Population in Thousands given Peak Sewage Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Population in Thousands = ((18*Average Daily Flow-4*Peak Sewage Flow)/(Peak Sewage Flow-Average Daily Flow))^2
P = ((18*Qav-4*Qmax)/(Qmax-Qav))^2
This formula uses 3 Variables
Variables Used
Population in Thousands - Population in Thousands refers to a demographic representation where the reported number corresponds to actual population multiplied by a factor of one thousand for ease of presentation and analysis.
Average Daily Flow - (Measured in Cubic Meter per Second) - Average Daily Flow (ADF) is a measure of the average amount of water passing a point in a river, stream, or through a water treatment system over the course of a day.
Peak Sewage Flow - (Measured in Cubic Meter per Second) - Peak Sewage Flow refers to the maximum rate at which sewage is discharged from a community or a facility over a short period, typically measured in gallons per minute (GPM) or liters per second (L/s).
STEP 1: Convert Input(s) to Base Unit
Average Daily Flow: 6 Cubic Meter per Second --> 6 Cubic Meter per Second No Conversion Required
Peak Sewage Flow: 11.17 Cubic Meter per Second --> 11.17 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = ((18*Qav-4*Qmax)/(Qmax-Qav))^2 --> ((18*6-4*11.17)/(11.17-6))^2
Evaluating ... ...
P = 150.003269868943
STEP 3: Convert Result to Output's Unit
150.003269868943 --> No Conversion Required
FINAL ANSWER
150.003269868943 150.0033 <-- Population in Thousands
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Estimating the Design Sewage Discharge Calculators

Maximum Hourly Flow given Maximum Daily Flow for Areas of Moderate Sizes
​ LaTeX ​ Go Maximum Hourly Flow = (1.5*Maximum Daily Flow)
Maximum Daily Flow given Maximum Hourly Flow
​ LaTeX ​ Go Maximum Daily Flow = Maximum Hourly Flow/1.5
Average Daily Flow given Maximum Daily Flow for Areas of Moderate Sizes
​ LaTeX ​ Go Average Daily Flow = (Maximum Daily Flow/2)
Maximum Daily Flow for Areas of Moderate Sizes
​ LaTeX ​ Go Maximum Daily Flow = (2*Average Daily Flow)

Population in Thousands given Peak Sewage Flow Formula

​LaTeX ​Go
Population in Thousands = ((18*Average Daily Flow-4*Peak Sewage Flow)/(Peak Sewage Flow-Average Daily Flow))^2
P = ((18*Qav-4*Qmax)/(Qmax-Qav))^2

What is Average Daily Flow ?

Average Daily Flow refers to the average amount of wastewater that flows through a sewer system each day. It is typically measured in units such as gallons per day (GPD) or cubic meters per day (m³/d). Calculating the ADF is crucial for designing and managing wastewater treatment facilities, ensuring they can handle the expected load without overflow or inefficiency.

How to Calculate Population in Thousands given Peak Sewage Flow?

Population in Thousands given Peak Sewage Flow calculator uses Population in Thousands = ((18*Average Daily Flow-4*Peak Sewage Flow)/(Peak Sewage Flow-Average Daily Flow))^2 to calculate the Population in Thousands, The Population in Thousands given Peak Sewage Flow refers to a demographic representation where the reported number corresponds to actual population multiplied by a factor of one thousand for ease of presentation and analysis. Population in Thousands is denoted by P symbol.

How to calculate Population in Thousands given Peak Sewage Flow using this online calculator? To use this online calculator for Population in Thousands given Peak Sewage Flow, enter Average Daily Flow (Qav) & Peak Sewage Flow (Qmax) and hit the calculate button. Here is how the Population in Thousands given Peak Sewage Flow calculation can be explained with given input values -> 150.0033 = ((18*6-4*11.17)/(11.17-6))^2.

FAQ

What is Population in Thousands given Peak Sewage Flow?
The Population in Thousands given Peak Sewage Flow refers to a demographic representation where the reported number corresponds to actual population multiplied by a factor of one thousand for ease of presentation and analysis and is represented as P = ((18*Qav-4*Qmax)/(Qmax-Qav))^2 or Population in Thousands = ((18*Average Daily Flow-4*Peak Sewage Flow)/(Peak Sewage Flow-Average Daily Flow))^2. Average Daily Flow (ADF) is a measure of the average amount of water passing a point in a river, stream, or through a water treatment system over the course of a day & Peak Sewage Flow refers to the maximum rate at which sewage is discharged from a community or a facility over a short period, typically measured in gallons per minute (GPM) or liters per second (L/s).
How to calculate Population in Thousands given Peak Sewage Flow?
The Population in Thousands given Peak Sewage Flow refers to a demographic representation where the reported number corresponds to actual population multiplied by a factor of one thousand for ease of presentation and analysis is calculated using Population in Thousands = ((18*Average Daily Flow-4*Peak Sewage Flow)/(Peak Sewage Flow-Average Daily Flow))^2. To calculate Population in Thousands given Peak Sewage Flow, you need Average Daily Flow (Qav) & Peak Sewage Flow (Qmax). With our tool, you need to enter the respective value for Average Daily Flow & Peak Sewage Flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!