Formula Used
Pressure Drop Correlation Factor = (13.1*((Gas Mass Flux)^2)*Packing Factor*((Fluid Viscosity in Packed Column/Liquid Density)^0.1))/((Vapor Density in Packed Column)*(Liquid Density-Vapor Density in Packed Column))
K4 = (13.1*((Vw)^2)*Fp*((μL/ρL)^0.1))/((ρV)*(ρL-ρV))
This formula uses 6 Variables
Variables Used
Pressure Drop Correlation Factor - Pressure Drop Correlation Factor is the constant that correlates with gas mass flow rates per unit cross sectional area.
Gas Mass Flux - (Measured in Kilogram per Second per Square Meter) - Gas Mass Flux is the mass Flowrate of vapor component per unit cross sectional area of column.
Packing Factor - Packing Factor characterizes the efficiency of the packing material used in a column.
Fluid Viscosity in Packed Column - (Measured in Pascal Second) - Fluid Viscosity in Packed Column is a fundamental property of fluids that characterizes their resistance to flow. It is defined at the bulk temperature of the fluid.
Liquid Density - (Measured in Kilogram per Cubic Meter) - Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Vapor Density in Packed Column - (Measured in Kilogram per Cubic Meter) - Vapor Density in Packed Column is defined as the ratio of mass to the volume of vapor at particular temperature in a Packed Column.
STEP 1: Convert Input(s) to Base Unit
Gas Mass Flux: 1.25781 Kilogram per Second per Square Meter --> 1.25781 Kilogram per Second per Square Meter No Conversion Required
Packing Factor: 0.071 --> No Conversion Required
Fluid Viscosity in Packed Column: 1.005 Pascal Second --> 1.005 Pascal Second No Conversion Required
Liquid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
Vapor Density in Packed Column: 1.71 Kilogram per Cubic Meter --> 1.71 Kilogram per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K4 = (13.1*((Vw)^2)*Fp*((μLL)^0.1))/((ρV)*(ρLV)) --> (13.1*((1.25781)^2)*0.071*((1.005/995)^0.1))/((1.71)*(995-1.71))
Evaluating ... ...
K4 = 0.000434632157061385
STEP 3: Convert Result to Output's Unit
0.000434632157061385 --> No Conversion Required
FINAL ANSWER
0.000434632157061385 0.000435 <-- Pressure Drop Correlation Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Packed Column Designing Calculators

Effective Interfacial Area of Packing using Onda's Method
​ LaTeX ​ Go Effective Interfacial Area = Interfacial Area per Volume*(1-exp((-1.45*((Critical Surface Tension/Liquid Surface Tension)^0.75)*(Liquid Mass Flux/(Interfacial Area per Volume*Fluid Viscosity in Packed Column))^0.1)*(((Liquid Mass Flux)^2*Interfacial Area per Volume)/((Liquid Density)^2*[g]))^-0.05)*(Liquid Mass Flux^2/(Liquid Density*Interfacial Area per Volume*Liquid Surface Tension))^0.2)
Liquid Mass Film Coefficient in Packed Columns
​ LaTeX ​ Go Liquid Phase Mass Transfer Coefficient = 0.0051*((Liquid Mass Flux*Packing Volume/(Effective Interfacial Area*Fluid Viscosity in Packed Column))^(2/3))*((Fluid Viscosity in Packed Column/(Liquid Density*Column Diameter of Packed Column))^(-1/2))*((Interfacial Area per Volume*Packing Size/Packing Volume)^0.4)*((Fluid Viscosity in Packed Column*[g])/Liquid Density)^(1/3)
Log Mean Driving Force Based on Mole Fraction
​ LaTeX ​ Go Log Mean Driving Force = (Solute Gas Mole Fraction-Solute Gas Mole Fraction at Top)/(ln((Solute Gas Mole Fraction-Gas Concentration at Equilibrium)/(Solute Gas Mole Fraction at Top-Gas Concentration at Equilibrium)))
Height of Overall Gas Phase Transfer Unit in Packed Column
​ LaTeX ​ Go Height of Transfer Unit = (Molar Gas Flowrate)/(Overall Gas Phase Mass Transfer Coefficient*Interfacial Area per Volume*Total Pressure)

Pressure Drop Correlation given Vapor Mass Flux and Packing Factor Formula

​LaTeX ​Go
Pressure Drop Correlation Factor = (13.1*((Gas Mass Flux)^2)*Packing Factor*((Fluid Viscosity in Packed Column/Liquid Density)^0.1))/((Vapor Density in Packed Column)*(Liquid Density-Vapor Density in Packed Column))
K4 = (13.1*((Vw)^2)*Fp*((μL/ρL)^0.1))/((ρV)*(ρL-ρV))

What is the significance of Pressure Drop Correlation in Packed Column?

Understanding the pressure drop is crucial in designing packed columns. The pressure drop directly affects the energy requirements and the pumping power needed to circulate the fluids through the column.
When scaling up a process from laboratory-scale to industrial-scale, it's important to consider the pressure drop in the packed column. The correlation helps in estimating how the pressure drop will change as the column size increases, allowing for the proper design of larger-scale equipment.
In some processes, exceeding certain pressure limits can be a safety concern. The pressure drop correlation aids in setting and maintaining safe operating conditions within the column.

How to Calculate Pressure Drop Correlation given Vapor Mass Flux and Packing Factor?

Pressure Drop Correlation given Vapor Mass Flux and Packing Factor calculator uses Pressure Drop Correlation Factor = (13.1*((Gas Mass Flux)^2)*Packing Factor*((Fluid Viscosity in Packed Column/Liquid Density)^0.1))/((Vapor Density in Packed Column)*(Liquid Density-Vapor Density in Packed Column)) to calculate the Pressure Drop Correlation Factor, The Pressure Drop Correlation given Vapor Mass Flux and Packing Factor formula represents the characteristics of the packing material used in the column or bed. It includes parameters like the type of packing, size, shape, and surface area. Pressure Drop Correlation Factor is denoted by K4 symbol.

How to calculate Pressure Drop Correlation given Vapor Mass Flux and Packing Factor using this online calculator? To use this online calculator for Pressure Drop Correlation given Vapor Mass Flux and Packing Factor, enter Gas Mass Flux (Vw), Packing Factor (Fp), Fluid Viscosity in Packed Column L), Liquid Density L) & Vapor Density in Packed Column V) and hit the calculate button. Here is how the Pressure Drop Correlation given Vapor Mass Flux and Packing Factor calculation can be explained with given input values -> 0.000435 = (13.1*((1.25781)^2)*0.071*((1.005/995)^0.1))/((1.71)*(995-1.71)).

FAQ

What is Pressure Drop Correlation given Vapor Mass Flux and Packing Factor?
The Pressure Drop Correlation given Vapor Mass Flux and Packing Factor formula represents the characteristics of the packing material used in the column or bed. It includes parameters like the type of packing, size, shape, and surface area and is represented as K4 = (13.1*((Vw)^2)*Fp*((μLL)^0.1))/((ρV)*(ρLV)) or Pressure Drop Correlation Factor = (13.1*((Gas Mass Flux)^2)*Packing Factor*((Fluid Viscosity in Packed Column/Liquid Density)^0.1))/((Vapor Density in Packed Column)*(Liquid Density-Vapor Density in Packed Column)). Gas Mass Flux is the mass Flowrate of vapor component per unit cross sectional area of column, Packing Factor characterizes the efficiency of the packing material used in a column, Fluid Viscosity in Packed Column is a fundamental property of fluids that characterizes their resistance to flow. It is defined at the bulk temperature of the fluid, Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies & Vapor Density in Packed Column is defined as the ratio of mass to the volume of vapor at particular temperature in a Packed Column.
How to calculate Pressure Drop Correlation given Vapor Mass Flux and Packing Factor?
The Pressure Drop Correlation given Vapor Mass Flux and Packing Factor formula represents the characteristics of the packing material used in the column or bed. It includes parameters like the type of packing, size, shape, and surface area is calculated using Pressure Drop Correlation Factor = (13.1*((Gas Mass Flux)^2)*Packing Factor*((Fluid Viscosity in Packed Column/Liquid Density)^0.1))/((Vapor Density in Packed Column)*(Liquid Density-Vapor Density in Packed Column)). To calculate Pressure Drop Correlation given Vapor Mass Flux and Packing Factor, you need Gas Mass Flux (Vw), Packing Factor (Fp), Fluid Viscosity in Packed Column L), Liquid Density L) & Vapor Density in Packed Column V). With our tool, you need to enter the respective value for Gas Mass Flux, Packing Factor, Fluid Viscosity in Packed Column, Liquid Density & Vapor Density in Packed Column and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!