground AC Wire)^2))
Power Transmitted using Load Current (3 Phase 4 Wire US)
​ LaTeX ​ Go Power Transmitted = (3*Maximum Voltage Underground AC*cos(Phase Difference)*Current Underground AC)/sqrt(6)
Angle of PF using Volume of Conductor Material (3 Phase 4 Wire US)
​ LaTeX ​ Go Phase Difference = acos(sqrt((1.75)*Constant Underground AC/Volume Of Conductor))
Power Factor using Volume of Conductor Material (3 Phase 4 Wire US)
​ LaTeX ​ Go Power Factor = sqrt((1.75)*Constant Underground AC/Volume Of Conductor)

RMS Voltage using Load Current (3 Phase 4 Wire US) Formula

​LaTeX ​Go
Root Mean Square Voltage = (2*Power Transmitted/3*Current Underground AC*cos(Phase Difference))
Vrms = (2*P/3*I*cos(Φ))

What is the value of maximum voltage in 3-phase 4-wire Underground system?

The maximum voltage between conductors is vm/√3 so that r.m.s. value of voltage between them is vm/√6.

How to Calculate RMS Voltage using Load Current (3 Phase 4 Wire US)?

RMS Voltage using Load Current (3 Phase 4 Wire US) calculator uses Root Mean Square Voltage = (2*Power Transmitted/3*Current Underground AC*cos(Phase Difference)) to calculate the Root Mean Square Voltage, The RMS Voltage using Load Current (3 phase 4 wire US) formula is defined as the square root of the time average of the voltage squared. Root Mean Square Voltage is denoted by Vrms symbol.

How to calculate RMS Voltage using Load Current (3 Phase 4 Wire US) using this online calculator? To use this online calculator for RMS Voltage using Load Current (3 Phase 4 Wire US), enter Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ) and hit the calculate button. Here is how the RMS Voltage using Load Current (3 Phase 4 Wire US) calculation can be explained with given input values -> 1558.846 = (2*300/3*9*cos(0.5235987755982)).

FAQ

What is RMS Voltage using Load Current (3 Phase 4 Wire US)?
The RMS Voltage using Load Current (3 phase 4 wire US) formula is defined as the square root of the time average of the voltage squared and is represented as Vrms = (2*P/3*I*cos(Φ)) or Root Mean Square Voltage = (2*Power Transmitted/3*Current Underground AC*cos(Phase Difference)). Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work, Current Underground AC is defined as the current flowing through the overhead ac supply wire & Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
How to calculate RMS Voltage using Load Current (3 Phase 4 Wire US)?
The RMS Voltage using Load Current (3 phase 4 wire US) formula is defined as the square root of the time average of the voltage squared is calculated using Root Mean Square Voltage = (2*Power Transmitted/3*Current Underground AC*cos(Phase Difference)). To calculate RMS Voltage using Load Current (3 Phase 4 Wire US), you need Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ). With our tool, you need to enter the respective value for Power Transmitted, Current Underground AC & Phase Difference and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Root Mean Square Voltage?
In this formula, Root Mean Square Voltage uses Power Transmitted, Current Underground AC & Phase Difference. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Root Mean Square Voltage = (2*Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(6*Line Losses*Area of Underground AC Wire))
  • Root Mean Square Voltage = (2*Power Transmitted/cos(Phase Difference))*sqrt(Resistance Underground AC/(6*Line Losses))
  • Root Mean Square Voltage = (Power Transmitted*Length of Underground AC Wire/cos(Phase Difference))*sqrt(Resistivity/(Line Losses*Volume Of Conductor))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!