Peak Rate of Runoff in Rational Formula Solution

STEP 0: Pre-Calculation Summary
Formula Used
Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36
QR = (Cr*Ac*Pc)/36
This formula uses 4 Variables
Variables Used
Peak Drainage Discharge by Rational Formula - (Measured in Cubic Meter per Second) - The Peak Drainage Discharge by Rational Formula estimates stormwater runoff using parameters such as rainfall intensity, catchment area, and runoff coefficient to determine the maximum flow rate.
Runoff Coefficient - Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
Area of Catchment - (Measured in Square Meter) - Area of Catchment refers to the area of land where all water flows to a single stream, river, lake or even ocean.
Critical Rainfall Intensity - (Measured in Centimeter per Hour) - Critical Rainfall Intensity is the precipitation rate at which surface runoff initiates, leading to increased risk of flooding or other hydrological hazards.
STEP 1: Convert Input(s) to Base Unit
Runoff Coefficient: 0.5 --> No Conversion Required
Area of Catchment: 15 Hectare --> 150000 Square Meter (Check conversion ​here)
Critical Rainfall Intensity: 2.01 Centimeter per Hour --> 2.01 Centimeter per Hour No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
QR = (Cr*Ac*Pc)/36 --> (0.5*150000*2.01)/36
Evaluating ... ...
QR = 4187.5
STEP 3: Convert Result to Output's Unit
4187.5 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
4187.5 Cubic Meter per Second <-- Peak Drainage Discharge by Rational Formula
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Peak Drainage Discharge by Rational Formula Calculators

Catchment Area given Peak Rate of Runoff and Rainfall Intensity
​ LaTeX ​ Go Area of Catchment = (36*Peak Drainage Discharge by Rational Formula)/(Runoff Coefficient*Critical Rainfall Intensity)
Critical Rainfall Intensity for Peak Rate of Runoff
​ LaTeX ​ Go Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient)
Coefficient of Runoff given Peak Rate of Runoff
​ LaTeX ​ Go Runoff Coefficient = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Critical Rainfall Intensity)
Peak Rate of Runoff in Rational Formula
​ LaTeX ​ Go Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36

Peak Rate of Runoff in Rational Formula Formula

​LaTeX ​Go
Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36
QR = (Cr*Ac*Pc)/36

What is Peak Runoff ?

Peak Runoff, also known as peak discharge, is the maximum rate of flow during a storm event. It is a critical factor in designing storm water management systems, such as culverts, storm sewers, and detention basins. Several methods can be used to calculate peak rate runoff, including empirical formulas and hydrologic modeling.

How to Calculate Peak Rate of Runoff in Rational Formula?

Peak Rate of Runoff in Rational Formula calculator uses Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36 to calculate the Peak Drainage Discharge by Rational Formula, The Peak Rate of Runoff in Rational Formula is defined as the maximum rate of flow during a storm event. It is a critical factor in designing storm water management systems, such as culverts, storm sewers, and detention basins. Peak Drainage Discharge by Rational Formula is denoted by QR symbol.

How to calculate Peak Rate of Runoff in Rational Formula using this online calculator? To use this online calculator for Peak Rate of Runoff in Rational Formula, enter Runoff Coefficient (Cr), Area of Catchment (Ac) & Critical Rainfall Intensity (Pc) and hit the calculate button. Here is how the Peak Rate of Runoff in Rational Formula calculation can be explained with given input values -> 4187.5 = (0.5*150000*5.58333333333333E-06)/36.

FAQ

What is Peak Rate of Runoff in Rational Formula?
The Peak Rate of Runoff in Rational Formula is defined as the maximum rate of flow during a storm event. It is a critical factor in designing storm water management systems, such as culverts, storm sewers, and detention basins and is represented as QR = (Cr*Ac*Pc)/36 or Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36. Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received, Area of Catchment refers to the area of land where all water flows to a single stream, river, lake or even ocean & Critical Rainfall Intensity is the precipitation rate at which surface runoff initiates, leading to increased risk of flooding or other hydrological hazards.
How to calculate Peak Rate of Runoff in Rational Formula?
The Peak Rate of Runoff in Rational Formula is defined as the maximum rate of flow during a storm event. It is a critical factor in designing storm water management systems, such as culverts, storm sewers, and detention basins is calculated using Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36. To calculate Peak Rate of Runoff in Rational Formula, you need Runoff Coefficient (Cr), Area of Catchment (Ac) & Critical Rainfall Intensity (Pc). With our tool, you need to enter the respective value for Runoff Coefficient, Area of Catchment & Critical Rainfall Intensity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!