Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC))
P = sqrt(A*Pline*(Vm^2)/(2*ρ*l))
This formula uses 1 Functions, 6 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Area of underground dc wire - (Measured in Square Meter) - The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Line Losses - (Measured in Watt) - Line Losses is defined as the losses that are produced in the line.
Maximum Voltage - (Measured in Volt) - Maximum Voltage the highest voltage rating for electrical devices.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the measurement or extent of something from end to end.
STEP 1: Convert Input(s) to Base Unit
Area of underground dc wire: 0.32 Square Meter --> 0.32 Square Meter No Conversion Required
Line Losses: 0.6 Watt --> 0.6 Watt No Conversion Required
Maximum Voltage: 60 Volt --> 60 Volt No Conversion Required
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Wire DC: 3.2 Meter --> 3.2 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = sqrt(A*Pline*(Vm^2)/(2*ρ*l)) --> sqrt(0.32*0.6*(60^2)/(2*1.7E-05*3.2))
Evaluating ... ...
P = 2520.50415125042
STEP 3: Convert Result to Output's Unit
2520.50415125042 Watt --> No Conversion Required
FINAL ANSWER
2520.50415125042 2520.504 Watt <-- Power Transmitted
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Power and Resistivity Calculators

Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US)
​ LaTeX ​ Go Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC))
Power Transmitted using Volume of Conductor Material (2-Wire Mid-Point DC US)
​ LaTeX ​ Go Power Transmitted = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/(4*Resistivity*(Length of Wire DC^2)))
Resistivity using Area of X-Section (2-wire Mid-point earthed DC US)
​ LaTeX ​ Go Resistivity = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Length of Wire DC)
Power Transmitted using Load Current (2-Wire Mid-Point DC US)
​ LaTeX ​ Go Power Transmitted = Current underground DC*Maximum Voltage

Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US) Formula

​LaTeX ​Go
Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC))
P = sqrt(A*Pline*(Vm^2)/(2*ρ*l))

What are the different stages of power transmission?

There are three stages of electric power supply; generation, transmission, and distribution. Each of these stages involves distinct production processes, work activities, and hazards. Most electricity is generated at 13,200 to 24,000 volts.

How to Calculate Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US)?

Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US) calculator uses Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC)) to calculate the Power Transmitted, The Power Transmitted using Area of X-Section (2-wire Mid-point earthed DC US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted is denoted by P symbol.

How to calculate Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US) using this online calculator? To use this online calculator for Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US), enter Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Length of Wire DC (l) and hit the calculate button. Here is how the Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US) calculation can be explained with given input values -> 2520.504 = sqrt(0.32*0.6*(60^2)/(2*1.7E-05*3.2)).

FAQ

What is Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US)?
The Power Transmitted using Area of X-Section (2-wire Mid-point earthed DC US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations and is represented as P = sqrt(A*Pline*(Vm^2)/(2*ρ*l)) or Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC)). The Area of underground dc wire is the amount of two-dimensional space taken up by an object, Line Losses is defined as the losses that are produced in the line, Maximum Voltage the highest voltage rating for electrical devices, Resistivity is the measure of how strongly a material opposes the flow of current through them & Length of Wire DC is the measurement or extent of something from end to end.
How to calculate Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US)?
The Power Transmitted using Area of X-Section (2-wire Mid-point earthed DC US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations is calculated using Power Transmitted = sqrt(Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*Length of Wire DC)). To calculate Power Transmitted using Area of X-Section (2-Wire Mid-Point Earthed DC US), you need Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Length of Wire DC (l). With our tool, you need to enter the respective value for Area of underground dc wire, Line Losses, Maximum Voltage, Resistivity & Length of Wire DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Transmitted?
In this formula, Power Transmitted uses Area of underground dc wire, Line Losses, Maximum Voltage, Resistivity & Length of Wire DC. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Power Transmitted = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/(4*Resistivity*(Length of Wire DC^2)))
  • Power Transmitted = Current underground DC*Maximum Voltage
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!