Reserve Storage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire
VR = (F-P)*t
This formula uses 4 Variables
Variables Used
Reserve Storage - (Measured in Cubic Meter) - Reserve Storage refers to the capacity within a system, such as a reservoir or a water treatment facility, that is intentionally left unused or untapped under normal operating conditions.
Fire Demand - (Measured in Cubic Meter per Second) - Fire Demand is the amount of water required to extinguish fire.
Capacity of Pump - (Measured in Cubic Meter per Second) - Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time.
Duration of Fire - (Measured in Second) - Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem.
STEP 1: Convert Input(s) to Base Unit
Fire Demand: 1100 Liter per day --> 1.27314814814815E-05 Cubic Meter per Second (Check conversion ​here)
Capacity of Pump: 120 Liter per day --> 1.38888888888889E-06 Cubic Meter per Second (Check conversion ​here)
Duration of Fire: 2 Day --> 172800 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VR = (F-P)*t --> (1.27314814814815E-05-1.38888888888889E-06)*172800
Evaluating ... ...
VR = 1.96
STEP 3: Convert Result to Output's Unit
1.96 Cubic Meter -->1960 Liter (Check conversion ​here)
FINAL ANSWER
1960 Liter <-- Reserve Storage
(Calculation completed in 00.021 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Capacity of Distribution Reservoir Calculators

Reserve Fire Pumping Capacity given Reserve Storage
​ LaTeX ​ Go Capacity of Pump = Fire Demand-(Reserve Storage/Duration of Fire)
Fire Duration given Reserve Storage
​ LaTeX ​ Go Duration of Fire = Reserve Storage/(Fire Demand-Capacity of Pump)
Fire Demand given Reserve Storage
​ LaTeX ​ Go Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump
Reserve Storage
​ LaTeX ​ Go Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire

Reserve Storage Formula

​LaTeX ​Go
Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire
VR = (F-P)*t

What is the Storage Capacity of Reservoirs?

The Storage Capacity represents the total capacity of the reservoir, while the Initial Storage is the amount of water initially stored there at the beginning of the first month of the Current Accounts year.

How to Calculate Reserve Storage?

Reserve Storage calculator uses Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire to calculate the Reserve Storage, The Reserve Storage is defined as the the capacity within a system, such as a water treatment facility or a reservoir, when we have prior information of other parameters used. Reserve Storage is denoted by VR symbol.

How to calculate Reserve Storage using this online calculator? To use this online calculator for Reserve Storage, enter Fire Demand (F), Capacity of Pump (P) & Duration of Fire (t) and hit the calculate button. Here is how the Reserve Storage calculation can be explained with given input values -> 2E+6 = (1.27314814814815E-05-1.38888888888889E-06)*172800.

FAQ

What is Reserve Storage?
The Reserve Storage is defined as the the capacity within a system, such as a water treatment facility or a reservoir, when we have prior information of other parameters used and is represented as VR = (F-P)*t or Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire. Fire Demand is the amount of water required to extinguish fire, Capacity of Pump refers to the volume of fluid (such as water, sewage, or other liquids) that the pump is capable of moving within a given amount of time & Duration of Fire refers to the length of time that a fire burns within a given area or ecosystem.
How to calculate Reserve Storage?
The Reserve Storage is defined as the the capacity within a system, such as a water treatment facility or a reservoir, when we have prior information of other parameters used is calculated using Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire. To calculate Reserve Storage, you need Fire Demand (F), Capacity of Pump (P) & Duration of Fire (t). With our tool, you need to enter the respective value for Fire Demand, Capacity of Pump & Duration of Fire and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!