Pressure Drop in Plate Type Heat Exchanger given Reynolds Number Solution

STEP 0: Pre-Calculation Summary
Formula Used
Plate Pressure Drop = 8*(0.6*(Reynold Number^(-0.3)))*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2)/2)
ΔPp = 8*(0.6*(Re^(-0.3)))*(Lp/De)*(ρfluid*(up^2)/2)
This formula uses 6 Variables
Variables Used
Plate Pressure Drop - (Measured in Pascal) - Plate Pressure Drop refers to the loss of fluid pressure as the fluid flows through the channels formed by the plates.
Reynold Number - Reynold Number is defined as the ratio of inertial force to the viscous force of fluid.
Path Length - (Measured in Meter) - Path Length refers to the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates.
Equivalent Diameter - (Measured in Meter) - Equivalent diameter represents a single characteristic length that takes into account the cross-sectional shape and flow path of a non-circular or irregularly shaped channel or duct.
Fluid Density - (Measured in Kilogram per Cubic Meter) - Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Channel Velocity - (Measured in Meter per Second) - Channel Velocity refers to the average velocity of the fluid flowing through the channels formed by adjacent plates.
STEP 1: Convert Input(s) to Base Unit
Reynold Number: 23.159 --> No Conversion Required
Path Length: 631.47 Millimeter --> 0.63147 Meter (Check conversion ​here)
Equivalent Diameter: 16.528 Millimeter --> 0.016528 Meter (Check conversion ​here)
Fluid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
Channel Velocity: 1.845 Meter per Second --> 1.845 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ΔPp = 8*(0.6*(Re^(-0.3)))*(Lp/De)*(ρfluid*(up^2)/2) --> 8*(0.6*(23.159^(-0.3)))*(0.63147/0.016528)*(995*(1.845^2)/2)
Evaluating ... ...
ΔPp = 120988.346458467
STEP 3: Convert Result to Output's Unit
120988.346458467 Pascal --> No Conversion Required
FINAL ANSWER
120988.346458467 120988.3 Pascal <-- Plate Pressure Drop
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has created this Calculator and 800+ more calculators!
Verifier Image
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 800+ more calculators!

Basic Formulas of Heat Exchanger Designs Calculators

Equivalent Diameter for Triangular Pitch in Heat Exchanger
​ Go Equivalent Diameter = (1.10/Pipe Outer Diameter)*((Tube Pitch^2)-0.917*(Pipe Outer Diameter^2))
Equivalent Diameter for Square Pitch in Heat Exchanger
​ Go Equivalent Diameter = (1.27/Pipe Outer Diameter)*((Tube Pitch^2)-0.785*(Pipe Outer Diameter^2))
Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
​ Go Number of Tubes in Vertical Tube Row = Bundle Diameter/Tube Pitch
Number of Baffles in Shell and Tube Heat Exchanger
​ Go Number of Baffles = (Length of Tube/Baffle Spacing)-1

Pressure Drop in Plate Type Heat Exchanger given Reynolds Number Formula

Plate Pressure Drop = 8*(0.6*(Reynold Number^(-0.3)))*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2)/2)
ΔPp = 8*(0.6*(Re^(-0.3)))*(Lp/De)*(ρfluid*(up^2)/2)

What is the Significance of Plate Pressure Drop in Plate Type Heat Exchanger?

Plate pressure drop in a plate-type heat exchanger refers to the loss of fluid pressure as the fluid flows through the channels formed by the plates. It is a measure of the resistance encountered by the fluid as it moves through the narrow passages between the plates. Plate pressure drop is a critical consideration in the design and operation of plate heat exchangers. Several factors contribute to plate pressure drop, including the fluid velocity, viscosity, flow rate, and the geometric configuration of the plates (such as plate spacing and pattern). Higher fluid velocities and more complex plate arrangements tend to increase pressure drop.

How to Calculate Pressure Drop in Plate Type Heat Exchanger given Reynolds Number?

Pressure Drop in Plate Type Heat Exchanger given Reynolds Number calculator uses Plate Pressure Drop = 8*(0.6*(Reynold Number^(-0.3)))*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2)/2) to calculate the Plate Pressure Drop, The Pressure Drop in Plate Type Heat Exchanger given Reynolds Number formula is defined as the decrease in pressure experienced by the fluid as it travels through the flow channels created by the stacked plates. Plate Pressure Drop is denoted by ΔPp symbol.

How to calculate Pressure Drop in Plate Type Heat Exchanger given Reynolds Number using this online calculator? To use this online calculator for Pressure Drop in Plate Type Heat Exchanger given Reynolds Number, enter Reynold Number (Re), Path Length (Lp), Equivalent Diameter (De), Fluid Density fluid) & Channel Velocity (up) and hit the calculate button. Here is how the Pressure Drop in Plate Type Heat Exchanger given Reynolds Number calculation can be explained with given input values -> 120988.3 = 8*(0.6*(23.159^(-0.3)))*(0.63147/0.016528)*(995*(1.845^2)/2).

FAQ

What is Pressure Drop in Plate Type Heat Exchanger given Reynolds Number?
The Pressure Drop in Plate Type Heat Exchanger given Reynolds Number formula is defined as the decrease in pressure experienced by the fluid as it travels through the flow channels created by the stacked plates and is represented as ΔPp = 8*(0.6*(Re^(-0.3)))*(Lp/De)*(ρfluid*(up^2)/2) or Plate Pressure Drop = 8*(0.6*(Reynold Number^(-0.3)))*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2)/2). Reynold Number is defined as the ratio of inertial force to the viscous force of fluid, Path Length refers to the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates, Equivalent diameter represents a single characteristic length that takes into account the cross-sectional shape and flow path of a non-circular or irregularly shaped channel or duct, Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies & Channel Velocity refers to the average velocity of the fluid flowing through the channels formed by adjacent plates.
How to calculate Pressure Drop in Plate Type Heat Exchanger given Reynolds Number?
The Pressure Drop in Plate Type Heat Exchanger given Reynolds Number formula is defined as the decrease in pressure experienced by the fluid as it travels through the flow channels created by the stacked plates is calculated using Plate Pressure Drop = 8*(0.6*(Reynold Number^(-0.3)))*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2)/2). To calculate Pressure Drop in Plate Type Heat Exchanger given Reynolds Number, you need Reynold Number (Re), Path Length (Lp), Equivalent Diameter (De), Fluid Density fluid) & Channel Velocity (up). With our tool, you need to enter the respective value for Reynold Number, Path Length, Equivalent Diameter, Fluid Density & Channel Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Plate Pressure Drop?
In this formula, Plate Pressure Drop uses Reynold Number, Path Length, Equivalent Diameter, Fluid Density & Channel Velocity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Plate Pressure Drop = 8*Friction Factor*(Path Length/Equivalent Diameter)*(Fluid Density*(Channel Velocity^2))/2
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!