Primary Impedance in Miller Capacitance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain))
Z1 = Zt/(1-(Av))
This formula uses 3 Variables
Variables Used
Impedance of Primary Winding - (Measured in Ohm) - Impedance of Primary Winding refers to the total opposition or resistance to the flow of alternating current in the primary coil.
Total Impedance - (Measured in Ohm) - Total Impedance refers to the overall opposition or resistance to the flow of alternating current (AC) in an electrical circuit.
Voltage Gain - Voltage Gain refers to the mathematical relationship or equation that describes how an amplifier modifies the input voltage to produce an output voltage.
STEP 1: Convert Input(s) to Base Unit
Total Impedance: 1.23 Kilohm --> 1230 Ohm (Check conversion ​here)
Voltage Gain: -10.25 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z1 = Zt/(1-(Av)) --> 1230/(1-((-10.25)))
Evaluating ... ...
Z1 = 109.333333333333
STEP 3: Convert Result to Output's Unit
109.333333333333 Ohm -->0.109333333333333 Kilohm (Check conversion ​here)
FINAL ANSWER
0.109333333333333 0.109333 Kilohm <-- Impedance of Primary Winding
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ritwik Tripathi
Vellore Institute of Technology (VIT Vellore), Vellore
Ritwik Tripathi has created this Calculator and 10+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

Miller’s Theorem Calculators

Miller Capacitance
​ LaTeX ​ Go Miller Capacitance = Gate to Drain Capacitance*(1+1/(Transconductance*Load Resistance))
Current at Primary Node of Amplifier
​ LaTeX ​ Go Current in Primary Conductor = A-Phase Voltage/Impedance of Primary Winding
Change in Drain Current
​ LaTeX ​ Go Change in Drain Current = -A-Phase Voltage/Impedance of Secondary Winding
Primary Impedance in Miller Capacitance
​ LaTeX ​ Go Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain))

Primary Impedance in Miller Capacitance Formula

​LaTeX ​Go
Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain))
Z1 = Zt/(1-(Av))

What are the applications of calculating Miller Capacitance?

Miller capacitance calculations are vital in electronics for amplifier stability, frequency response and circuit design.They're crucial in analyzing feedback systems, optimizing filter response, ensuring stability in transistor amplifiers, and maintaining signal integrity in high-speed circuits, impacting various applications from amplifier design to RF circuits and power electronics.

How to Calculate Primary Impedance in Miller Capacitance?

Primary Impedance in Miller Capacitance calculator uses Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain)) to calculate the Impedance of Primary Winding, The Primary Impedance in Miller Capacitance formula is defined as the impedance seen at the input or output of an amplifier due to the presence of a capacitance in the circuit. It takes into account the capacitance value and the gain of the amplifier. Impedance of Primary Winding is denoted by Z1 symbol.

How to calculate Primary Impedance in Miller Capacitance using this online calculator? To use this online calculator for Primary Impedance in Miller Capacitance, enter Total Impedance (Zt) & Voltage Gain (Av) and hit the calculate button. Here is how the Primary Impedance in Miller Capacitance calculation can be explained with given input values -> 0.000109 = 1230/(1-((-10.25))).

FAQ

What is Primary Impedance in Miller Capacitance?
The Primary Impedance in Miller Capacitance formula is defined as the impedance seen at the input or output of an amplifier due to the presence of a capacitance in the circuit. It takes into account the capacitance value and the gain of the amplifier and is represented as Z1 = Zt/(1-(Av)) or Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain)). Total Impedance refers to the overall opposition or resistance to the flow of alternating current (AC) in an electrical circuit & Voltage Gain refers to the mathematical relationship or equation that describes how an amplifier modifies the input voltage to produce an output voltage.
How to calculate Primary Impedance in Miller Capacitance?
The Primary Impedance in Miller Capacitance formula is defined as the impedance seen at the input or output of an amplifier due to the presence of a capacitance in the circuit. It takes into account the capacitance value and the gain of the amplifier is calculated using Impedance of Primary Winding = Total Impedance/(1-(Voltage Gain)). To calculate Primary Impedance in Miller Capacitance, you need Total Impedance (Zt) & Voltage Gain (Av). With our tool, you need to enter the respective value for Total Impedance & Voltage Gain and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!