Resistivity using Volume of Conductor Material (DC 3-Wire) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2))
ρ = V*Ploss*(Vm^2)/((0.3125)*(P^2)*(L^2))
This formula uses 6 Variables
Variables Used
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Maximum Voltage Overhead DC - (Measured in Volt) - Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the total length of the wire from one end to other end.
STEP 1: Convert Input(s) to Base Unit
Volume of Conductor: 26 Cubic Meter --> 26 Cubic Meter No Conversion Required
Line Losses: 0.74 Watt --> 0.74 Watt No Conversion Required
Maximum Voltage Overhead DC: 60.26 Volt --> 60.26 Volt No Conversion Required
Power Transmitted: 920 Watt --> 920 Watt No Conversion Required
Length of Wire DC: 12.7 Meter --> 12.7 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ρ = V*Ploss*(Vm^2)/((0.3125)*(P^2)*(L^2)) --> 26*0.74*(60.26^2)/((0.3125)*(920^2)*(12.7^2))
Evaluating ... ...
ρ = 0.00163768436976874
STEP 3: Convert Result to Output's Unit
0.00163768436976874 Ohm Meter --> No Conversion Required
FINAL ANSWER
0.00163768436976874 0.001638 Ohm Meter <-- Resistivity
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Resistance and Resistivity Calculators

Resistivity using Volume of Conductor Material (DC 3-Wire)
​ LaTeX ​ Go Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2))
Resistivity using Constant(DC 3-Wire)
​ LaTeX ​ Go Resistivity = Constant Overhead DC*Line Losses*(Maximum Voltage Overhead DC^2)/((Power Transmitted^2)*(Length of Wire DC^2))
Resistivity using Line Losses(DC 3-Wire)
​ LaTeX ​ Go Resistivity = (Line Losses*Area of Overhead DC Wire)/(2*Length of Wire DC*(Current Overhead DC^2))
Resistance using Line Losses(DC 3-Wire)
​ LaTeX ​ Go Resistance Overhead DC = Line Losses/2*(Current Overhead DC^2)

Resistivity using Volume of Conductor Material (DC 3-Wire) Formula

​LaTeX ​Go
Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2))
ρ = V*Ploss*(Vm^2)/((0.3125)*(P^2)*(L^2))

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Resistivity using Volume of Conductor Material (DC 3-Wire)?

Resistivity using Volume of Conductor Material (DC 3-Wire) calculator uses Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2)) to calculate the Resistivity, The Resistivity using Volume of Conductor Material (DC 3-wire) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to calculate Resistivity using Volume of Conductor Material (DC 3-Wire) using this online calculator? To use this online calculator for Resistivity using Volume of Conductor Material (DC 3-Wire), enter Volume of Conductor (V), Line Losses (Ploss), Maximum Voltage Overhead DC (Vm), Power Transmitted (P) & Length of Wire DC (L) and hit the calculate button. Here is how the Resistivity using Volume of Conductor Material (DC 3-Wire) calculation can be explained with given input values -> 0.001638 = 26*0.74*(60.26^2)/((0.3125)*(920^2)*(12.7^2)).

FAQ

What is Resistivity using Volume of Conductor Material (DC 3-Wire)?
The Resistivity using Volume of Conductor Material (DC 3-wire) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors and is represented as ρ = V*Ploss*(Vm^2)/((0.3125)*(P^2)*(L^2)) or Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2)). Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line, Line Losses is defined as the total losses occurring in an Overhead DC line when in use, Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire, Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end & Length of Wire DC is the total length of the wire from one end to other end.
How to calculate Resistivity using Volume of Conductor Material (DC 3-Wire)?
The Resistivity using Volume of Conductor Material (DC 3-wire) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors is calculated using Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/((0.3125)*(Power Transmitted^2)*(Length of Wire DC^2)). To calculate Resistivity using Volume of Conductor Material (DC 3-Wire), you need Volume of Conductor (V), Line Losses (Ploss), Maximum Voltage Overhead DC (Vm), Power Transmitted (P) & Length of Wire DC (L). With our tool, you need to enter the respective value for Volume of Conductor, Line Losses, Maximum Voltage Overhead DC, Power Transmitted & Length of Wire DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistivity?
In this formula, Resistivity uses Volume of Conductor, Line Losses, Maximum Voltage Overhead DC, Power Transmitted & Length of Wire DC. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Resistivity = (Line Losses*Area of Overhead DC Wire)/(2*Length of Wire DC*(Current Overhead DC^2))
  • Resistivity = Constant Overhead DC*Line Losses*(Maximum Voltage Overhead DC^2)/((Power Transmitted^2)*(Length of Wire DC^2))
  • Resistivity = (Line Losses*Area of Overhead DC Wire)/(2*Length of Wire DC*(Current Overhead DC^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!