Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling Solution

STEP 0: Pre-Calculation Summary
Formula Used
Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling)
Pa = P/(Db*lb)
This formula uses 4 Variables
Variables Used
Intensity of Pressure Between Flange - (Measured in Pascal) - Intensity of Pressure Between Flange is defined as the maximum limit of compressive stress that the bush and the flange can resist.
Force on Each Rubber Bush or Pin of Coupling - (Measured in Newton) - Force on Each Rubber Bush or Pin of Coupling is the amount of force that is acting onto an individual bush or pin of the coupling.
Outer Diameter of Bush For Coupling - (Measured in Meter) - Outer Diameter of Bush For Coupling is defined as the diameter of the outside diameter of the bush used inside the coupling.
Effective Length of Bush of Coupling - (Measured in Meter) - Effective Length of Bush of Coupling is the length of the bush of the coupling in contact with the flange.
STEP 1: Convert Input(s) to Base Unit
Force on Each Rubber Bush or Pin of Coupling: 1150 Newton --> 1150 Newton No Conversion Required
Outer Diameter of Bush For Coupling: 35 Millimeter --> 0.035 Meter (Check conversion ​here)
Effective Length of Bush of Coupling: 33.5 Millimeter --> 0.0335 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pa = P/(Db*lb) --> 1150/(0.035*0.0335)
Evaluating ... ...
Pa = 980810.234541578
STEP 3: Convert Result to Output's Unit
980810.234541578 Pascal -->0.980810234541578 Newton per Square Millimeter (Check conversion ​here)
FINAL ANSWER
0.980810234541578 0.98081 Newton per Square Millimeter <-- Intensity of Pressure Between Flange
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has created this Calculator and 600+ more calculators!
Verifier Image
Verified by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has verified this Calculator and 200+ more calculators!

Stress Analysis Calculators

Permissible Intensity of Pressure between Flange and Rubber Bush of Coupling given Torque
​ LaTeX ​ Go Intensity of Pressure Between Flange = 2*Torque Transmitted By Coupling/(Outer Diameter of Bush For Coupling*Number of Pins in Coupling*Pitch Circle Diameter of Pins of Coupling*Effective Length of Bush of Coupling)
Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling
​ LaTeX ​ Go Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling)
Force Acting on Each Pin or Bush of Coupling
​ LaTeX ​ Go Force on Each Rubber Bush or Pin of Coupling = Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling*Intensity of Pressure Between Flange
Force Acting on Each Pin or Bush of Coupling given Troque Transmitted
​ LaTeX ​ Go Force on Each Rubber Bush or Pin of Coupling = (2*Torque Transmitted By Coupling)/(Number of Pins in Coupling*Pitch Circle Diameter of Pins of Coupling)

Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling Formula

​LaTeX ​Go
Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling)
Pa = P/(Db*lb)

What is coupling?

A coupling can be defined as a mechanical device that permanently joins two rotating shafts to each other.

How to Calculate Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling?

Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling calculator uses Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling) to calculate the Intensity of Pressure Between Flange, Permissible Intensity of Pressure between Flange and Rubber bush in Bushed Pin Coupling is defined as the limiting value or the allowable value of pressure in between the Flange and Rubber bush in Bushed Pin Coupling. Intensity of Pressure Between Flange is denoted by Pa symbol.

How to calculate Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling using this online calculator? To use this online calculator for Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling, enter Force on Each Rubber Bush or Pin of Coupling (P), Outer Diameter of Bush For Coupling (Db) & Effective Length of Bush of Coupling (lb) and hit the calculate button. Here is how the Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling calculation can be explained with given input values -> 9.8E-7 = 1150/(0.035*0.0335).

FAQ

What is Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling?
Permissible Intensity of Pressure between Flange and Rubber bush in Bushed Pin Coupling is defined as the limiting value or the allowable value of pressure in between the Flange and Rubber bush in Bushed Pin Coupling and is represented as Pa = P/(Db*lb) or Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling). Force on Each Rubber Bush or Pin of Coupling is the amount of force that is acting onto an individual bush or pin of the coupling, Outer Diameter of Bush For Coupling is defined as the diameter of the outside diameter of the bush used inside the coupling & Effective Length of Bush of Coupling is the length of the bush of the coupling in contact with the flange.
How to calculate Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling?
Permissible Intensity of Pressure between Flange and Rubber bush in Bushed Pin Coupling is defined as the limiting value or the allowable value of pressure in between the Flange and Rubber bush in Bushed Pin Coupling is calculated using Intensity of Pressure Between Flange = Force on Each Rubber Bush or Pin of Coupling/(Outer Diameter of Bush For Coupling*Effective Length of Bush of Coupling). To calculate Permissible Intensity of Pressure between Flange and Rubber Bush in Bushed Pin Coupling, you need Force on Each Rubber Bush or Pin of Coupling (P), Outer Diameter of Bush For Coupling (Db) & Effective Length of Bush of Coupling (lb). With our tool, you need to enter the respective value for Force on Each Rubber Bush or Pin of Coupling, Outer Diameter of Bush For Coupling & Effective Length of Bush of Coupling and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Intensity of Pressure Between Flange?
In this formula, Intensity of Pressure Between Flange uses Force on Each Rubber Bush or Pin of Coupling, Outer Diameter of Bush For Coupling & Effective Length of Bush of Coupling. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Intensity of Pressure Between Flange = 2*Torque Transmitted By Coupling/(Outer Diameter of Bush For Coupling*Number of Pins in Coupling*Pitch Circle Diameter of Pins of Coupling*Effective Length of Bush of Coupling)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!