Primary Voltage given Voltage Transformation Ratio Solution

STEP 0: Pre-Calculation Summary
Formula Used
Primary Voltage = Secondary Voltage/Transformation Ratio
V1 = V2/K
This formula uses 3 Variables
Variables Used
Primary Voltage - (Measured in Volt) - Primary Voltage means the level of voltage at facilities at which electric power is taken or delivered, generally at a level between 12 kV and 33 kV, but always between 2 kV and 50 kV.
Secondary Voltage - (Measured in Volt) - Secondary Voltage is defined as the voltage on the secondary side of a transformer or the side at which load is connected.
Transformation Ratio - The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
STEP 1: Convert Input(s) to Base Unit
Secondary Voltage: 288 Volt --> 288 Volt No Conversion Required
Transformation Ratio: 1.2 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V1 = V2/K --> 288/1.2
Evaluating ... ...
V1 = 240
STEP 3: Convert Result to Output's Unit
240 Volt --> No Conversion Required
FINAL ANSWER
240 Volt <-- Primary Voltage
(Calculation completed in 00.005 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Voltage and EMF Calculators

Output Voltage given EMF Induced in Secondary Winding
​ LaTeX ​ Go Secondary Voltage = EMF Induced in Secondary-Secondary Current*Impedance of Secondary
Input Voltage when EMF Induced in Primary Winding
​ LaTeX ​ Go Primary Voltage = EMF Induced in Primary+Primary Current*Impedance of Primary
EMF Induced in Secondary Winding given Voltage Transformation Ratio
​ LaTeX ​ Go EMF Induced in Secondary = EMF Induced in Primary*Transformation Ratio
EMF Induced in Primary Winding given Voltage Transformation Ratio
​ LaTeX ​ Go EMF Induced in Primary = EMF Induced in Secondary/Transformation Ratio

Transformer Circuit Calculators

Equivalent Reactance of Transformer from Secondary Side
​ LaTeX ​ Go Equivalent Reactance from Secondary = Secondary Leakage Reactance+Reactance of Primary in Secondary
Equivalent Reactance of Transformer from Primary Side
​ LaTeX ​ Go Equivalent Reactance from Primary = Primary Leakage Reactance+Reactance of Secondary in Primary
Primary Leakage Reactance
​ LaTeX ​ Go Primary Leakage Reactance = Reactance of Primary in Secondary/(Transformation Ratio^2)
Reactance of Primary Winding in Secondary
​ LaTeX ​ Go Reactance of Primary in Secondary = Primary Leakage Reactance*Transformation Ratio^2

Primary Voltage given Voltage Transformation Ratio Formula

​LaTeX ​Go
Primary Voltage = Secondary Voltage/Transformation Ratio
V1 = V2/K

What is transformer transformation ratio?

It is actually defined as a transformer. Transformation Ratio (K) is defined as the ratio of the EMF in the secondary coil to that in the primary coil. Due to the resistance in the windings and some leakage flux, there is some loss in voltage. This is called Voltage Drop.

How to Calculate Primary Voltage given Voltage Transformation Ratio?

Primary Voltage given Voltage Transformation Ratio calculator uses Primary Voltage = Secondary Voltage/Transformation Ratio to calculate the Primary Voltage, The Primary Voltage given Voltage Transformation Ratio formula is defined as the voltage which is on the primary side of the transformer. Primary Voltage is denoted by V1 symbol.

How to calculate Primary Voltage given Voltage Transformation Ratio using this online calculator? To use this online calculator for Primary Voltage given Voltage Transformation Ratio, enter Secondary Voltage (V2) & Transformation Ratio (K) and hit the calculate button. Here is how the Primary Voltage given Voltage Transformation Ratio calculation can be explained with given input values -> 240 = 288/1.2.

FAQ

What is Primary Voltage given Voltage Transformation Ratio?
The Primary Voltage given Voltage Transformation Ratio formula is defined as the voltage which is on the primary side of the transformer and is represented as V1 = V2/K or Primary Voltage = Secondary Voltage/Transformation Ratio. Secondary Voltage is defined as the voltage on the secondary side of a transformer or the side at which load is connected & The Transformation Ratio of the transformer is used to find the relation between primary voltage and secondary voltage.
How to calculate Primary Voltage given Voltage Transformation Ratio?
The Primary Voltage given Voltage Transformation Ratio formula is defined as the voltage which is on the primary side of the transformer is calculated using Primary Voltage = Secondary Voltage/Transformation Ratio. To calculate Primary Voltage given Voltage Transformation Ratio, you need Secondary Voltage (V2) & Transformation Ratio (K). With our tool, you need to enter the respective value for Secondary Voltage & Transformation Ratio and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Primary Voltage?
In this formula, Primary Voltage uses Secondary Voltage & Transformation Ratio. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Primary Voltage = EMF Induced in Primary+Primary Current*Impedance of Primary
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!