Permeability Number or Standard Specimen Solution

STEP 0: Pre-Calculation Summary
Formula Used
Permeability Number = 501.28/(Pressure in Casting*Time)
PN = 501.28/(pc*tp)
This formula uses 3 Variables
Variables Used
Permeability Number - (Measured in Henry per Meter) - Permeability Number is the rate of flow of air passing through a standard specimen under a standard pressure.
Pressure in Casting - (Measured in Pascal) - Pressure in Casting is the force applied to the molten metal during the casting process, which can affect the flow, filling, and solidification of the material.
Time - (Measured in Second) - Time is various stages and durations throughout the casting process.
STEP 1: Convert Input(s) to Base Unit
Pressure in Casting: 3.9 Kilogram-Force per Square Meter --> 38.2459349999973 Pascal (Check conversion ​here)
Time: 3 Second --> 3 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
PN = 501.28/(pc*tp) --> 501.28/(38.2459349999973*3)
Evaluating ... ...
PN = 4.36891746360352
STEP 3: Convert Result to Output's Unit
4.36891746360352 Henry per Meter --> No Conversion Required
FINAL ANSWER
4.36891746360352 4.368917 Henry per Meter <-- Permeability Number
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Verifier Image
Verified by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has verified this Calculator and 400+ more calculators!

Permeability Number Calculators

Cross-Sectional Area of Specimen
​ LaTeX ​ Go Cross-Sectional Area of Specimen = (Volume of Air Flow Through Specimen*Specimen Height)/(Permeability Number*Air Pressure on Wall*Time)
Air Pressure during Testing
​ LaTeX ​ Go Air Pressure on Wall = (Volume of Air Flow Through Specimen*Specimen Height)/(Permeability Number*Cross-Sectional Area of Specimen*Time)
Time Taken during Testing
​ LaTeX ​ Go Time = (Volume of Air Flow Through Specimen*Specimen Height)/(Permeability Number*Air Pressure on Wall*Cross-Sectional Area of Specimen)
Permeability Number or Standard Specimen
​ LaTeX ​ Go Permeability Number = 501.28/(Pressure in Casting*Time)

Permeability Number or Standard Specimen Formula

​LaTeX ​Go
Permeability Number = 501.28/(Pressure in Casting*Time)
PN = 501.28/(pc*tp)

What is permeability number?

The Permeability Number the rate of flow of air passing through a standard specimen under a standard pressure.
The standard permeability test is to measure time taken by a 2000 cub cm of air at a pressure typically of 980 Pa (10 g/cm2), to pass through a standard sand specimen confined in a specimen tube. The standard specimen size is 50.8 mm in diameter and a length of 50.8 mm.

How to Calculate Permeability Number or Standard Specimen?

Permeability Number or Standard Specimen calculator uses Permeability Number = 501.28/(Pressure in Casting*Time) to calculate the Permeability Number, The Permeability Number or Standard Specimen is calculated by simply using all the standard parameters in place of formula. The rate of flow of air passing through a standard specimen under a standard pressure is termed as permeability number. Permeability Number is denoted by PN symbol.

How to calculate Permeability Number or Standard Specimen using this online calculator? To use this online calculator for Permeability Number or Standard Specimen, enter Pressure in Casting (pc) & Time (tp) and hit the calculate button. Here is how the Permeability Number or Standard Specimen calculation can be explained with given input values -> 4.368917 = 501.28/(38.2459349999973*3).

FAQ

What is Permeability Number or Standard Specimen?
The Permeability Number or Standard Specimen is calculated by simply using all the standard parameters in place of formula. The rate of flow of air passing through a standard specimen under a standard pressure is termed as permeability number and is represented as PN = 501.28/(pc*tp) or Permeability Number = 501.28/(Pressure in Casting*Time). Pressure in Casting is the force applied to the molten metal during the casting process, which can affect the flow, filling, and solidification of the material & Time is various stages and durations throughout the casting process.
How to calculate Permeability Number or Standard Specimen?
The Permeability Number or Standard Specimen is calculated by simply using all the standard parameters in place of formula. The rate of flow of air passing through a standard specimen under a standard pressure is termed as permeability number is calculated using Permeability Number = 501.28/(Pressure in Casting*Time). To calculate Permeability Number or Standard Specimen, you need Pressure in Casting (pc) & Time (tp). With our tool, you need to enter the respective value for Pressure in Casting & Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Permeability Number?
In this formula, Permeability Number uses Pressure in Casting & Time. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Permeability Number = (Volume of Air in Casting*Height of Specimen)/(Air Pressure on Wall*Cross-Sectional Area of Specimen*Time)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!