Phase Detector Average Voltage Solution

STEP 0: Pre-Calculation Summary
Formula Used
XOR Phase Detector Average Voltage = XOR Phase Detector Current/XOR Phase Detector Phase
Kpd = ipd/Φerr
This formula uses 3 Variables
Variables Used
XOR Phase Detector Average Voltage - (Measured in Volt) - XOR Phase Detector Average Voltage is the averaging of all the instantaneous values along the time axis with time being one full period, (T).
XOR Phase Detector Current - (Measured in Ampere) - XOR Phase Detector Current is defined as an electric current(which is a stream of charged particles, such as electrons or ions)moving through an electrical conductor or space.
XOR Phase Detector Phase - (Measured in Radian) - XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs.
STEP 1: Convert Input(s) to Base Unit
XOR Phase Detector Current: 499.93 Milliampere --> 0.49993 Ampere (Check conversion ​here)
XOR Phase Detector Phase: 9.3 Degree --> 0.162315620435442 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Kpd = ipderr --> 0.49993/0.162315620435442
Evaluating ... ...
Kpd = 3.07998699483663
STEP 3: Convert Result to Output's Unit
3.07998699483663 Volt --> No Conversion Required
FINAL ANSWER
3.07998699483663 3.079987 Volt <-- XOR Phase Detector Average Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

CMOS Time Characteristics Calculators

Aperture Time for Falling Input
​ LaTeX ​ Go Aperture Time for Falling Input = Setup Time at Low Logic+Hold Time at High Logic
Setup Time at Low Logic
​ LaTeX ​ Go Setup Time at Low Logic = Aperture Time for Falling Input-Hold Time at High Logic
Aperture Time for Rising Input
​ LaTeX ​ Go Aperture Time for Rising Input = Setup Time at High Logic+Hold Time at Low Logic
Setup Time at High Logic
​ LaTeX ​ Go Setup Time at High Logic = Aperture Time for Rising Input-Hold Time at Low Logic

Phase Detector Average Voltage Formula

​LaTeX ​Go
XOR Phase Detector Average Voltage = XOR Phase Detector Current/XOR Phase Detector Phase
Kpd = ipd/Φerr

What is Subthreshold conduction ?

Subthreshold conduction or subthreshold leakage or subthreshold drain current is the current between the source and drain of a MOSFET when the transistor is in subthreshold region, or weak-inversion region, that is, for gate-to-source voltages below the threshold voltage.

How to Calculate Phase Detector Average Voltage?

Phase Detector Average Voltage calculator uses XOR Phase Detector Average Voltage = XOR Phase Detector Current/XOR Phase Detector Phase to calculate the XOR Phase Detector Average Voltage, Phase Detector Average Voltage refers to the average value of the output voltage produced by the phase detector when the input signals are compared. XOR Phase Detector Average Voltage is denoted by Kpd symbol.

How to calculate Phase Detector Average Voltage using this online calculator? To use this online calculator for Phase Detector Average Voltage, enter XOR Phase Detector Current (ipd) & XOR Phase Detector Phase err) and hit the calculate button. Here is how the Phase Detector Average Voltage calculation can be explained with given input values -> 3.137468 = 0.49993/0.162315620435442.

FAQ

What is Phase Detector Average Voltage?
Phase Detector Average Voltage refers to the average value of the output voltage produced by the phase detector when the input signals are compared and is represented as Kpd = ipderr or XOR Phase Detector Average Voltage = XOR Phase Detector Current/XOR Phase Detector Phase. XOR Phase Detector Current is defined as an electric current(which is a stream of charged particles, such as electrons or ions)moving through an electrical conductor or space & XOR Phase Detector Phase where phase detector is a frequency mixer, an analog multiplier that generates a voltage signal which represents the difference in phase between two signal inputs.
How to calculate Phase Detector Average Voltage?
Phase Detector Average Voltage refers to the average value of the output voltage produced by the phase detector when the input signals are compared is calculated using XOR Phase Detector Average Voltage = XOR Phase Detector Current/XOR Phase Detector Phase. To calculate Phase Detector Average Voltage, you need XOR Phase Detector Current (ipd) & XOR Phase Detector Phase err). With our tool, you need to enter the respective value for XOR Phase Detector Current & XOR Phase Detector Phase and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!