STEP 0: Pre-Calculation Summary
Formula Used
Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire
R = ρ*L/A
This formula uses 4 Variables
Variables Used
Resistance Overhead AC - (Measured in Ohm) - Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Overhead AC Wire - (Measured in Meter) - Length of Overhead AC Wire is the total length of the wire from one end to other end.
Area of Overhead AC Wire - (Measured in Square Meter) - Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
STEP 1: Convert Input(s) to Base Unit
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Overhead AC Wire: 10.63 Meter --> 10.63 Meter No Conversion Required
Area of Overhead AC Wire: 0.79 Square Meter --> 0.79 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R = ρ*L/A --> 1.7E-05*10.63/0.79
Evaluating ... ...
R = 0.000228746835443038
STEP 3: Convert Result to Output's Unit
0.000228746835443038 Ohm --> No Conversion Required
FINAL ANSWER
0.000228746835443038 0.000229 Ohm <-- Resistance Overhead AC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Resistance and Resistivity Calculators

Resistivity using Area of X-Section(Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = (2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/((2+sqrt(2))*Length of Overhead AC Wire*(Power Transmitted^2))
Resistivity using Line Losses (Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = 2*Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted)^2*Length of Overhead AC Wire)
Resistivity using Volume of Conductor Material (Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead AC*(cos(Phase Difference)))^2/(((sqrt(2)+1)*Power Transmitted*Length of Overhead AC Wire)^2)
Resistance(Two-Phase Three-Wire OS)
​ LaTeX ​ Go Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire

Resistance(Two-Phase Three-Wire OS) Formula

​LaTeX ​Go
Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire
R = ρ*L/A

What is the value of maximum voltage and volume of conductor material in 2-phase 3-wire system?

The volume of conductor material required in this system is 5/8cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Resistance(Two-Phase Three-Wire OS)?

Resistance(Two-Phase Three-Wire OS) calculator uses Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire to calculate the Resistance Overhead AC, The Resistance(two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance Overhead AC is denoted by R symbol.

How to calculate Resistance(Two-Phase Three-Wire OS) using this online calculator? To use this online calculator for Resistance(Two-Phase Three-Wire OS), enter Resistivity (ρ), Length of Overhead AC Wire (L) & Area of Overhead AC Wire (A) and hit the calculate button. Here is how the Resistance(Two-Phase Three-Wire OS) calculation can be explained with given input values -> 0.000229 = 1.7E-05*10.63/0.79.

FAQ

What is Resistance(Two-Phase Three-Wire OS)?
The Resistance(two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit and is represented as R = ρ*L/A or Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire. Resistivity is the measure of how strongly a material opposes the flow of current through them, Length of Overhead AC Wire is the total length of the wire from one end to other end & Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
How to calculate Resistance(Two-Phase Three-Wire OS)?
The Resistance(two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit is calculated using Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire. To calculate Resistance(Two-Phase Three-Wire OS), you need Resistivity (ρ), Length of Overhead AC Wire (L) & Area of Overhead AC Wire (A). With our tool, you need to enter the respective value for Resistivity, Length of Overhead AC Wire & Area of Overhead AC Wire and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistance Overhead AC?
In this formula, Resistance Overhead AC uses Resistivity, Length of Overhead AC Wire & Area of Overhead AC Wire. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2)