Proportionate Discharge using Discharge when Pipe Running Full Solution

STEP 0: Pre-Calculation Summary
Formula Used
Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full
Pq = q/Q
This formula uses 3 Variables
Variables Used
Proportionate Discharge - Proportionate Discharge is the ratio of discharge while running partially full to running full.
Discharge when Pipe is Running Partially Full - (Measured in Cubic Meter per Second) - Discharge when Pipe is Running Partially Full means water is flowing partially form the pipe.
Discharge when Pipe is Running Full - (Measured in Cubic Meter per Second) - Discharge when Pipe is Running Full means water is flowing through the whole cross-section of pipe.
STEP 1: Convert Input(s) to Base Unit
Discharge when Pipe is Running Partially Full: 17.48 Cubic Meter per Second --> 17.48 Cubic Meter per Second No Conversion Required
Discharge when Pipe is Running Full: 32.5 Cubic Meter per Second --> 32.5 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pq = q/Q --> 17.48/32.5
Evaluating ... ...
Pq = 0.537846153846154
STEP 3: Convert Result to Output's Unit
0.537846153846154 --> No Conversion Required
FINAL ANSWER
0.537846153846154 0.537846 <-- Proportionate Discharge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Proportionate Discharge Calculators

Proportionate Discharge given Central Angle
​ Go Proportionate Discharge = ((Central Angle/(360*pi/180))-(sin(Central Angle)/(2*pi)))*(1-((360*pi/180)*sin(Central Angle))/(2*pi*Central Angle))
Proportionate Discharge given Area of Cross-Section
​ Go Proportionate Discharge = (Velocity in a Partially Running Sewer*Area of Partially Full Sewers)/(Velocity While Running Full*Area of Running Full Sewers)
Discharge when Pipe is Running Full using Proportionate Discharge
​ Go Discharge when Pipe is Running Full = (Discharge when Pipe is Running Partially Full/Proportionate Discharge)
Proportionate Discharge using Discharge when Pipe Running Full
​ Go Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full

Proportionate Discharge using Discharge when Pipe Running Full Formula

Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full
Pq = q/Q

What is velocity when running full flow ?

Velocity when running full flow refers to the speed of fluid moving through a fully filled pipe or channel, typically at maximum capacity. It is influenced by factors like the hydraulic radius, slope, and roughness of the pipe or channel. This velocity is crucial for determining flow efficiency, pressure drop, and potential energy losses. Accurate calculation ensures optimal design and operation of water distribution and sewage systems, preventing issues like surges or inadequate flow rates.

How to Calculate Proportionate Discharge using Discharge when Pipe Running Full?

Proportionate Discharge using Discharge when Pipe Running Full calculator uses Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full to calculate the Proportionate Discharge, The Proportionate Discharge using Discharge when Pipe Running Full is defined as the ratio of the flow rate in a partially filled pipe to the flow rate when the pipe is fully filled. Proportionate Discharge is denoted by Pq symbol.

How to calculate Proportionate Discharge using Discharge when Pipe Running Full using this online calculator? To use this online calculator for Proportionate Discharge using Discharge when Pipe Running Full, enter Discharge when Pipe is Running Partially Full (q) & Discharge when Pipe is Running Full (Q) and hit the calculate button. Here is how the Proportionate Discharge using Discharge when Pipe Running Full calculation can be explained with given input values -> 0.537846 = 17.48/32.5.

FAQ

What is Proportionate Discharge using Discharge when Pipe Running Full?
The Proportionate Discharge using Discharge when Pipe Running Full is defined as the ratio of the flow rate in a partially filled pipe to the flow rate when the pipe is fully filled and is represented as Pq = q/Q or Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full. Discharge when Pipe is Running Partially Full means water is flowing partially form the pipe & Discharge when Pipe is Running Full means water is flowing through the whole cross-section of pipe.
How to calculate Proportionate Discharge using Discharge when Pipe Running Full?
The Proportionate Discharge using Discharge when Pipe Running Full is defined as the ratio of the flow rate in a partially filled pipe to the flow rate when the pipe is fully filled is calculated using Proportionate Discharge = Discharge when Pipe is Running Partially Full/Discharge when Pipe is Running Full. To calculate Proportionate Discharge using Discharge when Pipe Running Full, you need Discharge when Pipe is Running Partially Full (q) & Discharge when Pipe is Running Full (Q). With our tool, you need to enter the respective value for Discharge when Pipe is Running Partially Full & Discharge when Pipe is Running Full and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Proportionate Discharge?
In this formula, Proportionate Discharge uses Discharge when Pipe is Running Partially Full & Discharge when Pipe is Running Full. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Proportionate Discharge = ((Central Angle/(360*pi/180))-(sin(Central Angle)/(2*pi)))*(1-((360*pi/180)*sin(Central Angle))/(2*pi*Central Angle))
  • Proportionate Discharge = (Velocity in a Partially Running Sewer*Area of Partially Full Sewers)/(Velocity While Running Full*Area of Running Full Sewers)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!