Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor
XA Batch = (kBatch*𝛕Batch)/Co Batch
This formula uses 4 Variables
Variables Used
Reactant Conversion in Batch - Reactant Conversion in Batch gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Rate Constant for Zero Order in Batch - (Measured in Mole per Cubic Meter Second) - The Rate Constant for Zero Order in Batch is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant.
Space Time in Batch Reactor - (Measured in Second) - Space Time in Batch Reactor is the time necessary to process volume of reactor fluid at the entrance conditions.
Initial Reactant Concentration in Batch Reactor - (Measured in Mole per Cubic Meter) - The Initial Reactant Concentration in Batch Reactor refers to the amount of reactant present in the solvent before the considered process.
STEP 1: Convert Input(s) to Base Unit
Rate Constant for Zero Order in Batch: 1121 Mole per Cubic Meter Second --> 1121 Mole per Cubic Meter Second No Conversion Required
Space Time in Batch Reactor: 0.051 Second --> 0.051 Second No Conversion Required
Initial Reactant Concentration in Batch Reactor: 81.5 Mole per Cubic Meter --> 81.5 Mole per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
XA Batch = (kBatch*𝛕Batch)/Co Batch --> (1121*0.051)/81.5
Evaluating ... ...
XA Batch = 0.701484662576687
STEP 3: Convert Result to Output's Unit
0.701484662576687 --> No Conversion Required
FINAL ANSWER
0.701484662576687 0.701485 <-- Reactant Conversion in Batch
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by akhilesh
K. K. Wagh Institute of Engineering Education and Research (K.K.W.I.E.E.R.), Nashik
akhilesh has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Plug Flow or Batch Calculators

Initial Reactant Concentration for Zero Order Reaction using Space Time for Plug Flow
​ LaTeX ​ Go Initial Reactant Concentration in Batch Reactor = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Reactant Conversion in Batch
Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow
​ LaTeX ​ Go Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor
Rate Constant for Zero Order Reaction using Space Time for Plug Flow
​ LaTeX ​ Go Rate Constant for Zero Order in Batch = (Reactant Conversion in Batch*Initial Reactant Concentration in Batch Reactor)/Space Time in Batch Reactor
Space Time for Zero Order Reaction for Plug Flow
​ LaTeX ​ Go Space Time in Batch Reactor = (Reactant Conversion in Batch*Initial Reactant Concentration in Batch Reactor)/Rate Constant for Zero Order in Batch

Reactor Performance Equations for Constant Volume Reactions Calculators

Initial Reactant Concentration for Second Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Space Time in Mixed Flow)*(Rate Constant for Second Order in Mixed Flow))
Rate Constant for First Order Reaction using Reactant Concentration for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*((Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/Reactant Concentration at given Time)
Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Rate Constant for First Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow))

Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow Formula

​LaTeX ​Go
Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor
XA Batch = (kBatch*𝛕Batch)/Co Batch

What is Plug Flow Reactor?

The plug flow reactor model (PFR, sometimes called continuous tubular reactor, CTR, or piston flow reactors) is a model used to describe chemical reactions in continuous, flowing systems of cylindrical geometry. The PFR model is used to predict the behavior of chemical reactors of such design, so that key reactor variables, such as the dimensions of the reactor, can be estimated.

How to Calculate Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow?

Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow calculator uses Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor to calculate the Reactant Conversion in Batch, The Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow formula is defined as the amount of reactant converted into product for zero order reaction where fractional volume change is zero. Reactant Conversion in Batch is denoted by XA Batch symbol.

How to calculate Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow using this online calculator? To use this online calculator for Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow, enter Rate Constant for Zero Order in Batch (kBatch), Space Time in Batch Reactor (𝛕Batch) & Initial Reactant Concentration in Batch Reactor (Co Batch) and hit the calculate button. Here is how the Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow calculation can be explained with given input values -> 0.701485 = (1121*0.051)/81.5.

FAQ

What is Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow?
The Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow formula is defined as the amount of reactant converted into product for zero order reaction where fractional volume change is zero and is represented as XA Batch = (kBatch*𝛕Batch)/Co Batch or Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor. The Rate Constant for Zero Order in Batch is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant, Space Time in Batch Reactor is the time necessary to process volume of reactor fluid at the entrance conditions & The Initial Reactant Concentration in Batch Reactor refers to the amount of reactant present in the solvent before the considered process.
How to calculate Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow?
The Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow formula is defined as the amount of reactant converted into product for zero order reaction where fractional volume change is zero is calculated using Reactant Conversion in Batch = (Rate Constant for Zero Order in Batch*Space Time in Batch Reactor)/Initial Reactant Concentration in Batch Reactor. To calculate Reactant Conversion for Zero Order Reaction using Space Time for Plug Flow, you need Rate Constant for Zero Order in Batch (kBatch), Space Time in Batch Reactor (𝛕Batch) & Initial Reactant Concentration in Batch Reactor (Co Batch). With our tool, you need to enter the respective value for Rate Constant for Zero Order in Batch, Space Time in Batch Reactor & Initial Reactant Concentration in Batch Reactor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!