Positive Sequence Voltage for Delta Connected Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3
V1 = (Zd*I1)/3
This formula uses 3 Variables
Variables Used
Positive Sequence Voltage - (Measured in Volt) - Positive Sequence Voltage is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Delta Impedance - (Measured in Ohm) - Delta Impedance is defined as the impedance of delta connected network.
Positive Sequence Current - (Measured in Ampere) - Positive Sequence Current is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
STEP 1: Convert Input(s) to Base Unit
Delta Impedance: 9 Ohm --> 9 Ohm No Conversion Required
Positive Sequence Current: 2 Ampere --> 2 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V1 = (Zd*I1)/3 --> (9*2)/3
Evaluating ... ...
V1 = 6
STEP 3: Convert Result to Output's Unit
6 Volt --> No Conversion Required
FINAL ANSWER
6 Volt <-- Positive Sequence Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Sequence Current and Voltage Calculators

Zero Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Zero Sequence Voltage = (Star Impedance+3*Fault Impedance)*Zero Sequence Current
Positive Sequence Voltage for Delta Connected Load
​ LaTeX ​ Go Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3
Negative Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Negative Sequence Voltage = Negative Sequence Current*Star Impedance
Positive Sequence Voltage for Star Connected Load
​ LaTeX ​ Go Positive Sequence Voltage = Star Impedance*Positive Sequence Current

Positive Sequence Voltage for Delta Connected Load Formula

​LaTeX ​Go
Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3
V1 = (Zd*I1)/3

What are the Sequence Components?

The positive sequence consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. The negative sequence consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Zero sequence consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.

How to Calculate Positive Sequence Voltage for Delta Connected Load?

Positive Sequence Voltage for Delta Connected Load calculator uses Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3 to calculate the Positive Sequence Voltage, The Positive Sequence Voltage for Delta Connected Load formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Voltage is denoted by V1 symbol.

How to calculate Positive Sequence Voltage for Delta Connected Load using this online calculator? To use this online calculator for Positive Sequence Voltage for Delta Connected Load, enter Delta Impedance (Zd) & Positive Sequence Current (I1) and hit the calculate button. Here is how the Positive Sequence Voltage for Delta Connected Load calculation can be explained with given input values -> 6.003 = (9*2)/3.

FAQ

What is Positive Sequence Voltage for Delta Connected Load?
The Positive Sequence Voltage for Delta Connected Load formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation and is represented as V1 = (Zd*I1)/3 or Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3. Delta Impedance is defined as the impedance of delta connected network & Positive Sequence Current is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
How to calculate Positive Sequence Voltage for Delta Connected Load?
The Positive Sequence Voltage for Delta Connected Load formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation is calculated using Positive Sequence Voltage = (Delta Impedance*Positive Sequence Current)/3. To calculate Positive Sequence Voltage for Delta Connected Load, you need Delta Impedance (Zd) & Positive Sequence Current (I1). With our tool, you need to enter the respective value for Delta Impedance & Positive Sequence Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Positive Sequence Voltage?
In this formula, Positive Sequence Voltage uses Delta Impedance & Positive Sequence Current. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Positive Sequence Voltage = Star Impedance*Positive Sequence Current