Power Transmitted using Load Current (Single Phase Two Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2))
P = (I*Vm*cos(Φ))/(sqrt(2))
This formula uses 2 Functions, 4 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Current Overhead AC - (Measured in Ampere) - Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Maximum Voltage Overhead AC - (Measured in Volt) - Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
STEP 1: Convert Input(s) to Base Unit
Current Overhead AC: 6.9 Ampere --> 6.9 Ampere No Conversion Required
Maximum Voltage Overhead AC: 62 Volt --> 62 Volt No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = (I*Vm*cos(Φ))/(sqrt(2)) --> (6.9*62*cos(0.5235987755982))/(sqrt(2))
Evaluating ... ...
P = 261.972927990661
STEP 3: Convert Result to Output's Unit
261.972927990661 Watt --> No Conversion Required
FINAL ANSWER
261.972927990661 261.9729 Watt <-- Power Transmitted
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Power and Power Factor Calculators

Power Transmitted using Area of X-Section(Single Phase Two Wire OS)
​ LaTeX ​ Go Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(4*Resistivity*Length of Overhead AC Wire))
Power Factor using Area of X-Section(Single phase Two Wire OS)
​ LaTeX ​ Go Power Factor = sqrt((4*Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(Area of Overhead AC Wire*Line Losses*(Maximum Voltage Overhead AC^2)))
Power Transmitted using Load Current (Single Phase Two Wire OS)
​ LaTeX ​ Go Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2))
Power Factor using Load Current (Single Phase Two Wire OS)
​ LaTeX ​ Go Power Factor = (sqrt(2)*Power Transmitted)/(Maximum Voltage Overhead AC*Current Overhead AC)

Power Transmitted using Load Current (Single Phase Two Wire OS) Formula

​LaTeX ​Go
Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2))
P = (I*Vm*cos(Φ))/(sqrt(2))

What is the value of maximum voltage and volume of conductor material in 1-phase 2-wire system?

The volume of conductor material required in this system is 2/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Power Transmitted using Load Current (Single Phase Two Wire OS)?

Power Transmitted using Load Current (Single Phase Two Wire OS) calculator uses Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2)) to calculate the Power Transmitted, The Power Transmitted using Load Current (single Phase two Wire OS) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to calculate Power Transmitted using Load Current (Single Phase Two Wire OS) using this online calculator? To use this online calculator for Power Transmitted using Load Current (Single Phase Two Wire OS), enter Current Overhead AC (I), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) and hit the calculate button. Here is how the Power Transmitted using Load Current (Single Phase Two Wire OS) calculation can be explained with given input values -> 261.9729 = (6.9*62*cos(0.5235987755982))/(sqrt(2)).

FAQ

What is Power Transmitted using Load Current (Single Phase Two Wire OS)?
The Power Transmitted using Load Current (single Phase two Wire OS) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations and is represented as P = (I*Vm*cos(Φ))/(sqrt(2)) or Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2)). Current Overhead AC is defined as the current flowing through the overhead ac supply wire, Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire & Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
How to calculate Power Transmitted using Load Current (Single Phase Two Wire OS)?
The Power Transmitted using Load Current (single Phase two Wire OS) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations is calculated using Power Transmitted = (Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference))/(sqrt(2)). To calculate Power Transmitted using Load Current (Single Phase Two Wire OS), you need Current Overhead AC (I), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ). With our tool, you need to enter the respective value for Current Overhead AC, Maximum Voltage Overhead AC & Phase Difference and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Transmitted?
In this formula, Power Transmitted uses Current Overhead AC, Maximum Voltage Overhead AC & Phase Difference. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(4*Resistivity*Length of Overhead AC Wire))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!