Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method Solution

STEP 0: Pre-Calculation Summary
Formula Used
Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Rrfm = f*Acr*Pnm
This formula uses 4 Variables
Variables Used
Recharge from Rainfall in Monsoon Season - (Measured in Cubic Meter per Second) - Recharge from Rainfall in Monsoon Season is the infiltration and percolation of rainwater into subsurface aquifers, primarily occurring during the monsoon period when rainfall is significantly higher.
Rainfall Infiltration Factor - The Rainfall Infiltration Factor refers to the measure of the rate at which water from rainfall penetrates into the soil, a critical parameter, influencing design and management of water resources.
Area of Computation for Recharge - (Measured in Square Meter) - The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Normal Rainfall in Monsoon Season - (Measured in Meter) - The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
STEP 1: Convert Input(s) to Base Unit
Rainfall Infiltration Factor: 22 --> No Conversion Required
Area of Computation for Recharge: 13.3 Square Meter --> 13.3 Square Meter No Conversion Required
Normal Rainfall in Monsoon Season: 0.024 Meter --> 0.024 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rrfm = f*Acr*Pnm --> 22*13.3*0.024
Evaluating ... ...
Rrfm = 7.0224
STEP 3: Convert Result to Output's Unit
7.0224 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
7.0224 Cubic Meter per Second <-- Recharge from Rainfall in Monsoon Season
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Rainfall Infiltration Method Calculators

Rainfall Infiltration Factor when Recharge from Rainfall is Considered
​ LaTeX ​ Go Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season)
Catchment Area when Recharge from Rainfall is Considered
​ LaTeX ​ Go Area of Computation for Recharge = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Normal Rainfall in Monsoon Season)
Normal Rainfall in Monsoon Season
​ LaTeX ​ Go Normal Rainfall in Monsoon Season = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Area of Computation for Recharge)
Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method
​ LaTeX ​ Go Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season

Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method Formula

​LaTeX ​Go
Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season
Rrfm = f*Acr*Pnm

What is Groundwater Flow?

Groundwater flow is defined as the "part of streamflow that has infiltrated the ground, entered the phreatic zone, and has been discharged into a stream channel or springs; and seepage water." It is governed by the groundwater flow equation.

How to Calculate Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method?

Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method calculator uses Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season to calculate the Recharge from Rainfall in Monsoon Season, The Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method formula is defined as a hydrologic process, where water moves downward from surface water to groundwater. Recharge is the primary method through which water enters an aquifer in the Monsoon Season. Recharge from Rainfall in Monsoon Season is denoted by Rrfm symbol.

How to calculate Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method using this online calculator? To use this online calculator for Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method, enter Rainfall Infiltration Factor (f), Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button. Here is how the Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method calculation can be explained with given input values -> 7.0224 = 22*13.3*0.024.

FAQ

What is Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method?
The Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method formula is defined as a hydrologic process, where water moves downward from surface water to groundwater. Recharge is the primary method through which water enters an aquifer in the Monsoon Season and is represented as Rrfm = f*Acr*Pnm or Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. The Rainfall Infiltration Factor refers to the measure of the rate at which water from rainfall penetrates into the soil, a critical parameter, influencing design and management of water resources, The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources & The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
How to calculate Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method?
The Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method formula is defined as a hydrologic process, where water moves downward from surface water to groundwater. Recharge is the primary method through which water enters an aquifer in the Monsoon Season is calculated using Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season. To calculate Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method, you need Rainfall Infiltration Factor (f), Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm). With our tool, you need to enter the respective value for Rainfall Infiltration Factor, Area of Computation for Recharge & Normal Rainfall in Monsoon Season and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!