Pumping Power Required in Heat Exchanger Given Pressure Drop Solution

STEP 0: Pre-Calculation Summary
Formula Used
Pumping Power = (Mass Flowrate*Tube Side Pressure Drop)/Fluid Density
Pp = (Mflow*ΔPTube Side)/ρfluid
This formula uses 4 Variables
Variables Used
Pumping Power - (Measured in Watt) - Pumping Power in a heat exchanger refers to the energy required to circulate the heat transfer fluid (typically a liquid) through the exchanger.
Mass Flowrate - (Measured in Kilogram per Second) - Mass Flowrate is the mass of a substance that passes per unit of time.
Tube Side Pressure Drop - (Measured in Pascal) - Tube Side Pressure Drop is the difference between inlet and outlet pressure of the tube side fluid in a shell and tube heat exchanger.
Fluid Density - (Measured in Kilogram per Cubic Meter) - Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
STEP 1: Convert Input(s) to Base Unit
Mass Flowrate: 14 Kilogram per Second --> 14 Kilogram per Second No Conversion Required
Tube Side Pressure Drop: 186854.6 Pascal --> 186854.6 Pascal No Conversion Required
Fluid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pp = (Mflow*ΔPTube Side)/ρfluid --> (14*186854.6)/995
Evaluating ... ...
Pp = 2629.10994974874
STEP 3: Convert Result to Output's Unit
2629.10994974874 Watt --> No Conversion Required
FINAL ANSWER
2629.10994974874 2629.11 Watt <-- Pumping Power
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Basic Formulas of Heat Exchanger Designs Calculators

Equivalent Diameter for Triangular Pitch in Heat Exchanger
​ Go Equivalent Diameter = (1.10/Pipe Outer Diameter)*((Tube Pitch^2)-0.917*(Pipe Outer Diameter^2))
Equivalent Diameter for Square Pitch in Heat Exchanger
​ Go Equivalent Diameter = (1.27/Pipe Outer Diameter)*((Tube Pitch^2)-0.785*(Pipe Outer Diameter^2))
Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
​ Go Number of Tubes in Vertical Tube Row = Bundle Diameter/Tube Pitch
Number of Baffles in Shell and Tube Heat Exchanger
​ Go Number of Baffles = (Length of Tube/Baffle Spacing)-1

Pumping Power Required in Heat Exchanger Given Pressure Drop Formula

Pumping Power = (Mass Flowrate*Tube Side Pressure Drop)/Fluid Density
Pp = (Mflow*ΔPTube Side)/ρfluid

What is Pumping Power?

Pumping power in a heat exchanger is the energy required to move the heat transfer fluid through the system. It represents the work done by a pump to circulate the fluid, overcoming resistance and maintaining the desired flow rate.

Pumping power is typically measured in watts or horsepower and is influenced by factors such as flow rate and pressure differential across the heat exchanger. Minimizing pumping power is essential for optimizing the energy efficiency of the heat exchange process.

How to Calculate Pumping Power Required in Heat Exchanger Given Pressure Drop?

Pumping Power Required in Heat Exchanger Given Pressure Drop calculator uses Pumping Power = (Mass Flowrate*Tube Side Pressure Drop)/Fluid Density to calculate the Pumping Power, The Pumping Power Required in Heat Exchanger Given Pressure Drop formula is defined as the energy required by pumps or similar equipment to circulate the heat transfer fluid through the exchanger. Pumping Power is denoted by Pp symbol.

How to calculate Pumping Power Required in Heat Exchanger Given Pressure Drop using this online calculator? To use this online calculator for Pumping Power Required in Heat Exchanger Given Pressure Drop, enter Mass Flowrate (Mflow), Tube Side Pressure Drop (ΔPTube Side) & Fluid Density fluid) and hit the calculate button. Here is how the Pumping Power Required in Heat Exchanger Given Pressure Drop calculation can be explained with given input values -> 2629.11 = (14*186854.6)/995.

FAQ

What is Pumping Power Required in Heat Exchanger Given Pressure Drop?
The Pumping Power Required in Heat Exchanger Given Pressure Drop formula is defined as the energy required by pumps or similar equipment to circulate the heat transfer fluid through the exchanger and is represented as Pp = (Mflow*ΔPTube Side)/ρfluid or Pumping Power = (Mass Flowrate*Tube Side Pressure Drop)/Fluid Density. Mass Flowrate is the mass of a substance that passes per unit of time, Tube Side Pressure Drop is the difference between inlet and outlet pressure of the tube side fluid in a shell and tube heat exchanger & Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
How to calculate Pumping Power Required in Heat Exchanger Given Pressure Drop?
The Pumping Power Required in Heat Exchanger Given Pressure Drop formula is defined as the energy required by pumps or similar equipment to circulate the heat transfer fluid through the exchanger is calculated using Pumping Power = (Mass Flowrate*Tube Side Pressure Drop)/Fluid Density. To calculate Pumping Power Required in Heat Exchanger Given Pressure Drop, you need Mass Flowrate (Mflow), Tube Side Pressure Drop (ΔPTube Side) & Fluid Density fluid). With our tool, you need to enter the respective value for Mass Flowrate, Tube Side Pressure Drop & Fluid Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.