Primary Current using Primary Parameters Solution

STEP 0: Pre-Calculation Summary
Formula Used
Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary
I1 = (V1-E1)/Z1
This formula uses 4 Variables
Variables Used
Primary Current - (Measured in Ampere) - Primary Current is the current which is flow in the primary winding of the transformer. The primary current of the transformer is dictated by the load current.
Primary Voltage - (Measured in Volt) - Primary Voltage means the level of voltage at facilities at which electric power is taken or delivered, generally at a level between 12 kV and 33 kV, but always between 2 kV and 50 kV.
EMF Induced in Primary - (Measured in Volt) - EMF Induced in Primary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil.
Impedance of Primary - (Measured in Ohm) - The Impedance of Primary Winding is the impedance you anticipate the device connected to the transformer primary side to have.
STEP 1: Convert Input(s) to Base Unit
Primary Voltage: 240 Volt --> 240 Volt No Conversion Required
EMF Induced in Primary: 13.2 Volt --> 13.2 Volt No Conversion Required
Impedance of Primary: 18 Ohm --> 18 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
I1 = (V1-E1)/Z1 --> (240-13.2)/18
Evaluating ... ...
I1 = 12.6
STEP 3: Convert Result to Output's Unit
12.6 Ampere --> No Conversion Required
FINAL ANSWER
12.6 Ampere <-- Primary Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 50+ more calculators!

Current Calculators

Secondary Current using Secondary Parameters
​ LaTeX ​ Go Secondary Current = (EMF Induced in Secondary-Secondary Voltage)/Impedance of Secondary
Primary Current using Primary Parameters
​ LaTeX ​ Go Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary
Secondary Current given Secondary Leakage Reactance
​ LaTeX ​ Go Secondary Current = Self Induced EMF in Secondary/Secondary Leakage Reactance
Primary Current given Primary Leakage Reactance
​ LaTeX ​ Go Primary Current = Self Induced EMF in Primary/Primary Leakage Reactance

Primary Current using Primary Parameters Formula

​LaTeX ​Go
Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary
I1 = (V1-E1)/Z1

What type of windings are used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Primary Current using Primary Parameters?

Primary Current using Primary Parameters calculator uses Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary to calculate the Primary Current, The Primary Current using Primary Parameters formula is defined as the current that flows into the primary winding. Primary Current is denoted by I1 symbol.

How to calculate Primary Current using Primary Parameters using this online calculator? To use this online calculator for Primary Current using Primary Parameters, enter Primary Voltage (V1), EMF Induced in Primary (E1) & Impedance of Primary (Z1) and hit the calculate button. Here is how the Primary Current using Primary Parameters calculation can be explained with given input values -> 12.6 = (240-13.2)/18.

FAQ

What is Primary Current using Primary Parameters?
The Primary Current using Primary Parameters formula is defined as the current that flows into the primary winding and is represented as I1 = (V1-E1)/Z1 or Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary. Primary Voltage means the level of voltage at facilities at which electric power is taken or delivered, generally at a level between 12 kV and 33 kV, but always between 2 kV and 50 kV, EMF Induced in Primary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil & The Impedance of Primary Winding is the impedance you anticipate the device connected to the transformer primary side to have.
How to calculate Primary Current using Primary Parameters?
The Primary Current using Primary Parameters formula is defined as the current that flows into the primary winding is calculated using Primary Current = (Primary Voltage-EMF Induced in Primary)/Impedance of Primary. To calculate Primary Current using Primary Parameters, you need Primary Voltage (V1), EMF Induced in Primary (E1) & Impedance of Primary (Z1). With our tool, you need to enter the respective value for Primary Voltage, EMF Induced in Primary & Impedance of Primary and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Primary Current?
In this formula, Primary Current uses Primary Voltage, EMF Induced in Primary & Impedance of Primary. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Primary Current = Self Induced EMF in Primary/Primary Leakage Reactance
  • Primary Current = Secondary Current*Transformation Ratio
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!