Resistivity using Area of X-Section(2-Phase 4-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2))
ρ = 2*A*(Vm^2)*Ploss*((cos(Φ))^2)/(L*(P^2))
This formula uses 1 Functions, 7 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Area of Overhead AC Wire - (Measured in Square Meter) - Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Maximum Voltage Overhead AC - (Measured in Volt) - Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Length of Overhead AC Wire - (Measured in Meter) - Length of Overhead AC Wire is the total length of the wire from one end to other end.
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
STEP 1: Convert Input(s) to Base Unit
Area of Overhead AC Wire: 0.79 Square Meter --> 0.79 Square Meter No Conversion Required
Maximum Voltage Overhead AC: 62 Volt --> 62 Volt No Conversion Required
Line Losses: 8.23 Watt --> 8.23 Watt No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
Length of Overhead AC Wire: 10.63 Meter --> 10.63 Meter No Conversion Required
Power Transmitted: 890 Watt --> 890 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ρ = 2*A*(Vm^2)*Ploss*((cos(Φ))^2)/(L*(P^2)) --> 2*0.79*(62^2)*8.23*((cos(0.5235987755982))^2)/(10.63*(890^2))
Evaluating ... ...
ρ = 0.00445233964325276
STEP 3: Convert Result to Output's Unit
0.00445233964325276 Ohm Meter --> No Conversion Required
FINAL ANSWER
0.00445233964325276 0.004452 Ohm Meter <-- Resistivity
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Resistance and Resistivity Calculators

Resistivity using Area of X-Section(2-Phase 4-Wire OS)
​ LaTeX ​ Go Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2))
Resistance using Line Losses (2-Phase 4-Wire OS)
​ LaTeX ​ Go Resistance Overhead AC = 2*Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/((Power Transmitted)^2)
Resistance(2-Phase 4-Wire OS)
​ LaTeX ​ Go Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire
Resistance using Load Current (2-Phase 4-Wire OS)
​ LaTeX ​ Go Resistance Overhead AC = Line Losses/(4*(Current Overhead AC)^2)

Resistivity using Area of X-Section(2-Phase 4-Wire OS) Formula

​LaTeX ​Go
Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2))
ρ = 2*A*(Vm^2)*Ploss*((cos(Φ))^2)/(L*(P^2))

What is the value of maximum voltage and volume of conductor material in 2-phase 4-wire system?

The volume of conductor material required in this system is 1/2cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Resistivity using Area of X-Section(2-Phase 4-Wire OS)?

Resistivity using Area of X-Section(2-Phase 4-Wire OS) calculator uses Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2)) to calculate the Resistivity, The Resistivity using Area of X-Section(2-phase 4-wire OS) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors. Resistivity is denoted by ρ symbol.

How to calculate Resistivity using Area of X-Section(2-Phase 4-Wire OS) using this online calculator? To use this online calculator for Resistivity using Area of X-Section(2-Phase 4-Wire OS), enter Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm), Line Losses (Ploss), Phase Difference (Φ), Length of Overhead AC Wire (L) & Power Transmitted (P) and hit the calculate button. Here is how the Resistivity using Area of X-Section(2-Phase 4-Wire OS) calculation can be explained with given input values -> 0.004452 = 2*0.79*(62^2)*8.23*((cos(0.5235987755982))^2)/(10.63*(890^2)).

FAQ

What is Resistivity using Area of X-Section(2-Phase 4-Wire OS)?
The Resistivity using Area of X-Section(2-phase 4-wire OS) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors and is represented as ρ = 2*A*(Vm^2)*Ploss*((cos(Φ))^2)/(L*(P^2)) or Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2)). Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system, Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire, Line Losses is defined as the total losses occurring in an Overhead AC line when in use, Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit, Length of Overhead AC Wire is the total length of the wire from one end to other end & Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
How to calculate Resistivity using Area of X-Section(2-Phase 4-Wire OS)?
The Resistivity using Area of X-Section(2-phase 4-wire OS) formula is defined as a characteristic property of each material, resistivity is useful in comparing various materials on the basis of their ability to conduct electric currents. High resistivity designates poor conductors is calculated using Resistivity = 2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(Length of Overhead AC Wire*(Power Transmitted^2)). To calculate Resistivity using Area of X-Section(2-Phase 4-Wire OS), you need Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm), Line Losses (Ploss), Phase Difference (Φ), Length of Overhead AC Wire (L) & Power Transmitted (P). With our tool, you need to enter the respective value for Area of Overhead AC Wire, Maximum Voltage Overhead AC, Line Losses, Phase Difference, Length of Overhead AC Wire & Power Transmitted and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistivity?
In this formula, Resistivity uses Area of Overhead AC Wire, Maximum Voltage Overhead AC, Line Losses, Phase Difference, Length of Overhead AC Wire & Power Transmitted. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Resistivity = 2*Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/((Power Transmitted)^2*Length of Overhead AC Wire)
  • Resistivity = Line Losses*Area of Overhead AC Wire/(Length of Overhead AC Wire*(2*Current Overhead AC)^2)