Power Factor of Synchronous Motor using 3 Phase Input Power Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Factor = Three Phase Input Power/(sqrt(3)*Load Voltage*Load Current)
CosΦ = Pin(3Φ)/(sqrt(3)*VL*IL)
This formula uses 1 Functions, 4 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Power Factor - The power factor of an AC electrical power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit.
Three Phase Input Power - (Measured in Watt) - Three Phase Input Power is defined as the three phase power supplied an synchronous motor.
Load Voltage - (Measured in Volt) - The Load Voltage is defined as the voltage between two terminals of load.
Load Current - (Measured in Ampere) - Load current is defined as the magnitude of the current drawn from an electric circuit by the load (electrical machine) connected across it.
STEP 1: Convert Input(s) to Base Unit
Three Phase Input Power: 1584 Watt --> 1584 Watt No Conversion Required
Load Voltage: 192 Volt --> 192 Volt No Conversion Required
Load Current: 5.5 Ampere --> 5.5 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
CosΦ = Pin(3Φ)/(sqrt(3)*VL*IL) --> 1584/(sqrt(3)*192*5.5)
Evaluating ... ...
CosΦ = 0.866025403784439
STEP 3: Convert Result to Output's Unit
0.866025403784439 --> No Conversion Required
FINAL ANSWER
0.866025403784439 0.866025 <-- Power Factor
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

Power Factor and Phase Angle Calculators

Phase Angle between Voltage and Armature Current given 3 Phase Mechanical Power
​ Go Phase Difference = acos((Mechanical Power+3*Armature Current^2*Armature Resistance)/(sqrt(3)*Load Current*Load Voltage))
Power Factor of Synchronous Motor given 3 Phase Mechanical Power
​ Go Power Factor = (Three Phase Mechanical Power+3*Armature Current^2*Armature Resistance)/(sqrt(3)*Load Voltage*Load Current)
Phase Angle between Load Voltage and Current given 3 Phase Input Power
​ Go Phase Difference = acos(Three Phase Input Power/(sqrt(3)*Voltage*Load Current))
Phase Angle between Voltage and Armature Current given Input Power
​ Go Phase Difference = acos(Input Power/(Voltage*Armature Current))

Synchronous Motor Circuit Calculators

Load Current of Synchronous Motor given 3 Phase Mechanical Power
​ Go Load Current = (Three Phase Mechanical Power+3*Armature Current^2*Armature Resistance)/(sqrt(3)*Load Voltage*cos(Phase Difference))
Armature Current of Synchronous Motor given 3 Phase Mechanical Power
​ Go Armature Current = sqrt((Three Phase Input Power-Three Phase Mechanical Power)/(3*Armature Resistance))
Armature Current of Synchronous Motor given Mechanical Power
​ Go Armature Current = sqrt((Input Power-Mechanical Power)/Armature Resistance)
Armature Current of Synchronous Motor given Input Power
​ Go Armature Current = Input Power/(cos(Phase Difference)*Voltage)

Power Factor of Synchronous Motor using 3 Phase Input Power Formula

Power Factor = Three Phase Input Power/(sqrt(3)*Load Voltage*Load Current)
CosΦ = Pin(3Φ)/(sqrt(3)*VL*IL)

What is the power developed by a motor?

In an electric motor, the mechanical power is defined as the speed times the torque. Mechanical power is typically defined as kilowatts (kW) or horsepower (hp) with one watt equaling one joule per second or one Newton-Meter per second.

How to Calculate Power Factor of Synchronous Motor using 3 Phase Input Power?

Power Factor of Synchronous Motor using 3 Phase Input Power calculator uses Power Factor = Three Phase Input Power/(sqrt(3)*Load Voltage*Load Current) to calculate the Power Factor, The Power Factor of Synchronous Motor using 3 phase Input Power formula is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Power Factor is denoted by CosΦ symbol.

How to calculate Power Factor of Synchronous Motor using 3 Phase Input Power using this online calculator? To use this online calculator for Power Factor of Synchronous Motor using 3 Phase Input Power, enter Three Phase Input Power (Pin(3Φ)), Load Voltage (VL) & Load Current (IL) and hit the calculate button. Here is how the Power Factor of Synchronous Motor using 3 Phase Input Power calculation can be explained with given input values -> 0.866025 = 1584/(sqrt(3)*192*5.5).

FAQ

What is Power Factor of Synchronous Motor using 3 Phase Input Power?
The Power Factor of Synchronous Motor using 3 phase Input Power formula is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit and is represented as CosΦ = Pin(3Φ)/(sqrt(3)*VL*IL) or Power Factor = Three Phase Input Power/(sqrt(3)*Load Voltage*Load Current). Three Phase Input Power is defined as the three phase power supplied an synchronous motor, The Load Voltage is defined as the voltage between two terminals of load & Load current is defined as the magnitude of the current drawn from an electric circuit by the load (electrical machine) connected across it.
How to calculate Power Factor of Synchronous Motor using 3 Phase Input Power?
The Power Factor of Synchronous Motor using 3 phase Input Power formula is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit is calculated using Power Factor = Three Phase Input Power/(sqrt(3)*Load Voltage*Load Current). To calculate Power Factor of Synchronous Motor using 3 Phase Input Power, you need Three Phase Input Power (Pin(3Φ)), Load Voltage (VL) & Load Current (IL). With our tool, you need to enter the respective value for Three Phase Input Power, Load Voltage & Load Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Factor?
In this formula, Power Factor uses Three Phase Input Power, Load Voltage & Load Current. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Power Factor = (Three Phase Mechanical Power+3*Armature Current^2*Armature Resistance)/(sqrt(3)*Load Voltage*Load Current)
  • Power Factor = Input Power/(Voltage*Armature Current)
  • Power Factor = Input Power/(Voltage*Armature Current)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!