Resistance using Line Losses(Two-Wire One Conductor Earthed) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2))
R = Ploss/(2*(I^2))
This formula uses 3 Variables
Variables Used
Resistance Overhead DC - (Measured in Ohm) - Resistance Overhead DC is defined as the property of the wire or line that opposes the flow of current through it.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Current Overhead DC - (Measured in Ampere) - Current Overhead DC is defined as the current flowing through the overhead ac supply wire.
STEP 1: Convert Input(s) to Base Unit
Line Losses: 0.74 Watt --> 0.74 Watt No Conversion Required
Current Overhead DC: 3.1 Ampere --> 3.1 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R = Ploss/(2*(I^2)) --> 0.74/(2*(3.1^2))
Evaluating ... ...
R = 0.0385015608740895
STEP 3: Convert Result to Output's Unit
0.0385015608740895 Ohm --> No Conversion Required
FINAL ANSWER
0.0385015608740895 0.038502 Ohm <-- Resistance Overhead DC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Resistance and Resistivity Calculators

Resistivity using Volume(Two-Wire One Conductor Earthed)
​ LaTeX ​ Go Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/(4*(Power Transmitted^2)*(Length of Wire DC^2))
Resistivity using Line Losses(Two-Wire One Conductor Earthed)
​ LaTeX ​ Go Resistivity = (Line Losses*Area of Overhead DC Wire)/(2*Length of Wire DC*(Current Overhead DC^2))
Resistivity using Resistance(Two-Wire One Conductor Earthed)
​ LaTeX ​ Go Resistivity = Resistance Overhead DC*Area of Overhead DC Wire/Length of Wire DC
Resistance using Line Losses(Two-Wire One Conductor Earthed)
​ LaTeX ​ Go Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2))

Resistance using Line Losses(Two-Wire One Conductor Earthed) Formula

​LaTeX ​Go
Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2))
R = Ploss/(2*(I^2))

What is the two-wire one conductor earthed system?

The load is connected between the two wires. where a1 is the area of the X-section of the conductor. It is a usual practice to make this system the basis for comparison with other systems.

How to Calculate Resistance using Line Losses(Two-Wire One Conductor Earthed)?

Resistance using Line Losses(Two-Wire One Conductor Earthed) calculator uses Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2)) to calculate the Resistance Overhead DC, The Resistance using Line Losses(Two-Wire One Conductor Earthed) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Overhead DC is denoted by R symbol.

How to calculate Resistance using Line Losses(Two-Wire One Conductor Earthed) using this online calculator? To use this online calculator for Resistance using Line Losses(Two-Wire One Conductor Earthed), enter Line Losses (Ploss) & Current Overhead DC (I) and hit the calculate button. Here is how the Resistance using Line Losses(Two-Wire One Conductor Earthed) calculation can be explained with given input values -> 0.038502 = 0.74/(2*(3.1^2)).

FAQ

What is Resistance using Line Losses(Two-Wire One Conductor Earthed)?
The Resistance using Line Losses(Two-Wire One Conductor Earthed) formula is defined as a measure of the opposition to current flow in an electrical circuit and is represented as R = Ploss/(2*(I^2)) or Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2)). Line Losses is defined as the total losses occurring in an Overhead DC line when in use & Current Overhead DC is defined as the current flowing through the overhead ac supply wire.
How to calculate Resistance using Line Losses(Two-Wire One Conductor Earthed)?
The Resistance using Line Losses(Two-Wire One Conductor Earthed) formula is defined as a measure of the opposition to current flow in an electrical circuit is calculated using Resistance Overhead DC = Line Losses/(2*(Current Overhead DC^2)). To calculate Resistance using Line Losses(Two-Wire One Conductor Earthed), you need Line Losses (Ploss) & Current Overhead DC (I). With our tool, you need to enter the respective value for Line Losses & Current Overhead DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!