Power transmitted by synchronous belt Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power transmitted by belt = Standard Capacity of Belt/Service Correction Factor
Pt = Ps/Cs
This formula uses 3 Variables
Variables Used
Power transmitted by belt - (Measured in Watt) - Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Standard Capacity of Belt - (Measured in Watt) - Standard capacity of belt is the power capacity of the belt from which the power needs to be transmitted to the other end.
Service Correction Factor - Service correction factor or simply service factor is defined as the ratio of maximum torque to the rated torque.
STEP 1: Convert Input(s) to Base Unit
Standard Capacity of Belt: 8.38 Kilowatt --> 8380 Watt (Check conversion ​here)
Service Correction Factor: 1.3 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pt = Ps/Cs --> 8380/1.3
Evaluating ... ...
Pt = 6446.15384615385
STEP 3: Convert Result to Output's Unit
6446.15384615385 Watt -->6.44615384615385 Kilowatt (Check conversion ​here)
FINAL ANSWER
6.44615384615385 6.446154 Kilowatt <-- Power transmitted by belt
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Indian Institute of Technology (IIT (ISM) ), Dhanbad, Jharkhand
Aditya Prakash Gautam has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Synchronous Belt Drives Calculators

Transmission Ratio of Synchronous belt drive given no. of teeth in smaller and larger pulley
​ LaTeX ​ Go Transmission Ratio of Belt Drive = Number of teeth on larger pulley/Number of teeth on smaller pulley
Transmission Ratio of Synchronous belt drive given Speed of smaller and larger pulley
​ LaTeX ​ Go Transmission Ratio of Belt Drive = Speed of Smaller Pulley/Speed of Larger Pulley
Speed of smaller pulley given Transmission ratio of Synchronous belt drive
​ LaTeX ​ Go Speed of Smaller Pulley = Speed of Larger Pulley*Transmission Ratio of Belt Drive
Speed of larger pulley given Transmission ratio of Synchronous belt drive
​ LaTeX ​ Go Speed of Larger Pulley = Speed of Smaller Pulley/Transmission Ratio of Belt Drive

Power transmitted by synchronous belt Formula

​LaTeX ​Go
Power transmitted by belt = Standard Capacity of Belt/Service Correction Factor
Pt = Ps/Cs

What are the factors affecting power transmission by belt drive ?

Since belt drive is a friction drive, so power transmission capacity primarily relies on the frictional characteristics of the mating surfaces. Higher the coefficient of friction between the belt and pulley, higher will be the power transmission capacity; however, heat generation and wear will also be more. Synchronous belt drive is the highly efficient system of power transmission as it has molded belt teeth meshing with sprocket teeth. Synchronous belts wrap around the sprocket by means of flexion and not by rotation of articulated parts as do chains. This eliminates one of the causes of wear and noise. Synchronous belt does not allow slippage as there are drives where synchronicity is a necessity and any slippage can cause damage.

How to Calculate Power transmitted by synchronous belt?

Power transmitted by synchronous belt calculator uses Power transmitted by belt = Standard Capacity of Belt/Service Correction Factor to calculate the Power transmitted by belt, The Power transmitted by synchronous belt formula is defined as the standard capacity of the belt divided by the service correction factor. Power transmitted by belt is denoted by Pt symbol.

How to calculate Power transmitted by synchronous belt using this online calculator? To use this online calculator for Power transmitted by synchronous belt, enter Standard Capacity of Belt (Ps) & Service Correction Factor (Cs) and hit the calculate button. Here is how the Power transmitted by synchronous belt calculation can be explained with given input values -> 0.006446 = 8380/1.3.

FAQ

What is Power transmitted by synchronous belt?
The Power transmitted by synchronous belt formula is defined as the standard capacity of the belt divided by the service correction factor and is represented as Pt = Ps/Cs or Power transmitted by belt = Standard Capacity of Belt/Service Correction Factor. Standard capacity of belt is the power capacity of the belt from which the power needs to be transmitted to the other end & Service correction factor or simply service factor is defined as the ratio of maximum torque to the rated torque.
How to calculate Power transmitted by synchronous belt?
The Power transmitted by synchronous belt formula is defined as the standard capacity of the belt divided by the service correction factor is calculated using Power transmitted by belt = Standard Capacity of Belt/Service Correction Factor. To calculate Power transmitted by synchronous belt, you need Standard Capacity of Belt (Ps) & Service Correction Factor (Cs). With our tool, you need to enter the respective value for Standard Capacity of Belt & Service Correction Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!