Primary Winding Resistance given Impedance of Primary Winding Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2)
R1 = sqrt(Z1^2-XL1^2)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Resistance of Primary - (Measured in Ohm) - Resistance of Primary Winding is the resistance of primary winding.
Impedance of Primary - (Measured in Ohm) - The Impedance of Primary Winding is the impedance you anticipate the device connected to the transformer primary side to have.
Primary Leakage Reactance - (Measured in Ohm) - Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
STEP 1: Convert Input(s) to Base Unit
Impedance of Primary: 18 Ohm --> 18 Ohm No Conversion Required
Primary Leakage Reactance: 0.88 Ohm --> 0.88 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R1 = sqrt(Z1^2-XL1^2) --> sqrt(18^2-0.88^2)
Evaluating ... ...
R1 = 17.9784760199523
STEP 3: Convert Result to Output's Unit
17.9784760199523 Ohm --> No Conversion Required
FINAL ANSWER
17.9784760199523 17.97848 Ohm <-- Resistance of Primary
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Resistance Calculators

Resistance of Primary in Secondary using Equivalent Resistance from Secondary Side
​ LaTeX ​ Go Resistance of Primary in Secondary = Equivalent Resistance from Secondary-Resistance of Secondary in Primary
Equivalent Resistance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Resistance from Secondary = Resistance of Primary in Secondary+Resistance of Secondary
Resistance of Secondary in Primary using Equivalent Resistance from Primary Side
​ LaTeX ​ Go Resistance of Secondary in Primary = Equivalent Resistance from Primary-Resistance of Primary
Equivalent Resistance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Resistance from Primary = Resistance of Secondary in Primary+Resistance of Primary

Transformer Design Calculators

Area of Core given EMF Induced in Secondary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Secondary/(4.44*Supply Frequency*Number of Turns in Secondary*Maximum Flux Density)
Area of Core given EMF Induced in Primary Winding
​ LaTeX ​ Go Area of Core = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary*Maximum Flux Density)
Maximum Flux in Core using Primary Winding
​ LaTeX ​ Go Maximum Core Flux = EMF Induced in Primary/(4.44*Supply Frequency*Number of Turns in Primary)
Maximum Core Flux
​ LaTeX ​ Go Maximum Core Flux = Maximum Flux Density*Area of Core

Primary Winding Resistance given Impedance of Primary Winding Formula

​LaTeX ​Go
Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2)
R1 = sqrt(Z1^2-XL1^2)

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Primary Winding Resistance given Impedance of Primary Winding?

Primary Winding Resistance given Impedance of Primary Winding calculator uses Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2) to calculate the Resistance of Primary, The Primary Winding Resistance given Impedance of Primary Winding formula is defined as the resistance of the primary winding. Resistance of Primary is denoted by R1 symbol.

How to calculate Primary Winding Resistance given Impedance of Primary Winding using this online calculator? To use this online calculator for Primary Winding Resistance given Impedance of Primary Winding, enter Impedance of Primary (Z1) & Primary Leakage Reactance (XL1) and hit the calculate button. Here is how the Primary Winding Resistance given Impedance of Primary Winding calculation can be explained with given input values -> 17.97848 = sqrt(18^2-0.88^2).

FAQ

What is Primary Winding Resistance given Impedance of Primary Winding?
The Primary Winding Resistance given Impedance of Primary Winding formula is defined as the resistance of the primary winding and is represented as R1 = sqrt(Z1^2-XL1^2) or Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2). The Impedance of Primary Winding is the impedance you anticipate the device connected to the transformer primary side to have & Primary leakage reactance of a transformer arises from the fact that all the flux produced by one winding does not link with the other winding.
How to calculate Primary Winding Resistance given Impedance of Primary Winding?
The Primary Winding Resistance given Impedance of Primary Winding formula is defined as the resistance of the primary winding is calculated using Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2). To calculate Primary Winding Resistance given Impedance of Primary Winding, you need Impedance of Primary (Z1) & Primary Leakage Reactance (XL1). With our tool, you need to enter the respective value for Impedance of Primary & Primary Leakage Reactance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistance of Primary?
In this formula, Resistance of Primary uses Impedance of Primary & Primary Leakage Reactance. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Resistance of Primary = (Equivalent Resistance from Secondary-Resistance of Secondary)/(Transformation Ratio^2)
  • Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp