Retention Volume given Capacity Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume
VCF = (k'+1)*Vm
This formula uses 3 Variables
Variables Used
Retention Volume given CF - (Measured in Cubic Meter) - Retention Volume given CF is defined as the volume of the mobile phase required to elute the solute from the column.
Capacity Factor - The Capacity factor is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor.
Unretained Mobile Phase Volume - (Measured in Cubic Meter) - The Unretained mobile phase volume is the amount of solute that travels through the column in the minimum possible time.
STEP 1: Convert Input(s) to Base Unit
Capacity Factor: 3 --> No Conversion Required
Unretained Mobile Phase Volume: 4.1 Liter --> 0.0041 Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VCF = (k'+1)*Vm --> (3+1)*0.0041
Evaluating ... ...
VCF = 0.0164
STEP 3: Convert Result to Output's Unit
0.0164 Cubic Meter -->16.4 Liter (Check conversion ​here)
FINAL ANSWER
16.4 Liter <-- Retention Volume given CF
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has created this Calculator and 700+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Retention Volume Calculators

Retention Volume given Flow Rate
​ LaTeX ​ Go Retention Volume given Flow Rate = (Retention Time*Flow Rate of Mobile Phase)
Half of Average Width of Peaks given Resolution and Change in Retention Volume
​ LaTeX ​ Go Half of Average Width of Peak = (0.589*Change in Retention Time)/Resolution
Average Width of Peak given Resolution and Change in Retention Volume
​ LaTeX ​ Go Average Width of Peaks given RV = (Change in retention volume/Resolution)
Flow Rate given Retention Volume and Time
​ LaTeX ​ Go Flow Rate given RT and RV = (Retention Volume/Retention Time)

Retention Volume given Capacity Factor Formula

​LaTeX ​Go
Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume
VCF = (k'+1)*Vm

What is Chromatography?

A separation process based on the various partitioning coefficients of different solutes between the two phases.
Involving the interaction of solute(s) and two phases
Mobile phase: A gas or liquid that moves through the column.
Stationary phase: A solid or liquid that remains in place.

What are the types of Chromatography?

1) Adsorption chromatography
2) Ion-exchange chromatography
3) Partition chromatography
4) Molecular Size exclusion chromatography
5) Affinity chromatography

How to Calculate Retention Volume given Capacity Factor?

Retention Volume given Capacity Factor calculator uses Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume to calculate the Retention Volume given CF, The Retention volume given capacity factor formula is defined as the product of capacity factor in addition to 1 and unretained volume of the solute. Retention Volume given CF is denoted by VCF symbol.

How to calculate Retention Volume given Capacity Factor using this online calculator? To use this online calculator for Retention Volume given Capacity Factor, enter Capacity Factor (k') & Unretained Mobile Phase Volume (Vm) and hit the calculate button. Here is how the Retention Volume given Capacity Factor calculation can be explained with given input values -> 16400 = (3+1)*0.0041.

FAQ

What is Retention Volume given Capacity Factor?
The Retention volume given capacity factor formula is defined as the product of capacity factor in addition to 1 and unretained volume of the solute and is represented as VCF = (k'+1)*Vm or Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume. The Capacity factor is directly proportional to the retention factor. The longer a component is retained by the column, the greater is the capacity factor & The Unretained mobile phase volume is the amount of solute that travels through the column in the minimum possible time.
How to calculate Retention Volume given Capacity Factor?
The Retention volume given capacity factor formula is defined as the product of capacity factor in addition to 1 and unretained volume of the solute is calculated using Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume. To calculate Retention Volume given Capacity Factor, you need Capacity Factor (k') & Unretained Mobile Phase Volume (Vm). With our tool, you need to enter the respective value for Capacity Factor & Unretained Mobile Phase Volume and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!