Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)
C = Co-(kmixed flow*𝛕mixed)
This formula uses 4 Variables
Variables Used
Reactant Concentration at given Time - (Measured in Mole per Cubic Meter) - The Reactant Concentration at given Time refers to the amount of reactant present in the solvent at any given point of time during the process.
Initial Reactant Concentration in Mixed Flow - (Measured in Mole per Cubic Meter) - The Initial Reactant Concentration in Mixed Flow refers to the amount of reactant present in the solvent before the considered process.
Rate Constant for Zero Order in Mixed Flow - (Measured in Mole per Cubic Meter Second) - The Rate Constant for Zero Order in Mixed Flow is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant.
Space Time in Mixed Flow - (Measured in Second) - Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions.
STEP 1: Convert Input(s) to Base Unit
Initial Reactant Concentration in Mixed Flow: 80 Mole per Cubic Meter --> 80 Mole per Cubic Meter No Conversion Required
Rate Constant for Zero Order in Mixed Flow: 1125 Mole per Cubic Meter Second --> 1125 Mole per Cubic Meter Second No Conversion Required
Space Time in Mixed Flow: 0.05 Second --> 0.05 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
C = Co-(kmixed flow*𝛕mixed) --> 80-(1125*0.05)
Evaluating ... ...
C = 23.75
STEP 3: Convert Result to Output's Unit
23.75 Mole per Cubic Meter --> No Conversion Required
FINAL ANSWER
23.75 Mole per Cubic Meter <-- Reactant Concentration at given Time
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by akhilesh
K. K. Wagh Institute of Engineering Education and Research (K.K.W.I.E.E.R.), Nashik
akhilesh has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Mixed Flow Calculators

Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)
Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Reactant Conversion for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Reactant Conversion in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Initial Reactant Concentration in Mixed Flow
Rate Constant for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Rate Constant for Zero Order in Mixed Flow = (Reactant Conversion in Mixed Flow*Initial Reactant Concentration in Mixed Flow)/Space Time in Mixed Flow

Reactor Performance Equations for Constant Volume Reactions Calculators

Initial Reactant Concentration for Second Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Space Time in Mixed Flow)*(Rate Constant for Second Order in Mixed Flow))
Rate Constant for First Order Reaction using Reactant Concentration for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*((Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/Reactant Concentration at given Time)
Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Rate Constant for First Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow))

Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow Formula

​LaTeX ​Go
Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)
C = Co-(kmixed flow*𝛕mixed)

What is continuous stirred-tank reactor?

The continuous stirred-tank reactor (CSTR), also known as vat- or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using a continuous agitated-tank reactor to reach a specified output. The mathematical model works for all fluids: liquids, gases, and slurries.

How to Calculate Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?

Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow calculator uses Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow) to calculate the Reactant Concentration at given Time, The Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant at any give time for zero order reaction for mixed flow where there is zero fractional volume change. Reactant Concentration at given Time is denoted by C symbol.

How to calculate Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow using this online calculator? To use this online calculator for Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow, enter Initial Reactant Concentration in Mixed Flow (Co), Rate Constant for Zero Order in Mixed Flow (kmixed flow) & Space Time in Mixed Flow (𝛕mixed) and hit the calculate button. Here is how the Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow calculation can be explained with given input values -> 24 = 80-(1125*0.05).

FAQ

What is Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?
The Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant at any give time for zero order reaction for mixed flow where there is zero fractional volume change and is represented as C = Co-(kmixed flow*𝛕mixed) or Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow). The Initial Reactant Concentration in Mixed Flow refers to the amount of reactant present in the solvent before the considered process, The Rate Constant for Zero Order in Mixed Flow is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant & Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions.
How to calculate Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?
The Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant at any give time for zero order reaction for mixed flow where there is zero fractional volume change is calculated using Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow). To calculate Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow, you need Initial Reactant Concentration in Mixed Flow (Co), Rate Constant for Zero Order in Mixed Flow (kmixed flow) & Space Time in Mixed Flow (𝛕mixed). With our tool, you need to enter the respective value for Initial Reactant Concentration in Mixed Flow, Rate Constant for Zero Order in Mixed Flow & Space Time in Mixed Flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!