Power Transmitted using Load Current(Two-Wire Mid-Point Earthed) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC
P = I*2*Vm
This formula uses 3 Variables
Variables Used
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Current Overhead DC - (Measured in Ampere) - Current Overhead DC is defined as the current flowing through the overhead ac supply wire.
Maximum Voltage Overhead DC - (Measured in Volt) - Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
STEP 1: Convert Input(s) to Base Unit
Current Overhead DC: 3.1 Ampere --> 3.1 Ampere No Conversion Required
Maximum Voltage Overhead DC: 60.26 Volt --> 60.26 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = I*2*Vm --> 3.1*2*60.26
Evaluating ... ...
P = 373.612
STEP 3: Convert Result to Output's Unit
373.612 Watt --> No Conversion Required
FINAL ANSWER
373.612 Watt <-- Power Transmitted
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has verified this Calculator and 100+ more calculators!

Power and Power Factor Calculators

Power Transmitted using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)
​ LaTeX ​ Go Power Transmitted = sqrt(Line Losses*Volume of Conductor*(Maximum Voltage Overhead DC^2)/(Resistivity*(Length of Wire DC)^2))
Power Transmitted using Line Losses(Two-Wire Mid-Point Earthed)
​ LaTeX ​ Go Power Transmitted = Maximum Voltage Overhead DC*sqrt(Line Losses*2*Area of Overhead DC Wire/(Resistivity*Length of Wire DC))
Power Transmitted using Load Current(Two-Wire Mid-Point Earthed)
​ LaTeX ​ Go Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC

Power Transmitted using Load Current(Two-Wire Mid-Point Earthed) Formula

​LaTeX ​Go
Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC
P = I*2*Vm

What is the Volume of two-wire mid-point earthed system?

The volume of conductor material required in a two-wire mid-point earthed system is one-fourth of that required in a two-wire dc System with one conductor earthed.

How to Calculate Power Transmitted using Load Current(Two-Wire Mid-Point Earthed)?

Power Transmitted using Load Current(Two-Wire Mid-Point Earthed) calculator uses Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC to calculate the Power Transmitted, The Power Transmitted using Load Current(Two-Wire Mid-point Earthed) formula is defined as proportional to its effective range. The higher the transmit power, the farther a signal can travel, and the more obstructions it can effectively penetrate. Power Transmitted is denoted by P symbol.

How to calculate Power Transmitted using Load Current(Two-Wire Mid-Point Earthed) using this online calculator? To use this online calculator for Power Transmitted using Load Current(Two-Wire Mid-Point Earthed), enter Current Overhead DC (I) & Maximum Voltage Overhead DC (Vm) and hit the calculate button. Here is how the Power Transmitted using Load Current(Two-Wire Mid-Point Earthed) calculation can be explained with given input values -> 373.612 = 3.1*2*60.26.

FAQ

What is Power Transmitted using Load Current(Two-Wire Mid-Point Earthed)?
The Power Transmitted using Load Current(Two-Wire Mid-point Earthed) formula is defined as proportional to its effective range. The higher the transmit power, the farther a signal can travel, and the more obstructions it can effectively penetrate and is represented as P = I*2*Vm or Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC. Current Overhead DC is defined as the current flowing through the overhead ac supply wire & Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
How to calculate Power Transmitted using Load Current(Two-Wire Mid-Point Earthed)?
The Power Transmitted using Load Current(Two-Wire Mid-point Earthed) formula is defined as proportional to its effective range. The higher the transmit power, the farther a signal can travel, and the more obstructions it can effectively penetrate is calculated using Power Transmitted = Current Overhead DC*2*Maximum Voltage Overhead DC. To calculate Power Transmitted using Load Current(Two-Wire Mid-Point Earthed), you need Current Overhead DC (I) & Maximum Voltage Overhead DC (Vm). With our tool, you need to enter the respective value for Current Overhead DC & Maximum Voltage Overhead DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Transmitted?
In this formula, Power Transmitted uses Current Overhead DC & Maximum Voltage Overhead DC. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Power Transmitted = Maximum Voltage Overhead DC*sqrt(Line Losses*2*Area of Overhead DC Wire/(Resistivity*Length of Wire DC))
  • Power Transmitted = sqrt(Line Losses*Volume of Conductor*(Maximum Voltage Overhead DC^2)/(Resistivity*(Length of Wire DC)^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!