RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
RMS Output Voltage = 0.84068*Peak Phase Voltage
Vrms = 0.84068*Vm(phase)
This formula uses 2 Variables
Variables Used
RMS Output Voltage - (Measured in Volt) - RMS output voltage is the root mean square value of the average output voltage of the converter.
Peak Phase Voltage - (Measured in Volt) - Peak Phase Voltage is the maximum amplitude of the phase voltage of a 3 phase system.
STEP 1: Convert Input(s) to Base Unit
Peak Phase Voltage: 115.1 Volt --> 115.1 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vrms = 0.84068*Vm(phase) --> 0.84068*115.1
Evaluating ... ...
Vrms = 96.762268
STEP 3: Convert Result to Output's Unit
96.762268 Volt --> No Conversion Required
FINAL ANSWER
96.762268 96.76227 Volt <-- RMS Output Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Rachita C
BMS College Of Engineering (BMSCE), Banglore
Rachita C has verified this Calculator and 50+ more calculators!

Half Wave Calculators

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms
​ LaTeX ​ Go Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage
Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms
​ LaTeX ​ Go Average Output Voltage = (3/(2*pi))*Peak Line Voltage
RMS Output Current of Three Phase Half Wave Diode Rectifier with R Load
​ LaTeX ​ Go Root Mean Square Current = 0.4854*Peak Phase Current
RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load
​ LaTeX ​ Go RMS Output Voltage = 0.84068*Peak Phase Voltage

RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load Formula

​LaTeX ​Go
RMS Output Voltage = 0.84068*Peak Phase Voltage
Vrms = 0.84068*Vm(phase)

Understanding RMS value

The maximum value attained by an alternating quantity during one cycle is called its Peak value. It is also known as the maximum value or amplitude or crest value. The R.M.S value is defined as the square root of means of squares of instantaneous values. When current flows through a resistor of known resistance for a given period of time than as a result the same quantity of heat is produced by the alternating current when flows through the same resistor for the same period of time is called R.M.S or effective value of the alternating current.

How to Calculate RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load?

RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load calculator uses RMS Output Voltage = 0.84068*Peak Phase Voltage to calculate the RMS Output Voltage, The RMS output voltage of three phase half wave diode rectifier with resistive load formula is defined as the RMS value of voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature. RMS Output Voltage is denoted by Vrms symbol.

How to calculate RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load using this online calculator? To use this online calculator for RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load, enter Peak Phase Voltage (Vm(phase)) and hit the calculate button. Here is how the RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load calculation can be explained with given input values -> 96.76227 = 0.84068*115.1.

FAQ

What is RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load?
The RMS output voltage of three phase half wave diode rectifier with resistive load formula is defined as the RMS value of voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature and is represented as Vrms = 0.84068*Vm(phase) or RMS Output Voltage = 0.84068*Peak Phase Voltage. Peak Phase Voltage is the maximum amplitude of the phase voltage of a 3 phase system.
How to calculate RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load?
The RMS output voltage of three phase half wave diode rectifier with resistive load formula is defined as the RMS value of voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature is calculated using RMS Output Voltage = 0.84068*Peak Phase Voltage. To calculate RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load, you need Peak Phase Voltage (Vm(phase)). With our tool, you need to enter the respective value for Peak Phase Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!