Reactance of Primary Winding in Secondary Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2
X'1 = XL1*K^2
This formula uses 3 Variables
Variables Used
Reactance of Primary in Secondary - (Measured in Ohm) - Reactance of Primary in Secondary referred to as secondary is the Reactance of Primary winding in Secondary.
Primary Leakage Reactance - (Measured in Ohm) - Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
Transformation Ratio - The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
STEP 1: Convert Input(s) to Base Unit
Primary Leakage Reactance: 0.88 Ohm --> 0.88 Ohm No Conversion Required
Transformation Ratio: 1.2 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
X'1 = XL1*K^2 --> 0.88*1.2^2
Evaluating ... ...
X'1 = 1.2672
STEP 3: Convert Result to Output's Unit
1.2672 Ohm --> No Conversion Required
FINAL ANSWER
1.2672 Ohm <-- Reactance of Primary in Secondary
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Reactance Calculators

Secondary Leakage Reactance given Equivalent Reactance from Secondary Side
​ LaTeX ​ Go Secondary Leakage Reactance = Equivalent Reactance from Secondary-Primary Leakage Reactance*Transformation Ratio^2
Reactance of Primary in Secondary using Equivalent Reactance from Secondary Side
​ LaTeX ​ Go Reactance of Primary in Secondary = Equivalent Reactance from Secondary-Secondary Leakage Reactance
Reactance of Secondary in Primary using Equivalent Reactance from Primary Side
​ LaTeX ​ Go Reactance of Secondary in Primary = Equivalent Reactance from Primary-Primary Leakage Reactance
Primary Leakage Reactance using Equivalent Reactance from Primary Side
​ LaTeX ​ Go Primary Leakage Reactance = Equivalent Reactance from Primary-Reactance of Secondary in Primary

Transformer Circuit Calculators

Equivalent Reactance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary
Equivalent Reactance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Reactance from Primary = Primary Leakage Reactance+Reactance of Secondary in Primary
Primary Leakage Reactance
​ LaTeX ​ Go Primary Leakage Reactance = Reactance of Primary in Secondary/(Transformation Ratio^2)
Reactance of Primary Winding in Secondary
​ LaTeX ​ Go Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2

Reactance of Primary Winding in Secondary Formula

​LaTeX ​Go
Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2
X'1 = XL1*K^2

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Reactance of Primary Winding in Secondary?

Reactance of Primary Winding in Secondary calculator uses Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2 to calculate the Reactance of Primary in Secondary, The Reactance of Primary Winding in Secondary formula is defined as is the reactance that is in Secondary because of the primary winding. Reactance of Primary in Secondary is denoted by X'1 symbol.

How to calculate Reactance of Primary Winding in Secondary using this online calculator? To use this online calculator for Reactance of Primary Winding in Secondary, enter Primary Leakage Reactance (XL1) & Transformation Ratio (K) and hit the calculate button. Here is how the Reactance of Primary Winding in Secondary calculation can be explained with given input values -> 1.2672 = 0.88*1.2^2.

FAQ

What is Reactance of Primary Winding in Secondary?
The Reactance of Primary Winding in Secondary formula is defined as is the reactance that is in Secondary because of the primary winding and is represented as X'1 = XL1*K^2 or Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2. Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding & The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
How to calculate Reactance of Primary Winding in Secondary?
The Reactance of Primary Winding in Secondary formula is defined as is the reactance that is in Secondary because of the primary winding is calculated using Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2. To calculate Reactance of Primary Winding in Secondary, you need Primary Leakage Reactance (XL1) & Transformation Ratio (K). With our tool, you need to enter the respective value for Primary Leakage Reactance & Transformation Ratio and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Reactance of Primary in Secondary?
In this formula, Reactance of Primary in Secondary uses Primary Leakage Reactance & Transformation Ratio. We can use 1 other way(s) to calculate the same, which is/are as follows -