Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Factor = sqrt((0.625)*Constant Overhead AC/Volume of Conductor)
PF = sqrt((0.625)*K/V)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Power Factor - The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Constant Overhead AC - Constant Overhead AC is defined as the constant of line of a Overhead supply system.
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
STEP 1: Convert Input(s) to Base Unit
Constant Overhead AC: 0.89 --> No Conversion Required
Volume of Conductor: 26 Cubic Meter --> 26 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
PF = sqrt((0.625)*K/V) --> sqrt((0.625)*0.89/26)
Evaluating ... ...
PF = 0.14626766822928
STEP 3: Convert Result to Output's Unit
0.14626766822928 --> No Conversion Required
FINAL ANSWER
0.14626766822928 0.146268 <-- Power Factor
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Power and Power Factor Calculators

Power Transmitted using Area of X-Section(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Power Transmitted = sqrt((Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/(Resistivity*Length of Overhead AC Wire))
Power Transmitted using Line Losses (Single-Phase Three-Wire OS)
​ LaTeX ​ Go Power Transmitted = sqrt(Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/(Resistivity*Length of Overhead AC Wire))
Power Factor using Area of X-Section(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Power Factor = sqrt((Power Transmitted^2)*Resistivity*Length of Overhead AC Wire/(Area of Overhead AC Wire*Line Losses*(Maximum Voltage Overhead AC^2)))
Power Transmitted using Load Current (Single-Phase Three-Wire OS)
​ LaTeX ​ Go Power Transmitted = Current Overhead AC*Maximum Voltage Overhead AC*cos(Phase Difference)*sqrt(2)

Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS) Formula

​LaTeX ​Go
Power Factor = sqrt((0.625)*Constant Overhead AC/Volume of Conductor)
PF = sqrt((0.625)*K/V)

What is the value of maximum voltage and volume of conductor material in 1-phase 3-wire system?

The volume of conductor material required in this system is 0.625/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS)?

Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS) calculator uses Power Factor = sqrt((0.625)*Constant Overhead AC/Volume of Conductor) to calculate the Power Factor, The Power Factor using Volume of Conductor Material (single-phase three-wire OS) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit. Power Factor is denoted by PF symbol.

How to calculate Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS) using this online calculator? To use this online calculator for Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS), enter Constant Overhead AC (K) & Volume of Conductor (V) and hit the calculate button. Here is how the Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS) calculation can be explained with given input values -> 0.146268 = sqrt((0.625)*0.89/26).

FAQ

What is Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS)?
The Power Factor using Volume of Conductor Material (single-phase three-wire OS) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit and is represented as PF = sqrt((0.625)*K/V) or Power Factor = sqrt((0.625)*Constant Overhead AC/Volume of Conductor). Constant Overhead AC is defined as the constant of line of a Overhead supply system & Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
How to calculate Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS)?
The Power Factor using Volume of Conductor Material (single-phase three-wire OS) formula is defined as the cosine of the angle between the voltage phasor and current phasor in an AC circuit is calculated using Power Factor = sqrt((0.625)*Constant Overhead AC/Volume of Conductor). To calculate Power Factor using Volume of Conductor Material (Single-Phase Three-Wire OS), you need Constant Overhead AC (K) & Volume of Conductor (V). With our tool, you need to enter the respective value for Constant Overhead AC & Volume of Conductor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Factor?
In this formula, Power Factor uses Constant Overhead AC & Volume of Conductor. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Power Factor = sqrt((Power Transmitted^2)*Resistivity*Length of Overhead AC Wire/(Area of Overhead AC Wire*Line Losses*(Maximum Voltage Overhead AC^2)))
  • Power Factor = Power Transmitted/(sqrt(Phase Difference)*Maximum Voltage Overhead AC*Current Overhead AC)
  • Power Factor = (Power Transmitted/Maximum Voltage Overhead AC)*sqrt(Resistivity*Length of Overhead AC Wire)/(Line Losses*Area of Overhead AC Wire)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!