Reoxygenation Coefficient given Critical Oxygen Deficit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit
KR = KD*Lt*(10^(-KD*tc))/Dc
This formula uses 5 Variables
Variables Used
Reoxygenation Coefficient - (Measured in 1 Per Second) - Reoxygenation Coefficient is referred as the parameter used in water quality modeling to describe the rate at which oxygen is transferred from the atmosphere to the water body.
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is referred as the value obtained after decomposing of oxygen in sewage.
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - The Oxygen Equivalent is referred as the oxidizable organic matter present in sewage.
Critical Time - (Measured in Second) - Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time.
Critical Oxygen Deficit - Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate.
STEP 1: Convert Input(s) to Base Unit
Deoxygenation Constant: 0.23 1 Per Day --> 2.66203703703704E-06 1 Per Second (Check conversion ​here)
Oxygen Equivalent: 0.21 Milligram per Liter --> 0.00021 Kilogram per Cubic Meter (Check conversion ​here)
Critical Time: 0.5 Day --> 43200 Second (Check conversion ​here)
Critical Oxygen Deficit: 0.0003 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KR = KD*Lt*(10^(-KD*tc))/Dc --> 2.66203703703704E-06*0.00021*(10^(-2.66203703703704E-06*43200))/0.0003
Evaluating ... ...
KR = 1.42992129383395E-06
STEP 3: Convert Result to Output's Unit
1.42992129383395E-06 1 Per Second -->0.123545199787253 1 Per Day (Check conversion ​here)
FINAL ANSWER
0.123545199787253 0.123545 1 Per Day <-- Reoxygenation Coefficient
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Reoxygenation Coefficient Calculators

Reoxygenation Coefficient given Critical Oxygen Deficit
​ LaTeX ​ Go Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit
Reoxygenation Coefficient at 20 Degree Celsius
​ LaTeX ​ Go Reoxygenation Coefficient at Temperature 20 = Reoxygenation Coefficient/((1.016)^(Temperature-20))
Reoxygenation Coefficients
​ LaTeX ​ Go Reoxygenation Coefficient = Reoxygenation Coefficient at Temperature 20*(1.016)^(Temperature-20)
Reoxygenation Coefficient given Self Purification Constant
​ LaTeX ​ Go Reoxygenation Coefficient = Deoxygenation Constant*Self-Purification Constant

Reoxygenation Coefficient given Critical Oxygen Deficit Formula

​LaTeX ​Go
Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit
KR = KD*Lt*(10^(-KD*tc))/Dc

What is Critical Oxygen Deficit?

The Critical Oxygen Deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.

How to Calculate Reoxygenation Coefficient given Critical Oxygen Deficit?

Reoxygenation Coefficient given Critical Oxygen Deficit calculator uses Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit to calculate the Reoxygenation Coefficient, The Reoxygenation Coefficient given Critical Oxygen Deficit formula is defined as the rate at which oxygen from the atmosphere is transferred into the water, replenishing the oxygen consumed by biological and chemical processes. This process is essential for maintaining adequate DO levels to support aquatic life. Reoxygenation Coefficient is denoted by KR symbol.

How to calculate Reoxygenation Coefficient given Critical Oxygen Deficit using this online calculator? To use this online calculator for Reoxygenation Coefficient given Critical Oxygen Deficit, enter Deoxygenation Constant (KD), Oxygen Equivalent (Lt), Critical Time (tc) & Critical Oxygen Deficit (Dc) and hit the calculate button. Here is how the Reoxygenation Coefficient given Critical Oxygen Deficit calculation can be explained with given input values -> 10674.31 = 2.66203703703704E-06*0.00021*(10^(-2.66203703703704E-06*43200))/0.0003.

FAQ

What is Reoxygenation Coefficient given Critical Oxygen Deficit?
The Reoxygenation Coefficient given Critical Oxygen Deficit formula is defined as the rate at which oxygen from the atmosphere is transferred into the water, replenishing the oxygen consumed by biological and chemical processes. This process is essential for maintaining adequate DO levels to support aquatic life and is represented as KR = KD*Lt*(10^(-KD*tc))/Dc or Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit. Deoxygenation Constant is referred as the value obtained after decomposing of oxygen in sewage, The Oxygen Equivalent is referred as the oxidizable organic matter present in sewage, Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time & Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate.
How to calculate Reoxygenation Coefficient given Critical Oxygen Deficit?
The Reoxygenation Coefficient given Critical Oxygen Deficit formula is defined as the rate at which oxygen from the atmosphere is transferred into the water, replenishing the oxygen consumed by biological and chemical processes. This process is essential for maintaining adequate DO levels to support aquatic life is calculated using Reoxygenation Coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical Time))/Critical Oxygen Deficit. To calculate Reoxygenation Coefficient given Critical Oxygen Deficit, you need Deoxygenation Constant (KD), Oxygen Equivalent (Lt), Critical Time (tc) & Critical Oxygen Deficit (Dc). With our tool, you need to enter the respective value for Deoxygenation Constant, Oxygen Equivalent, Critical Time & Critical Oxygen Deficit and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Reoxygenation Coefficient?
In this formula, Reoxygenation Coefficient uses Deoxygenation Constant, Oxygen Equivalent, Critical Time & Critical Oxygen Deficit. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Reoxygenation Coefficient = Reoxygenation Coefficient at Temperature 20*(1.016)^(Temperature-20)
  • Reoxygenation Coefficient = Deoxygenation Constant*Self-Purification Constant