Reflected Current for Refracted Wave Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reflected Current = (-1)*Reflected Voltage/Characteristic Impedance
Ir = (-1)*Er/Z0
This formula uses 3 Variables
Variables Used
Reflected Current - (Measured in Ampere) - Reflected Current is defined as the current wave that is traveling from the receiving end to the sending end of the Transmission line during transient condition.
Reflected Voltage - (Measured in Volt) - Reflected Voltage is the voltage that is reflected in the transmission line during transient condition.
Characteristic Impedance - (Measured in Ohm) - The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
STEP 1: Convert Input(s) to Base Unit
Reflected Voltage: 4.5 Volt --> 4.5 Volt No Conversion Required
Characteristic Impedance: 55.5 Ohm --> 55.5 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ir = (-1)*Er/Z0 --> (-1)*4.5/55.5
Evaluating ... ...
Ir = -0.0810810810810811
STEP 3: Convert Result to Output's Unit
-0.0810810810810811 Ampere --> No Conversion Required
FINAL ANSWER
-0.0810810810810811 -0.081081 Ampere <-- Reflected Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Transient Calculators

Load Impedance using Reflected Coefficient of Current
​ LaTeX ​ Go Load Impedance = Characteristic Impedance*(1-Reflection Coefficient of Current)/(Reflection Coefficient of Current-1)
Load Impedance using Reflected Coefficient of Voltage
​ LaTeX ​ Go Load Impedance = Characteristic Impedance*(Reflection Coefficient of Voltage+1)/(1-Reflection Coefficient of Voltage)
Characteristic Impedance (Line SC)
​ LaTeX ​ Go Characteristic Impedance = Incident Voltage/Incident Current
Incident Voltage using Transmitted Voltage (Load OC)
​ LaTeX ​ Go Incident Voltage = Transmitted Voltage/2

Reflected Current for Refracted Wave Formula

​LaTeX ​Go
Reflected Current = (-1)*Reflected Voltage/Characteristic Impedance
Ir = (-1)*Er/Z0

Define characteristic impedance.

The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line.

How to Calculate Reflected Current for Refracted Wave?

Reflected Current for Refracted Wave calculator uses Reflected Current = (-1)*Reflected Voltage/Characteristic Impedance to calculate the Reflected Current, The Reflected Current for Refracted Wave formula is defined as the current wave that is traveling from the receiving end to the sending end of the Transmission line. Reflected Current is denoted by Ir symbol.

How to calculate Reflected Current for Refracted Wave using this online calculator? To use this online calculator for Reflected Current for Refracted Wave, enter Reflected Voltage (Er) & Characteristic Impedance (Z0) and hit the calculate button. Here is how the Reflected Current for Refracted Wave calculation can be explained with given input values -> -0.081081 = (-1)*4.5/55.5.

FAQ

What is Reflected Current for Refracted Wave?
The Reflected Current for Refracted Wave formula is defined as the current wave that is traveling from the receiving end to the sending end of the Transmission line and is represented as Ir = (-1)*Er/Z0 or Reflected Current = (-1)*Reflected Voltage/Characteristic Impedance. Reflected Voltage is the voltage that is reflected in the transmission line during transient condition & The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
How to calculate Reflected Current for Refracted Wave?
The Reflected Current for Refracted Wave formula is defined as the current wave that is traveling from the receiving end to the sending end of the Transmission line is calculated using Reflected Current = (-1)*Reflected Voltage/Characteristic Impedance. To calculate Reflected Current for Refracted Wave, you need Reflected Voltage (Er) & Characteristic Impedance (Z0). With our tool, you need to enter the respective value for Reflected Voltage & Characteristic Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Reflected Current?
In this formula, Reflected Current uses Reflected Voltage & Characteristic Impedance. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Reflected Current = Reflection Coefficient of Current*Incident Current
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!