Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids Solution

STEP 0: Pre-Calculation Summary
Formula Used
Rate Constant based on Weight of Catalyst = ln(Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)*(1/exp((ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Plug Flow*Time Interval)))
k' = ln(CA0/CA)*(1/exp((ln(𝛕 ')-kd,PF*t)))
This formula uses 2 Functions, 6 Variables
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
exp - n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable., exp(Number)
Variables Used
Rate Constant based on Weight of Catalyst - (Measured in 1 Per Second) - The Rate Constant based on Weight of Catalyst is a specific form of expressing the rate constant in a catalytic reaction with respect to the mass of the catalyst.
Initial Conc. for 1st Order Catalyzed Reactions - (Measured in Mole per Cubic Meter) - Initial Conc. for 1st Order Catalyzed Reactions is the first measured Concentration of a Compound in a Substance.
Reactant Concentration - (Measured in Mole per Cubic Meter) - Reactant concentration is a measure of the quantity of a specific reactant in relation to the total volume or mass of the system in which a chemical reaction is taking place.
Space Time for 1st Order Catalyzed Reactions - (Measured in Second) - Space Time for 1st Order Catalyzed Reactions is a parameter used to quantify the time required for a given volume of reactant to pass through a catalytic reactor.
Rate of Deactivation for Plug Flow - (Measured in 1 Per Second) - Rate of Deactivation for Plug Flow refers to the change in activity or effectiveness of a catalyst over time in a plug flow reactor configuration.
Time Interval - (Measured in Second) - A Time Interval is the amount of time required for the change from initial to the final state.
STEP 1: Convert Input(s) to Base Unit
Initial Conc. for 1st Order Catalyzed Reactions: 80 Mole per Cubic Meter --> 80 Mole per Cubic Meter No Conversion Required
Reactant Concentration: 24.1 Mole per Cubic Meter --> 24.1 Mole per Cubic Meter No Conversion Required
Space Time for 1st Order Catalyzed Reactions: 2.72 Second --> 2.72 Second No Conversion Required
Rate of Deactivation for Plug Flow: 0.26 1 Per Second --> 0.26 1 Per Second No Conversion Required
Time Interval: 3 Second --> 3 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
k' = ln(CA0/CA)*(1/exp((ln(𝛕 ')-kd,PF*t))) --> ln(80/24.1)*(1/exp((ln(2.72)-0.26*3)))
Evaluating ... ...
k' = 0.962265697511821
STEP 3: Convert Result to Output's Unit
0.962265697511821 1 Per Second --> No Conversion Required
FINAL ANSWER
0.962265697511821 0.962266 1 Per Second <-- Rate Constant based on Weight of Catalyst
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Pavan Kumar
Anurag Group of Institutions (AGI), Hyderabad
Pavan Kumar has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Harsh Kadam
Shri Guru Gobind Singhji Institute of Engineering and Technology (SGGS), Nanded
Harsh Kadam has verified this Calculator and 3 more calculators!

Deactivating Catalysts Calculators

Weight of Catalyst in Batch Solids and Batch Fluids
​ LaTeX ​ Go Weight of Catalyst in Deactivation of Catalyst = ((Volume of Reactor*Rate of Deactivation)/Rate Constant based on Weight of Catalyst)*exp(ln(ln(Reactant Concentration/Concentration at Infinite Time))+Rate of Deactivation*Time Interval)
Deactivation rate for Batch Solids and Mixed Changing Flow of Fluids
​ LaTeX ​ Go Rate of Deactivation for Mixed Flow = (ln(Space Time for 1st Order Catalyzed Reactions)-ln((Initial Conc. for 1st Order Catalyzed Reactions-Reactant Concentration)/(Rate Constant based on Weight of Catalyst*Reactant Concentration)))/Time Interval
Deactivation Rate in Batch Solids and Mixed Constant Flow of Fluids
​ LaTeX ​ Go Rate of Deactivation for Mixed Flow = (ln(Rate Constant based on Weight of Catalyst*Space Time for 1st Order Catalyzed Reactions)-ln((Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)-1))/Time Interval
Activity of Catalyst
​ LaTeX ​ Go Activity of Catalyst = -(Rate at which Pellet converts Reactant A)/-(Rate of Reaction of A with a Fresh Pellet)

Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids Formula

​LaTeX ​Go
Rate Constant based on Weight of Catalyst = ln(Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)*(1/exp((ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Plug Flow*Time Interval)))
k' = ln(CA0/CA)*(1/exp((ln(𝛕 ')-kd,PF*t)))

What are Batch Solids and Plug Flow of Fluids?

Batch solids refer to solid materials that are processed in a batch mode, meaning that a specific quantity of material is treated or transformed at once in a defined batch or lot. In a plug flow, the fluid moves in a well-defined, continuous "plug" without significant mixing or radial variation in velocity. This is in contrast to other flow patterns such as laminar flow and turbulent flow.

What is Deactivation of Catalyst?

Catalyst deactivation refers to a gradual loss of catalytic activity over time, leading to a decline in the catalyst's effectiveness in promoting a chemical reaction. This phenomenon can occur due to various factors, and understanding the mechanisms of catalyst deactivation is crucial for optimizing and extending the lifespan of catalysts in industrial processes.

How to Calculate Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids?

Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids calculator uses Rate Constant based on Weight of Catalyst = ln(Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)*(1/exp((ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Plug Flow*Time Interval))) to calculate the Rate Constant based on Weight of Catalyst, The Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids formula is defined as Rate Constant Calculated when the Batch Solids and Plug Flow of Fluids are Considered in the Reactors, at Deactivation of Catalyst. Rate Constant based on Weight of Catalyst is denoted by k' symbol.

How to calculate Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids using this online calculator? To use this online calculator for Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids, enter Initial Conc. for 1st Order Catalyzed Reactions (CA0), Reactant Concentration (CA), Space Time for 1st Order Catalyzed Reactions (𝛕 '), Rate of Deactivation for Plug Flow (kd,PF) & Time Interval (t) and hit the calculate button. Here is how the Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids calculation can be explained with given input values -> 0.962266 = ln(80/24.1)*(1/exp((ln(2.72)-0.26*3))).

FAQ

What is Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids?
The Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids formula is defined as Rate Constant Calculated when the Batch Solids and Plug Flow of Fluids are Considered in the Reactors, at Deactivation of Catalyst and is represented as k' = ln(CA0/CA)*(1/exp((ln(𝛕 ')-kd,PF*t))) or Rate Constant based on Weight of Catalyst = ln(Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)*(1/exp((ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Plug Flow*Time Interval))). Initial Conc. for 1st Order Catalyzed Reactions is the first measured Concentration of a Compound in a Substance, Reactant concentration is a measure of the quantity of a specific reactant in relation to the total volume or mass of the system in which a chemical reaction is taking place, Space Time for 1st Order Catalyzed Reactions is a parameter used to quantify the time required for a given volume of reactant to pass through a catalytic reactor, Rate of Deactivation for Plug Flow refers to the change in activity or effectiveness of a catalyst over time in a plug flow reactor configuration & A Time Interval is the amount of time required for the change from initial to the final state.
How to calculate Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids?
The Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids formula is defined as Rate Constant Calculated when the Batch Solids and Plug Flow of Fluids are Considered in the Reactors, at Deactivation of Catalyst is calculated using Rate Constant based on Weight of Catalyst = ln(Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)*(1/exp((ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Plug Flow*Time Interval))). To calculate Rate Constant based on Weight of Catalyst in Batch Solids and Plug Changing Flow of Fluids, you need Initial Conc. for 1st Order Catalyzed Reactions (CA0), Reactant Concentration (CA), Space Time for 1st Order Catalyzed Reactions (𝛕 '), Rate of Deactivation for Plug Flow (kd,PF) & Time Interval (t). With our tool, you need to enter the respective value for Initial Conc. for 1st Order Catalyzed Reactions, Reactant Concentration, Space Time for 1st Order Catalyzed Reactions, Rate of Deactivation for Plug Flow & Time Interval and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Rate Constant based on Weight of Catalyst?
In this formula, Rate Constant based on Weight of Catalyst uses Initial Conc. for 1st Order Catalyzed Reactions, Reactant Concentration, Space Time for 1st Order Catalyzed Reactions, Rate of Deactivation for Plug Flow & Time Interval. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Rate Constant based on Weight of Catalyst = ((Volume of Reactor*Rate of Deactivation)/Weight of Catalyst in Deactivation of Catalyst)*exp(ln(ln(Reactant Concentration/Concentration at Infinite Time))+Rate of Deactivation*Time Interval)
  • Rate Constant based on Weight of Catalyst = exp(ln((Initial Conc. for 1st Order Catalyzed Reactions/Reactant Concentration)-1)+Rate of Deactivation for Mixed Flow*Time Interval)/Space Time for 1st Order Catalyzed Reactions
  • Rate Constant based on Weight of Catalyst = (Initial Conc. for 1st Order Catalyzed Reactions-Reactant Concentration)/(Reactant Concentration*exp(ln(Space Time for 1st Order Catalyzed Reactions)-Rate of Deactivation for Mixed Flow*Time Interval))