Primary Winding Resistance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2)
R1 = R'1/(K^2)
This formula uses 3 Variables
Variables Used
Resistance of Primary - (Measured in Ohm) - Resistance of Primary Winding is the resistance of primary winding.
Resistance of Primary in Secondary - (Measured in Ohm) - Resistance of Primary in Secondary is the Resistance of Primary winding in Secondary.
Transformation Ratio - The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
STEP 1: Convert Input(s) to Base Unit
Resistance of Primary in Secondary: 25.89 Ohm --> 25.89 Ohm No Conversion Required
Transformation Ratio: 1.2 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R1 = R'1/(K^2) --> 25.89/(1.2^2)
Evaluating ... ...
R1 = 17.9791666666667
STEP 3: Convert Result to Output's Unit
17.9791666666667 Ohm --> No Conversion Required
FINAL ANSWER
17.9791666666667 17.97917 Ohm <-- Resistance of Primary
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Resistance Calculators

Resistance of Primary in Secondary using Equivalent Resistance from Secondary Side
​ LaTeX ​ Go Resistance of Primary in Secondary = Equivalent Resistance from Secondary-Resistance of Secondary in Primary
Equivalent Resistance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Resistance from Secondary = Resistance of Primary in Secondary+Resistance of Secondary
Resistance of Secondary in Primary using Equivalent Resistance from Primary Side
​ LaTeX ​ Go Resistance of Secondary in Primary = Equivalent Resistance from Primary-Resistance of Primary
Equivalent Resistance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Resistance from Primary = Resistance of Secondary in Primary+Resistance of Primary

Transformer Circuit Calculators

Equivalent Reactance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary
Equivalent Reactance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Reactance from Primary = Primary Leakage Reactance+Reactance of Secondary in Primary
Primary Leakage Reactance
​ LaTeX ​ Go Primary Leakage Reactance = Reactance of Primary in Secondary/(Transformation Ratio^2)
Reactance of Primary Winding in Secondary
​ LaTeX ​ Go Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2

Primary Winding Resistance Formula

​LaTeX ​Go
Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2)
R1 = R'1/(K^2)

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Primary Winding Resistance?

Primary Winding Resistance calculator uses Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2) to calculate the Resistance of Primary, The Primary Winding Resistance formula is defined as the resistance of primary windings. its SI unit is ohms. It is useful for finding Resistance to the primary winding in the secondary winding. Resistance of Primary is denoted by R1 symbol.

How to calculate Primary Winding Resistance using this online calculator? To use this online calculator for Primary Winding Resistance, enter Resistance of Primary in Secondary (R'1) & Transformation Ratio (K) and hit the calculate button. Here is how the Primary Winding Resistance calculation can be explained with given input values -> 17.97917 = 25.89/(1.2^2).

FAQ

What is Primary Winding Resistance?
The Primary Winding Resistance formula is defined as the resistance of primary windings. its SI unit is ohms. It is useful for finding Resistance to the primary winding in the secondary winding and is represented as R1 = R'1/(K^2) or Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2). Resistance of Primary in Secondary is the Resistance of Primary winding in Secondary & The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
How to calculate Primary Winding Resistance?
The Primary Winding Resistance formula is defined as the resistance of primary windings. its SI unit is ohms. It is useful for finding Resistance to the primary winding in the secondary winding is calculated using Resistance of Primary = Resistance of Primary in Secondary/(Transformation Ratio^2). To calculate Primary Winding Resistance, you need Resistance of Primary in Secondary (R'1) & Transformation Ratio (K). With our tool, you need to enter the respective value for Resistance of Primary in Secondary & Transformation Ratio and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resistance of Primary?
In this formula, Resistance of Primary uses Resistance of Primary in Secondary & Transformation Ratio. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Resistance of Primary = (Equivalent Resistance from Secondary-Resistance of Secondary)/(Transformation Ratio^2)
  • Resistance of Primary = sqrt(Impedance of Primary^2-Primary Leakage Reactance^2)