Rainfall Infiltration Factor when Recharge from Rainfall is Considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season)
f = Rrfm/(Acr*Pnm)
This formula uses 4 Variables
Variables Used
Rainfall Infiltration Factor - The Rainfall Infiltration Factor refers to the measure of the rate at which water from rainfall penetrates into the soil, a critical parameter, influencing design and management of water resources.
Recharge from Rainfall in Monsoon Season - (Measured in Cubic Meter per Second) - Recharge from Rainfall in Monsoon Season is the infiltration and percolation of rainwater into subsurface aquifers, primarily occurring during the monsoon period when rainfall is significantly higher.
Area of Computation for Recharge - (Measured in Square Meter) - The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources.
Normal Rainfall in Monsoon Season - (Measured in Meter) - The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
STEP 1: Convert Input(s) to Base Unit
Recharge from Rainfall in Monsoon Season: 7 Cubic Meter per Second --> 7 Cubic Meter per Second No Conversion Required
Area of Computation for Recharge: 13.3 Square Meter --> 13.3 Square Meter No Conversion Required
Normal Rainfall in Monsoon Season: 0.024 Meter --> 0.024 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = Rrfm/(Acr*Pnm) --> 7/(13.3*0.024)
Evaluating ... ...
f = 21.9298245614035
STEP 3: Convert Result to Output's Unit
21.9298245614035 --> No Conversion Required
FINAL ANSWER
21.9298245614035 21.92982 <-- Rainfall Infiltration Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

4 Rainfall Infiltration Method Calculators

Rainfall Infiltration Factor when Recharge from Rainfall is Considered
​ Go Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season)
Catchment Area when Recharge from Rainfall is Considered
​ Go Area of Computation for Recharge = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Normal Rainfall in Monsoon Season)
Normal Rainfall in Monsoon Season
​ Go Normal Rainfall in Monsoon Season = Recharge from Rainfall in Monsoon Season/(Rainfall Infiltration Factor*Area of Computation for Recharge)
Recharge from Rainfall in Monsoon Season by Rainfall Infiltration Method
​ Go Recharge from Rainfall in Monsoon Season = Rainfall Infiltration Factor*Area of Computation for Recharge*Normal Rainfall in Monsoon Season

Rainfall Infiltration Factor when Recharge from Rainfall is Considered Formula

Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season)
f = Rrfm/(Acr*Pnm)

What is Recharge in Hydrology?

Groundwater recharge or deep drainage or deep percolation is a hydrologic process, where water moves downward from surface water to groundwater. Recharge is the primary method through which water enters an aquifer.

How to Calculate Rainfall Infiltration Factor when Recharge from Rainfall is Considered?

Rainfall Infiltration Factor when Recharge from Rainfall is Considered calculator uses Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season) to calculate the Rainfall Infiltration Factor, The Rainfall Infiltration Factor when Recharge from Rainfall is Considered formula is defined as a dimensionless coefficient used in hydrology to quantify the proportion of rainfall that infiltrates into the ground, as opposed to running off the surface or evaporating. This factor is crucial in calculating the recharge of groundwater from rainfall. Rainfall Infiltration Factor is denoted by f symbol.

How to calculate Rainfall Infiltration Factor when Recharge from Rainfall is Considered using this online calculator? To use this online calculator for Rainfall Infiltration Factor when Recharge from Rainfall is Considered, enter Recharge from Rainfall in Monsoon Season (Rrfm), Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm) and hit the calculate button. Here is how the Rainfall Infiltration Factor when Recharge from Rainfall is Considered calculation can be explained with given input values -> 21.92982 = 7/(13.3*0.024).

FAQ

What is Rainfall Infiltration Factor when Recharge from Rainfall is Considered?
The Rainfall Infiltration Factor when Recharge from Rainfall is Considered formula is defined as a dimensionless coefficient used in hydrology to quantify the proportion of rainfall that infiltrates into the ground, as opposed to running off the surface or evaporating. This factor is crucial in calculating the recharge of groundwater from rainfall and is represented as f = Rrfm/(Acr*Pnm) or Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season). Recharge from Rainfall in Monsoon Season is the infiltration and percolation of rainwater into subsurface aquifers, primarily occurring during the monsoon period when rainfall is significantly higher, The Area of Computation for Recharge refers to the catchment area where the amount of water infiltrating the ground and replenishing aquifers is calculated, crucial for managing groundwater resources & The Normal Rainfall in Monsoon Season refers to the statistical average of rainfall measured over a specified period, typically 30 years, during the monsoon months in a given region.
How to calculate Rainfall Infiltration Factor when Recharge from Rainfall is Considered?
The Rainfall Infiltration Factor when Recharge from Rainfall is Considered formula is defined as a dimensionless coefficient used in hydrology to quantify the proportion of rainfall that infiltrates into the ground, as opposed to running off the surface or evaporating. This factor is crucial in calculating the recharge of groundwater from rainfall is calculated using Rainfall Infiltration Factor = Recharge from Rainfall in Monsoon Season/(Area of Computation for Recharge*Normal Rainfall in Monsoon Season). To calculate Rainfall Infiltration Factor when Recharge from Rainfall is Considered, you need Recharge from Rainfall in Monsoon Season (Rrfm), Area of Computation for Recharge (Acr) & Normal Rainfall in Monsoon Season (Pnm). With our tool, you need to enter the respective value for Recharge from Rainfall in Monsoon Season, Area of Computation for Recharge & Normal Rainfall in Monsoon Season and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!