Positive Sequence Potential Difference (Two Conductor Open) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO
Vaa'1(tco) = ((-1)*Vaa'2(tco))-Vaa'0(tco)
This formula uses 3 Variables
Variables Used
Positive Sequence Potential Difference in TCO - (Measured in Volt) - Positive Sequence Potential Difference in TCO is defined as consisting of balanced 3-phase potential differences phasor which are exactly at 120 degrees in ABC rotation.
Negative Sequence Potential Difference in TCO - (Measured in Volt) - Negative Sequence Potential Difference in TCO in open conductor fault is defined as consisting of balanced three-phase potential differences phasors which are exactly at 120 degree in ACB rotation.
Zero Sequence Potential Difference in TCO - (Measured in Volt) - Zero Sequence Potential Difference in TCO is defined as consisting of balanced three-phase potential differences, phasors of which all have the same phase angles.
STEP 1: Convert Input(s) to Base Unit
Negative Sequence Potential Difference in TCO: -7.11 Volt --> -7.11 Volt No Conversion Required
Zero Sequence Potential Difference in TCO: 3.66 Volt --> 3.66 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vaa'1(tco) = ((-1)*Vaa'2(tco))-Vaa'0(tco) --> ((-1)*(-7.11))-3.66
Evaluating ... ...
Vaa'1(tco) = 3.45
STEP 3: Convert Result to Output's Unit
3.45 Volt --> No Conversion Required
FINAL ANSWER
3.45 Volt <-- Positive Sequence Potential Difference in TCO
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Positive Sequence Calculators

Positive Sequence Impedance using A-Phase EMF (Two Conductor Open)
​ LaTeX ​ Go Positive Sequence Impedance in TCO = (A Phase EMF in TCO/Positive Sequence Current in TCO)-Zero Sequence Impedance in TCO-Negative Sequence Impedance in TCO
Positive Sequence Current using A-Phase EMF (Two Conductor Open)
​ LaTeX ​ Go Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
Positive Sequence Potential Difference (Two Conductor Open)
​ LaTeX ​ Go Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO
Positive Sequence Current (Two Conductor Open)
​ LaTeX ​ Go Positive Sequence Current in TCO = A-Phase Current in TCO/3

Positive Sequence Potential Difference (Two Conductor Open) Formula

​LaTeX ​Go
Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO
Vaa'1(tco) = ((-1)*Vaa'2(tco))-Vaa'0(tco)

What is two open conductor fault?

When two phases of a balanced three-phase line open it creates an unbalance in the system and results in the flow of unbalanced currents. Such conditions occur in the system when one or two conductors of a transmission line are broken due to storms or if fuses, isolators, or circuit breakers operate only on one or two phases leaving others connected.

How to Calculate Positive Sequence Potential Difference (Two Conductor Open)?

Positive Sequence Potential Difference (Two Conductor Open) calculator uses Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO to calculate the Positive Sequence Potential Difference in TCO, The Positive Sequence Potential Difference (Two conductor open) formula is defined as consists of balanced three-phase potential differences phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Potential Difference in TCO is denoted by Vaa'1(tco) symbol.

How to calculate Positive Sequence Potential Difference (Two Conductor Open) using this online calculator? To use this online calculator for Positive Sequence Potential Difference (Two Conductor Open), enter Negative Sequence Potential Difference in TCO (Vaa'2(tco)) & Zero Sequence Potential Difference in TCO (Vaa'0(tco)) and hit the calculate button. Here is how the Positive Sequence Potential Difference (Two Conductor Open) calculation can be explained with given input values -> 4.05 = ((-1)*(-7.11))-3.66.

FAQ

What is Positive Sequence Potential Difference (Two Conductor Open)?
The Positive Sequence Potential Difference (Two conductor open) formula is defined as consists of balanced three-phase potential differences phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation and is represented as Vaa'1(tco) = ((-1)*Vaa'2(tco))-Vaa'0(tco) or Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO. Negative Sequence Potential Difference in TCO in open conductor fault is defined as consisting of balanced three-phase potential differences phasors which are exactly at 120 degree in ACB rotation & Zero Sequence Potential Difference in TCO is defined as consisting of balanced three-phase potential differences, phasors of which all have the same phase angles.
How to calculate Positive Sequence Potential Difference (Two Conductor Open)?
The Positive Sequence Potential Difference (Two conductor open) formula is defined as consists of balanced three-phase potential differences phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation is calculated using Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO. To calculate Positive Sequence Potential Difference (Two Conductor Open), you need Negative Sequence Potential Difference in TCO (Vaa'2(tco)) & Zero Sequence Potential Difference in TCO (Vaa'0(tco)). With our tool, you need to enter the respective value for Negative Sequence Potential Difference in TCO & Zero Sequence Potential Difference in TCO and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!