Resistance using Line Losses (Two-Phase Three-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2)
R = Ploss/((2+sqrt(2))*(I)^2)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Resistance Overhead AC - (Measured in Ohm) - Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Current Overhead AC - (Measured in Ampere) - Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
STEP 1: Convert Input(s) to Base Unit
Line Losses: 8.23 Watt --> 8.23 Watt No Conversion Required
Current Overhead AC: 6.9 Ampere --> 6.9 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R = Ploss/((2+sqrt(2))*(I)^2) --> 8.23/((2+sqrt(2))*(6.9)^2)
Evaluating ... ...
R = 0.0506303547749362
STEP 3: Convert Result to Output's Unit
0.0506303547749362 Ohm --> No Conversion Required
FINAL ANSWER
0.0506303547749362 0.05063 Ohm <-- Resistance Overhead AC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Resistance and Resistivity Calculators

Resistivity using Area of X-Section(Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = (2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/((2+sqrt(2))*Length of Overhead AC Wire*(Power Transmitted^2))
Resistivity using Line Losses (Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = 2*Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted)^2*Length of Overhead AC Wire)
Resistivity using Volume of Conductor Material (Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead AC*(cos(Phase Difference)))^2/(((sqrt(2)+1)*Power Transmitted*Length of Overhead AC Wire)^2)
Resistance(Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire

Resistance using Line Losses (Two-Phase Three-Wire OS) Formula

​LaTeX ​Go
Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2)
R = Ploss/((2+sqrt(2))*(I)^2)

What is the value of maximum voltage and volume of conductor material in 2-phase 3-wire system?

The volume of conductor material required in this system is 1.457/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Resistance using Line Losses (Two-Phase Three-Wire OS)?

Resistance using Line Losses (Two-Phase Three-Wire OS) calculator uses Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2) to calculate the Resistance Overhead AC, The Resistance using Line Losses (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Overhead AC is denoted by R symbol.

How to calculate Resistance using Line Losses (Two-Phase Three-Wire OS) using this online calculator? To use this online calculator for Resistance using Line Losses (Two-Phase Three-Wire OS), enter Line Losses (Ploss) & Current Overhead AC (I) and hit the calculate button. Here is how the Resistance using Line Losses (Two-Phase Three-Wire OS) calculation can be explained with given input values -> 0.05063 = 8.23/((2+sqrt(2))*(6.9)^2).

FAQ

What is Resistance using Line Losses (Two-Phase Three-Wire OS)?
The Resistance using Line Losses (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit and is represented as R = Ploss/((2+sqrt(2))*(I)^2) or Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2). Line Losses is defined as the total losses occurring in an Overhead AC line when in use & Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
How to calculate Resistance using Line Losses (Two-Phase Three-Wire OS)?
The Resistance using Line Losses (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit is calculated using Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2). To calculate Resistance using Line Losses (Two-Phase Three-Wire OS), you need Line Losses (Ploss) & Current Overhead AC (I). With our tool, you need to enter the respective value for Line Losses & Current Overhead AC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistance Overhead AC?
In this formula, Resistance Overhead AC uses Line Losses & Current Overhead AC. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire