Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Rai = 25*Acr*Pnm
This formula uses 3 Variables
Variables Used
Recharge from Rainfall in Alluvial Indo - (Measured in Cubic Meter per Second) - The Recharge from Rainfall in Alluvial Indo refers to the process by which rainwater infiltrates through the soil and percolates down to replenish groundwater aquifers in alluvial plains.
Area of Computation for Recharge - (Measured in Square Meter) - The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Normal Rainfall in Monsoon Season - (Measured in Meter) - The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
STEP 1: Convert Input(s) to Base Unit
Area of Computation for Recharge: 13.3 Square Meter --> 13.3 Square Meter No Conversion Required
Normal Rainfall in Monsoon Season: 0.024 Meter --> 0.024 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rai = 25*Acr*Pnm --> 25*13.3*0.024
Evaluating ... ...
Rai = 7.98
STEP 3: Convert Result to Output's Unit
7.98 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
7.98 Cubic Meter per Second <-- Recharge from Rainfall in Alluvial Indo
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

Maximum value of Rainfall Factor for Various Hydrogeologic Conditions based on the Norms Calculators

Recharge from Rainfall in Alluvial East Coast Areas for Known Maximum Rainfall Factor
​ LaTeX ​ Go Recharge from Rainfall in Alluvial East Coast = 18*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Recharge from Rainfall in Alluvial West Coast Areas for Known Maximum Rainfall Factor
​ LaTeX ​ Go Recharge from Rainfall in Alluvial West Coast = 12*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Recharge from Rainfall in Hard Rock Areas with Low Clay Content for Known Rainfall Factor
​ LaTeX ​ Go Recharge from Rainfall in Hard Rock Low Clay = 12*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor
​ LaTeX ​ Go Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season

Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor Formula

​LaTeX ​Go
Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Rai = 25*Acr*Pnm

What is Catchment Area?

A Catchment is an area of land where water collects when it rains, often bounded by hills. As the water flows over the landscape it finds its way into streams and down into the soil, eventually feeding the river.

How to Calculate Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor?

Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor calculator uses Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season to calculate the Recharge from Rainfall in Alluvial Indo, The Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor formula is defined as the process by which water from precipitation percolates through the soil and rock layers to replenish groundwater aquifers. In the context of the alluvial Indo-Gangetic plains and inland areas, this recharge is influenced by the region's high permeability soils and extensive aquifer systems. Recharge from Rainfall in Alluvial Indo is denoted by Rai symbol.

How to calculate Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor using this online calculator? To use this online calculator for Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor, enter Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button. Here is how the Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor calculation can be explained with given input values -> 7.98 = 25*13.3*0.024.

FAQ

What is Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor?
The Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor formula is defined as the process by which water from precipitation percolates through the soil and rock layers to replenish groundwater aquifers. In the context of the alluvial Indo-Gangetic plains and inland areas, this recharge is influenced by the region's high permeability soils and extensive aquifer systems and is represented as Rai = 25*Acr*Pnm or Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources & The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
How to calculate Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor?
The Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor formula is defined as the process by which water from precipitation percolates through the soil and rock layers to replenish groundwater aquifers. In the context of the alluvial Indo-Gangetic plains and inland areas, this recharge is influenced by the region's high permeability soils and extensive aquifer systems is calculated using Recharge from Rainfall in Alluvial Indo = 25*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. To calculate Recharge from Rainfall in Alluvial Indo Gangetic and Inland Areas for Known Max Rainfall Factor, you need Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm). With our tool, you need to enter the respective value for Area of Computation for Recharge & Normal Rainfall in Monsoon Season and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!